Most cited article - PubMed ID 27250348
Feasibility of ultra low-dose thallium stress-redistribution protocol including prone imaging in obese patients using CZT camera
The purpose of this study was to assess the prognostic value of ultra-low dose thallium myocardial perfusion imaging. Three hundred and sixty-six patients (245 men) underwent ultra-low dose stress-redistribution imaging on CZT SPECT camera GE Discovery NM 530c. The stress test was performed by bicycle ergometry or regadenoson injection. The activity of 0.5 MBq (0.014 mCi) Tl-201 chloride per kilogram of body weight was administered. The stress images were acquired immediately and redistribution images were taken after 3 h. Patient follow-up was focused on combined end-point (death, myocardial infarction, unstable angina, revascularization and hospitalization for heart failure). Data analysis was performed from hospital database, with a mean period 23 months. Patients with revascularization within 1 month after SPECT was excluded as revascularization for diagnosis. Ischaemia on SPECT was found in 72 patients, 294 patients were without ischaemia. In patients with ischaemia there were 21 (29.2%) subjects with cardiac events, and 23 (7.9%) in patients without ischaemia (HR 4.15, 95% CI 2.30-7.51, p < 0.0001). Ultra-low dose thallium perfusion imaging using CZT camera provides very good prognostic results in assessment of myocardial ischaemia.
- Keywords
- CZT, Low-dose, Myocardial perfusion, Prognostic value, SPECT, Thallium,
- MeSH
- Time Factors MeSH
- Radiation Dosage * MeSH
- Equipment Design MeSH
- Gamma Cameras * MeSH
- Myocardial Ischemia diagnostic imaging mortality physiopathology therapy MeSH
- Tomography, Emission-Computed, Single-Photon adverse effects instrumentation methods MeSH
- Cadmium * MeSH
- Coronary Circulation * MeSH
- Middle Aged MeSH
- Humans MeSH
- Pilot Projects MeSH
- Predictive Value of Tests MeSH
- Prognosis MeSH
- Disease Progression MeSH
- Purines administration & dosage MeSH
- Pyrazoles administration & dosage MeSH
- Radiation Exposure adverse effects prevention & control MeSH
- Radiopharmaceuticals administration & dosage adverse effects MeSH
- Thallium Radioisotopes administration & dosage adverse effects MeSH
- Reproducibility of Results MeSH
- Aged MeSH
- Tellurium * MeSH
- Vasodilator Agents administration & dosage MeSH
- Exercise Test MeSH
- Zinc * MeSH
- Myocardial Perfusion Imaging adverse effects instrumentation methods MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Names of Substances
- CdZnTe MeSH Browser
- Cadmium * MeSH
- Purines MeSH
- Pyrazoles MeSH
- Radiopharmaceuticals MeSH
- Thallium Radioisotopes MeSH
- regadenoson MeSH Browser
- Tellurium * MeSH
- Thallium-201 MeSH Browser
- Vasodilator Agents MeSH
- Zinc * MeSH