Nejvíce citovaný článek - PubMed ID 26071600
OBJECTIVES: The objective of this post hoc analysis was to analyze real-world dual antiplatelet therapy (DAPT) regimens following polymer-free sirolimus-eluting stent (PF-SES) implantations in an unselected patient population. METHODS: Patient-level data from two all-comers observational studies (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled and analyzed in terms of their primary endpoint. During the data verification process, we observed substantial deviations from DAPT guideline recommendations. To illuminate this gap between clinical practice and guideline recommendations, we conducted a post hoc analysis of DAPT regimens and clinical event rates for which we defined the net adverse event rate (NACE) consisting of target lesion revascularization (TLR, primary endpoint of all-comers observational studies) all-cause death, myocardial infarction (MI), stent thrombosis (ST), and bleeding events. A logistic regression was utilized to determine predictors why ticagrelor was used in stable coronary artery disease (CAD) patients instead of the guideline-recommended clopidogrel. RESULTS: For stable CAD, the composite endpoint of clinical, bleeding, and stent thrombosis, i.e., NACE, between the clopidogrel and ticagrelor treatment groups was not different (5.4% vs. 5.1%, p = 0.745). Likewise, in the acute coronary syndrome (ACS) cohort, the NACE rates were not different between both DAPT strategies (9.2% vs. 9.3%, p = 0.927). There were also no differences in the accumulated rates for TLR, myocardial infarction ([MI], mortality, bleeding events, and stent thrombosis in elective and ACS patients. The main predictors for ticagrelor use in stable CAD patients were age < 65 years, smaller vessels, treatment of ostial and calcified lesions, and in-stent restenosis. CONCLUSION: Within the framework of a post hoc analysis based on a real-world, large cohort study, there were no differences in the combined endpoint of major adverse cardiac events (MACE), bleeding and thrombotic events for clopidogrel and ticagrelor in stable CAD or ACS patients. Despite the recommendation for clopidogrel by the European Society of Cardiology (ESC), real-world ticagrelor use was observed in subgroups of stable CAD patients that ought to be explored in future trials.
- Klíčová slova
- Clopidogrel, Dual antiplatelet therapy, Polymer-free, Sirolimus-eluting stent, Ticagrelor,
- MeSH
- časové faktory MeSH
- dodržování směrnic MeSH
- duální protidestičková léčba * škodlivé účinky mortalita MeSH
- hodnocení rizik MeSH
- inhibitory agregace trombocytů aplikace a dávkování škodlivé účinky MeSH
- kardiovaskulární látky aplikace a dávkování škodlivé účinky MeSH
- koronární angioplastika škodlivé účinky přístrojové vybavení mortalita MeSH
- koronární trombóza etiologie prevence a kontrola MeSH
- krvácení chemicky indukované MeSH
- lékařská praxe - způsoby provádění MeSH
- lidé středního věku MeSH
- lidé MeSH
- multicentrické studie jako téma MeSH
- nemoci koronárních tepen diagnostické zobrazování mortalita terapie MeSH
- pozorovací studie jako téma MeSH
- protézy - design MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- sirolimus aplikace a dávkování škodlivé účinky MeSH
- směrnice pro lékařskou praxi jako téma MeSH
- stenty uvolňující léky * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- inhibitory agregace trombocytů MeSH
- kardiovaskulární látky MeSH
- sirolimus MeSH
BACKGROUND: Stent thrombosis (ST) is a serious complication following coronary stenting. Intravascular optical coherence tomography (OCT) may provide insights into mechanistic processes leading to ST. We performed a prospective, multicenter study to evaluate OCT findings in patients with ST. METHODS: Consecutive patients presenting with ST were prospectively enrolled in a registry by using a centralized telephone registration system. After angiographic confirmation of ST, OCT imaging of the culprit vessel was performed with frequency domain OCT. Clinical data were collected according to a standardized protocol. OCT acquisitions were analyzed at a core laboratory. Dominant and contributing findings were adjudicated by an imaging adjudication committee. RESULTS: Two hundred thirty-one patients presenting with ST underwent OCT imaging; 14 (6.1%) had image quality precluding further analysis. Of the remaining patients, 62 (28.6%) and 155 (71.4%) presented with early and late/very late ST, respectively. The underlying stent type was a new-generation drug-eluting stent in 50.3%. Mean reference vessel diameter was 2.9±0.6 mm and mean reference vessel area was 6.8±2.6 mm2. Stent underexpansion (stent expansion index <0.8) was observed in 44.4% of patients. The predicted average probability (95% confidence interval) that any frame had uncovered (or thrombus-covered) struts was 99.3% (96.1-99.9), 96.6% (92.4-98.5), 34.3% (15.0-60.7), and 9.6% (6.2-14.5) and malapposed struts was 21.8% (8.4-45.6), 8.5% (4.6-15.3), 6.7% (2.5-16.3), and 2.0% (1.2-3.3) for acute, subacute, late, and very late ST, respectively. The most common dominant finding adjudicated for acute ST was uncovered struts (66.7% of cases); for subacute ST, the most common dominant finding was uncovered struts (61.7%) and underexpansion (25.5%); for late ST, the most common dominant finding was uncovered struts (33.3%) and severe restenosis (19.1%); and for very late ST, the most common dominant finding was neoatherosclerosis (31.3%) and uncovered struts (20.2%). In patients presenting very late ST, uncovered stent struts were a common dominant finding in drug-eluting stents, and neoatherosclerosis was a common dominant finding in bare metal stents. CONCLUSIONS: In patients with ST, uncovered and malapposed struts were frequently observed with the incidence of both decreasing with longer time intervals between stent implantation and presentation. The most frequent dominant observation varied according to time intervals from index stenting: uncovered struts and underexpansion in acute/subacute ST and neoatherosclerosis and uncovered struts in late/very late ST.
- Klíčová slova
- atherosclerosis, malapposition, stents, thrombosis, tomography, optical coherence, uncovered struts,
- MeSH
- koronární angioplastika škodlivé účinky trendy MeSH
- koronární trombóza diagnostické zobrazování epidemiologie prevence a kontrola MeSH
- lidé MeSH
- optická koherentní tomografie metody trendy MeSH
- prospektivní studie MeSH
- registrace MeSH
- senioři MeSH
- stenty uvolňující léky škodlivé účinky trendy MeSH
- výzkumná zpráva trendy MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Evropa epidemiologie MeSH