Nejvíce citovaný článek - PubMed ID 32045008
AIMS: We hypothesized that during left bundle branch (LBB) area pacing, the various possible combinations of direct capture/non-capture of the septal myocardium and the LBB result in distinct patterns of right and left ventricular activation. This could translate into different combinations of R-wave peak time (RWPT) in V1 and V6. Consequently, the V6-V1 interpeak interval could differentiate the three types of LBB area capture: non-selective (ns-)LBB, selective (s-)LBB, and left ventricular septal (LVS). METHODS AND RESULTS: Patients with unquestionable evidence of LBB capture were included. The V6-V1 interpeak interval, V6RWPT, and V1RWPT were compared between different types of LBB area capture. A total of 468 patients from two centres were screened, with 124 patients (239 electrocardiograms) included in the analysis. Loss of LVS capture resulted in an increase in V1RWPT by ≥15 ms but did not impact V6RWPT. Loss of LBB capture resulted in an increase in V6RWPT by ≥15 ms but only minimally influenced V1RWPT. Consequently, the V6-V1 interval was longest during s-LBB capture (62.3 ± 21.4 ms), intermediate during ns-LBB capture (41.3 ± 14.0 ms), and shortest during LVS capture (26.5 ± 8.6 ms). The optimal value of the V6-V1 interval value for the differentiation between ns-LBB and LVS capture was 33 ms (area under the receiver operating characteristic curve of 84.7%). A specificity of 100% for the diagnosis of LBB capture was obtained with a cut-off value of >44 ms. CONCLUSION: The V6-V1 interpeak interval is a promising novel criterion for the diagnosis of LBB area capture.
- Klíčová slova
- Conduction system pacing, Electrocardiogram, Left bundle branch capture, Left bundle branch pacing, Left ventricular septal capture,
- MeSH
- elektrokardiografie metody MeSH
- Hisův svazek * MeSH
- kardiostimulace umělá metody MeSH
- lidé MeSH
- mezikomorová přepážka * MeSH
- převodní systém srdeční MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Left bundle branch area pacing (LBBAP) has recently been introduced as a novel physiological pacing strategy. Within LBBAP, distinction is made between left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP, no left bundle capture). OBJECTIVE: To investigate acute electrophysiological effects of LBBP and LVSP as compared to intrinsic ventricular conduction. METHODS: Fifty patients with normal cardiac function and pacemaker indication for bradycardia underwent LBBAP. Electrocardiography (ECG) characteristics were evaluated during pacing at various depths within the septum: starting at the right ventricular (RV) side of the septum: the last position with QS morphology, the first position with r' morphology, LVSP and-in patients where left bundle branch (LBB) capture was achieved-LBBP. From the ECG's QRS duration and QRS morphology in lead V1, the stimulus- left ventricular activation time left ventricular activation time (LVAT) interval were measured. After conversion of the ECG into vectorcardiogram (VCG) (Kors conversion matrix), QRS area and QRS vector in transverse plane (Azimuth) were determined. RESULTS: QRS area significantly decreased from 82 ± 29 µVs during RV septal pacing (RVSP) to 46 ± 12 µVs during LVSP. In the subgroup where LBB capture was achieved (n = 31), QRS area significantly decreased from 46 ± 17 µVs during LVSP to 38 ± 15 µVs during LBBP, while LVAT was not significantly different between LVSP and LBBP. In patients with normal ventricular activation and narrow QRS, QRS area during LBBP was not significantly different from that during intrinsic activation (37 ± 16 vs. 35 ± 19 µVs, respectively). The Azimuth significantly changed from RVSP (-46 ± 33°) to LVSP (19 ± 16°) and LBBP (-22 ± 14°). The Azimuth during both LVSP and LBBP were not significantly different from normal ventricular activation. QRS area and LVAT correlated moderately (Spearman's R = 0.58). CONCLUSIONS: ECG and VCG indices demonstrate that both LVSP and LBBP improve ventricular dyssynchrony considerably as compared to RVSP, to values close to normal ventricular activation. LBBP seems to result in a small, but significant, improvement in ventricular synchrony as compared to LVSP.
- Klíčová slova
- bradycardia pacing, cardiac resynchronization therapy, left bundle branch area pacing,
- Publikační typ
- časopisecké články MeSH