Nejvíce citovaný článek - PubMed ID 31355343
Implantation of Scharioth macula lens in patients with age-related macular degeneration: results of a prospective European multicentre clinical trial
INTRODUCTION: The objective of this prospective study was to evaluate the effects of intraocular macular lens implantation and visual rehabilitation on the quality of life of patients with geographic atrophy (GA) secondary to age-related macular degeneration (AMD). METHODS: Patients with bilaterally decreased near vision (not better than 0.3 logMAR with the best correction), pseudophakia, were included in the project. The Scharioth macula lens (SML) was implanted into the patients' better-seeing eye. Intensive visual rehabilitation of the ability to perform nearby activities was performed for 20 consecutive postoperative days. All subjects were examined before and after SML implantation ophthalmologically. The National Eye Institute 25-Item Visual Function Questionnaire (NEI VFQ-25) was administered before and 6 months after surgery. RESULTS: Twenty eligible patients with mean age 81 years (63 to 92 years) were included in the project: 7 males and 13 females. Nineteen of them completed the 6-month follow-up. Near uncorrected visual acuity was 1.321 ± 0.208 logMAR before SML implantation and improved to 0.547 ± 0.210 logMAR after 6 months (dz = - 2.846, p < 0.001, BF10 = 3.29E + 07). In the composite score of the NEI VFQ-25, there was an improvement in the general score and the specific domains related to the implantation. Participants reported fewer difficulties in performing near activities (dz = 0.91, p = 0.001, BF10 = 39.718) and upturns in mental health symptoms related to vision (dz = 0.62, p = .014, BF10 = 3.937). CONCLUSION: SML implantation, followed by appropriate rehabilitation, improved near vision and increased the quality of life of visually handicapped patients with AMD in our project.
- Klíčová slova
- Age-related macular degeneration, Near vision, Quality of life, Scharioth macula lens,
- MeSH
- geografická atrofie * diagnóza etiologie MeSH
- kvalita života MeSH
- lidé MeSH
- makulární degenerace * komplikace diagnóza MeSH
- nitrooční čočky * MeSH
- prospektivní studie MeSH
- průzkumy a dotazníky MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: For patients with age-related macular degeneration (AMD), a special intraocular lens implantation partially compensates for the loss in the central part of the visual field. For six months, we evaluated changes in neurophysiological parameters in patients implanted with a "Scharioth macula lens" (SML; a center near high add + 10 D and peripheral plano carrier bifocal lens designed to be located between the iris and an artificial lens). METHODS: Fourteen patients (5 M, 9 F, 63-87 years) with dry AMD were examined prior to and at 3 days after, as well as 1, 2, and 6 months after, implantation using pattern-reversal, motion-onset, and cognitive evoked potentials, psychophysical tests evaluating distant and near visual acuity, and contrast sensitivity. RESULTS: Near visual acuity without an external aid was significantly better six months after implantation than before implantation (Jaeger table median (lower; upper quartile): 4 (1; 6) vs. 15 (13; 17)). Distant visual acuity was significantly altered between the pre- (0.7 (0.5; 0.8) logMAR) and last postimplantation visits (0.8 (0.7; 0.8) logMAR), which matched prolongation of the P100 peak time (147 (135; 151) ms vs. 161 (141; 166) ms) of 15 arc min pattern-reversal VEPs and N2 peak time (191.5 (186.5; 214.5) ms vs. 205 (187; 218) ms) of peripheral motion-onset VEPs. CONCLUSION: SML implantation significantly improved near vision. We also observed a slight but significant decrease in distant and peripheral vision. The most efficient electrophysiological approach to test patients with SML was the peripheral motion-onset stimulation, which evoked repeatable and readable VEPs.
- Klíčová slova
- Age-related macular degeneration, Maculopathy, Motion-onset VEPs, Oddball ERPs, P3b, Pattern-reversal VEPs, Scharioth macular lens,
- MeSH
- elektroretinografie MeSH
- implantace nitrooční čočky MeSH
- lidé MeSH
- makulární degenerace * MeSH
- nitrooční čočky * MeSH
- zraková ostrost MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH