The prognostic value of ultra low-dose thallium myocardial perfusion protocol using CZT SPECT
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu časopisecké články
Grantová podpora
LQ1605 from the National Program of Sustainability II (MEYS CR)
Ministerstvo Školství, Mládeže a Tělovýchovy
PubMed
30680654
DOI
10.1007/s10554-019-01535-7
PII: 10.1007/s10554-019-01535-7
Knihovny.cz E-zdroje
- Klíčová slova
- CZT, Low-dose, Myocardial perfusion, Prognostic value, SPECT, Thallium,
- MeSH
- časové faktory MeSH
- dávka záření * MeSH
- design vybavení MeSH
- gama kamery * MeSH
- ischemická choroba srdeční diagnostické zobrazování mortalita patofyziologie terapie MeSH
- jednofotonová emisní výpočetní tomografie škodlivé účinky přístrojové vybavení metody MeSH
- kadmium * MeSH
- koronární cirkulace * MeSH
- lidé středního věku MeSH
- lidé MeSH
- pilotní projekty MeSH
- prediktivní hodnota testů MeSH
- prognóza MeSH
- progrese nemoci MeSH
- puriny aplikace a dávkování MeSH
- pyrazoly aplikace a dávkování MeSH
- radiační expozice škodlivé účinky prevence a kontrola MeSH
- radiofarmaka aplikace a dávkování škodlivé účinky MeSH
- radioizotopy thallia aplikace a dávkování škodlivé účinky MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- telur * MeSH
- vazodilatancia aplikace a dávkování MeSH
- zátěžový test MeSH
- zinek * MeSH
- zobrazování myokardiální perfuze škodlivé účinky přístrojové vybavení metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- CdZnTe MeSH Prohlížeč
- kadmium * MeSH
- puriny MeSH
- pyrazoly MeSH
- radiofarmaka MeSH
- radioizotopy thallia MeSH
- regadenoson MeSH Prohlížeč
- telur * MeSH
- Thallium-201 MeSH Prohlížeč
- vazodilatancia MeSH
- zinek * MeSH
The purpose of this study was to assess the prognostic value of ultra-low dose thallium myocardial perfusion imaging. Three hundred and sixty-six patients (245 men) underwent ultra-low dose stress-redistribution imaging on CZT SPECT camera GE Discovery NM 530c. The stress test was performed by bicycle ergometry or regadenoson injection. The activity of 0.5 MBq (0.014 mCi) Tl-201 chloride per kilogram of body weight was administered. The stress images were acquired immediately and redistribution images were taken after 3 h. Patient follow-up was focused on combined end-point (death, myocardial infarction, unstable angina, revascularization and hospitalization for heart failure). Data analysis was performed from hospital database, with a mean period 23 months. Patients with revascularization within 1 month after SPECT was excluded as revascularization for diagnosis. Ischaemia on SPECT was found in 72 patients, 294 patients were without ischaemia. In patients with ischaemia there were 21 (29.2%) subjects with cardiac events, and 23 (7.9%) in patients without ischaemia (HR 4.15, 95% CI 2.30-7.51, p < 0.0001). Ultra-low dose thallium perfusion imaging using CZT camera provides very good prognostic results in assessment of myocardial ischaemia.
Department of Nuclear Medicine Masaryk Memorial Cancer Center Brno Czech Republic
Department of Nuclear Medicine University Hospital Olomouc Palacky University Olomouc Czech Republic
Department of Pathological Physiology Faculty of Medicine Masaryk University Brno Czech Republic
Zobrazit více v PubMed
J Nucl Cardiol. 2004 Mar-Apr;11(2):171-85 PubMed
Nucl Med Commun. 2012 May;33(5):464-9 PubMed
Eur J Nucl Med Mol Imaging. 2014 May;41(5):956-62 PubMed
Circ J. 2014;78(11):2727-34 PubMed
J Nucl Cardiol. 2016 Feb;23(1):11-20 PubMed
Eur J Nucl Med Mol Imaging. 2015 Nov;42(12):1929-40 PubMed
Int J Cardiovasc Imaging. 2016 Sep;32(9):1463-1469 PubMed
J Nucl Cardiol. 2018 Feb;25(1):249-256 PubMed
J Nucl Med. 2017 Sep;58(9):1459-1463 PubMed
Int J Cardiovasc Imaging. 2017 Dec;33(12):2049-2056 PubMed
J Nucl Cardiol. 2018 Feb;25(1):26-35 PubMed
J Cardiol. 2018 Feb;71(2):174-180 PubMed
J Nucl Cardiol. 2018 Jan 29;:null PubMed
Circulation. 1998 Feb 17;97(6):535-43 PubMed