TTE, transthoracic echocardiography Dotaz Zobrazit nápovědu
OBJECTIVE: Patent foramen ovale (PFO) can be detected in up to 43% of patients with cryptogenic cerebral ischemia undergoing investigation with transesophageal echocardiography (TEE). The diagnostic value of transthoracic echocardiography (TTE) in the detection of PFO in patients with cryptogenic ischemic stroke or transient ischemic attack has not been compared with that of transcranial Doppler (TCD) using a comprehensive meta-analytical approach. METHODS: We performed a systematic literature review to identify all prospective observational studies of patients with cryptogenic cerebral ischemia that provided both sensitivity and specificity measures of TTE, TCD, or both compared to the gold standard of TEE. RESULTS: Our literature search identified 35 eligible studies including 3,067 patients. The pooled sensitivity and specificity for TCD was 96.1% (95% confidence interval [CI] = 93.0-97.8%) and 92.4% (95% CI = 85.5-96.1%), whereas the respective measures for TTE were 45.1% (95% CI = 30.8-60.3%) and 99.6% (95% CI = 96.5-99.9%). TTE was superior in terms of higher positive likelihood ratio values (LR+ = 106.61, 95% CI = 15.09-753.30 for TTE vs LR+ = 12.62, 95% CI = 6.52-24.43 for TCD; p = 0.043), whereas TCD demonstrated lower negative likelihood values (LR- = 0.04, 95% CI = 0.02-0.08) compared to TTE (LR- = 0.55, 95% CI = 0.42-0.72; p < 0.001). Finally, the area under the summary receiver operating curve (AUC) was significantly greater (p < 0.001) in TCD (AUC = 0.98, 95% CI = 0.97-0.99) compared to TTE studies (AUC = 0.86, 95% CI = 0.82-0.89). INTERPRETATION: TCD is more sensitive but less specific compared to TTE for the detection of PFO in patients with cryptogenic cerebral ischemia. The overall diagnostic yield of TCD appears to outweigh that of TTE.
- MeSH
- echokardiografie normy MeSH
- foramen ovale apertum diagnostické zobrazování MeSH
- ischemie mozku diagnostické zobrazování MeSH
- lidé MeSH
- senzitivita a specificita * MeSH
- ultrasonografie dopplerovská transkraniální normy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- srovnávací studie MeSH
- systematický přehled MeSH
OBJECTIVES: Stroke volume (SV) and cardiac output monitoring is a cornerstone of hemodynamic assessment. Noninvasive technologies are increasingly used in children. This study compared SV measurements obtained by transcutaneous Doppler ultrasound techniques (ultrasonic cardiac output monitor [USCOM]), transthoracic echocardiography jugular (TTE-J), and parasternal (TTE-P) views performed by pediatric intensivists (OP-As) with limited training in cardiac sonography (20 previous examinations) and pediatric cardiologists (OP-Bs) with limited training in USCOM (30 previous examinations) in spontaneously ventilating children. METHODS: A single-center study was conducted in 37 children. Each operator obtained 3 sets of USCOM SV measurements within a period of 3 to 5 minutes, followed with TTE measurements from both apical and jugular views. The investigators were blinded to each other's results to prevent visual and auditory bias. RESULTS: Both USCOM and TTE methods were applicable in 89% of patients. The intraobserver variability of USCOM, TTE-J, and TTE-P were less than 10% in both investigators. The SV measurements by OP-As using USCOM, TTE-J, and TTE-P were 46.15 (25.48) mL, 39.45 (20.65) mL, and 33.42 (16.69) mL, respectively. The SV measurements by OP-Bs using USCOM, TTE-J, and TTE-P were 43.99 (25.24) mL, 38.91 (19.98) mL, and 37.58 (19.81) mL, respectively.The percentage error in SV with USCOM relative to TTE-J was 36% in OP-As and 37% in OP-Bs. The percentage error in SV with TTE-P was 33% relative to TTE-J in OP-As and 21% in OP-Bs. CONCLUSIONS: Our findings show that the methods are not interchangeable because SV values by USCOM are higher in comparison with the SV values obtained by TTE. Both methods have low level of intraobserver variability. The SV measurements obtained by TTE-P were significantly lower compared with the TTE-J for the operator with limited training in echocardiography. The TTE-P requires longer practice compared with the TTE-J; therefore, we recommend to prefer TTE-J to TTE-P for inexperienced operators.
Anticoagulant therapy is recommended for the secondary prevention of stroke in patients with atrial fibrillation (AF). T he identification of patients at high risk for early recurrence, which are potential candidates to prompt anticoagulation, is crucial to justify the risk of bleeding associated with early anticoagulant treatment. The aim of this study was to evaluate in patients with acute ischemic stroke and AF the association between findings at trans-thoracic echocardiography (TTE) and 90 days recurrence. In consecutive patients with acute ischemic stroke and AF, TTE was performed within 7 days from hospital admission. Study outcomes were recurrent ischemic cerebrovascular events (stroke or TIA) and systemic embolism. 854 patients (mean age 76.3 ± 9.5 years) underwent a TTE evaluation; 63 patients (7.4%) had at least a study outcome event. Left atrial thrombosis was present in 11 patients (1.3%) among whom 1 had recurrent ischemic event. Left atrial enlargement was present in 548 patients (64.2%) among whom 51 (9.3%) had recurrent ischemic events. The recurrence rate in the 197 patients with severe left atrial enlargement was 11.7%. On multivariate analysis, the presence of atrial enlargement (OR 2.13; 95% CI 1.06-4.29, p = 0.033) and CHA2DS2-VASc score (OR 1.22; 95% CI 1.04-1.45, p = 0.018, for each point increase) were correlated with ischemic recurrences. In patients with AF-associated acute stroke, left atrial enlargement is an independent marker of recurrent stroke and systemic embolism. The risk of recurrence is accounted for by severe atrial enlargement. TTE-detected left atrial thrombosis is relatively uncommon.
- Klíčová slova
- Acute stroke, Atrial fibrillation, Echocardiography, Outcome,
- MeSH
- cévní mozková příhoda diagnostické zobrazování etiologie prevence a kontrola MeSH
- echokardiografie MeSH
- fibrilace síní komplikace diagnostické zobrazování MeSH
- lidé MeSH
- prognóza MeSH
- recidiva MeSH
- rizikové faktory MeSH
- sekundární prevence metody MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Catheter ablation of ventricular tachycardia (VT) in patients with structural heart disease (SHD) is effective in prevention of arrhythmia recurrences. However, endocardial ablation may be challenging in the presence of organized left ventricular (LV) endocavitary thrombus. Our goal was to analyze the results of VT ablation in patients with identified old thrombus. METHODS AND RESULTS: We reviewed clinical and procedural data of 344 consecutive patients who underwent VT ablation for SHD. Old endocavitary thrombus was identified in four patients by preprocedural transthoracic echocardiography (TTE) and in four more patients by intracardiac echocardiography (ICE). All together, the case series of eight patients with detectable thrombus is reported. All patients (one woman, age: 67 ± 7 years) had postinfarction aneurysm (20 ± 8 years after the index myocardial infarction) and the thrombus was well organized without mobile structures. Arrhythmogenic substrate could not be obviously targeted beneath the base of thrombus; however, catheter ablation was successfully performed in the close vicinity. A total of 2.4 ± 1.2 procedures were necessary to abolish VT recurrences. Epicardial ablation was performed in three of eight (38%) patients as a second elective procedure. No procedural or periprocedural complications were observed. During the follow-up of 14 ± 15 months, two patients (25%) had sporadic VT recurrences. CONCLUSIONS: ICE seems to be more sensitive for the detection of LV thrombi compared to TTE and is helpful in real-time navigation of mapping/ablation catheter. Besides potential thromboembolic risk, large thrombus may prevent accessibility to the "critical" portion of arrhythmia circuit and epicardial ablation is required in selected cases.
- Klíčová slova
- catheter ablation, thrombus, ventricular tachycardia,
- MeSH
- časové faktory MeSH
- chirurgie s pomocí počítače * MeSH
- echokardiografie * MeSH
- kardiochirurgické výkony metody MeSH
- katetrizační ablace metody MeSH
- komorová tachykardie komplikace chirurgie MeSH
- lidé MeSH
- nemoci srdce komplikace MeSH
- retrospektivní studie MeSH
- senioři MeSH
- trombóza komplikace MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIM: Vericiguat significantly reduced the primary composite outcome of heart failure (HF) hospitalization or cardiovascular death in the VICTORIA trial. It is unknown if these outcome benefits are related to reverse left ventricular (LV) remodelling with vericiguat in patients with HF with reduced ejection fraction (HFrEF). The aim of this study was to compare the effects of vericiguat versus placebo on LV structure and function after 8 months of therapy in patients with HFrEF. METHODS AND RESULTS: Standardized transthoracic echocardiography (TTE) was performed at baseline and after 8 months of therapy in a subset of HFrEF patients in VICTORIA. The co-primary endpoints were changes in LV end-systolic volume index (LVESVI) and LV ejection fraction (LVEF). Quality assurance and central reading were performed by an echocardiographic core laboratory blinded to treatment assignment. A total of 419 patients (208 vericiguat, 211 placebo) with high-quality paired TTE at baseline and 8 months were included. Baseline clinical characteristics were well balanced between treatment groups and echocardiographic characteristics were representative of patients with HFrEF. LVESVI significantly declined (60.7 ± 26.8 to 56.8 ± 30.4 ml/m2 ; p < 0.01) and LVEF significantly increased (33.0 ± 9.4% to 36.1 ± 10.2%; p < 0.01) in the vericiguat group, but similarly in the placebo group (absolute changes for vericiguat vs. placebo: LVESVI -3.8 ± 15.4 vs. -7.1 ± 20.5 ml/m2 ; p = 0.07 and LVEF +3.2 ± 8.0% vs. +2.4 ± 7.6%; p = 0.31). The absolute rate per 100 patient-years of the primary composite endpoint at 8 months tended to be lower in the vericiguat group (19.8) than the placebo group (29.6) (p = 0.07). CONCLUSIONS: In this pre-specified echocardiographic study, significant improvements in LV structure and function occurred over 8 months in both vericiguat and placebo in a high-risk HFrEF population with recent worsening HF. Further studies are warranted to define the mechanisms of vericiguat's benefit in HFrEF.
- Klíčová slova
- Echocardiography, Heart failure with reduced ejection fraction, Left ventricular function, Left ventricular structure, Vericiguat,
- MeSH
- echokardiografie MeSH
- funkce levé komory srdeční MeSH
- heterocyklické sloučeniny bicyklické * MeSH
- lidé MeSH
- srdeční selhání * diagnostické zobrazování farmakoterapie chemicky indukované MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- heterocyklické sloučeniny bicyklické * MeSH
- vericiguat MeSH Prohlížeč
BACKGROUND: Pulmonary embolism (PE) is a common and potentially life-threatening diagnosis when a certain amount of thrombotic mass obstructs blood flow through the pulmonary circulation. The finding of acute and subacute ischaemic foci on magnetic resonance imaging (MRI) of the brain in a group of patients with this diagnosis in whom we demonstrate the presence of patent foramen ovale (PFO) by transoesophageal echocardiography (TEE) is surprisingly high. METHODS: A total of 129 patients with a diagnosis of pulmonary embolism (confirmed by computed tomography with contrast agent, CTA) who consented to further examination were examined by transthoracic echocardiography (TTE) and transoesophageal echocardiography (TEE) with contrast agent, underwent magnetic resonance imaging of the brain according to a specific protocol, and underwent a comprehensive baseline laboratory examination. RESULTS: In our group of 129 patients, we found the presence of PFO in 36.4% (n=47) of them. A total of 5.4% (n=7) patients had asymptomatic acute and subacute ischaemic changes on brain MRI; 6 of them had concomitant PFO. The statistically significant correlation between troponin levels and the presence of pathological findings on MRI and the trend of a similar correlation for NT-proBNP values is also very interesting finding. CONCLUSIONS: The association between the presence of PFO and the occurrence of symptomatic or asymptomatic findings on brain MRI is a well-known fact (the issue of paradoxical embolism) but the high frequency of acute and subacute lesions on brain MRI in the group of patients with a diagnosis of acute PE is surprising.
- Klíčová slova
- paradoxical embolism, patent foramen ovale, pulmonary embolism, stroke,
- MeSH
- akutní nemoc MeSH
- dospělí MeSH
- echokardiografie transezofageální MeSH
- echokardiografie MeSH
- foramen ovale apertum * komplikace diagnostické zobrazování MeSH
- incidence MeSH
- ischemie mozku diagnostické zobrazování MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie * MeSH
- plicní embolie * diagnostické zobrazování MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
By means of transoesophageal (oesophageal) echocardiography (TEE) the authors examined a group of 20 subjects. In 10 there was clinical suspicion (physical finding, ECG, X-ray) of an atrial septal defect. Common precordial echocardiographic examination (TTE) and dilution of indocyan green by means of an acustic sensing unit were negative or only marginally positive and did not provide a final decision. By means of TEE the defect was confirmed in 8 subjects by the finding of anatomical discontinuity of the septum and the presence of coloured Doppler shunt flow. In two subjects the finding was negative, in 10 controls no pathological findings were detected. The authors confirmed that TEE is a reliable method which proves even slight shunts in the area of the atrial septum. It is probably the most sensitive existing method.
- MeSH
- defekty septa síní diagnóza MeSH
- dospělí MeSH
- echokardiografie * MeSH
- lidé MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
Transthoracic echocardiography (TTE) has become an important modality for the assessment of cardiac structure and function in animal experiments. The acquisition of echocardiographic images in rats requires sedation/anesthesia to keep the rats immobile. Commonly used anesthetic regimens include intraperitoneal or inhalational application of various anesthetics. Several studies have compared the effects of anesthetic agents on echocardiographic parameters in rats; however, none of them examined the effects of different concentrations of inhalational anesthetics on echocardiographic parameters. Accordingly, the aim of this study was to examine the effects of different concentrations of isoflurane used for anesthesia during TTE examination in rats on basic echocardiographic parameters of left ventricular (LV) anatomy and systolic function. TTE examinations were performed in adult male Wistar rats (n=10) anesthetized with isoflurane at concentrations of 1.5-3 %. Standard echocardiograms were recorded for off-line analysis. An absence of changes in basic echocardiographic parameters of LV anatomy and systolic function was found under isoflurane anesthesia using concentrations between 1.5-2.5 %. An isoflurane concentration of 3 % caused a small, but statistically significant, increase in LV chamber dimensions without a concomitant change in heart rate or fractional shortening. For the purpose of TTE examination in the rat, our results suggest that isoflurane concentrations = 2.5 % can be safely recommended.
- MeSH
- anestetika inhalační farmakologie MeSH
- echokardiografie MeSH
- funkce levé komory srdeční účinky léků fyziologie MeSH
- isofluran farmakologie MeSH
- krysa rodu Rattus MeSH
- potkani Wistar MeSH
- srdeční komory diagnostické zobrazování účinky léků MeSH
- systola MeSH
- zvířata MeSH
- Check Tag
- krysa rodu Rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- anestetika inhalační MeSH
- isofluran MeSH
BACKGROUND: Precise determination of the aortic annulus size constitutes an integral part of the preoperative evaluation prior to aortic valve replacement. It enables the estimation of the size of prosthesis to be implanted. Knowledge of the size of the ascending aorta is required in the preoperative analysis and monitoring of its dilation enables the precise timing of the operation. Our goal was to compare the precision of measurement of the aortic annulus and ascending aorta using magnetic resonance (MR), multidetector-row computed tomography (MDCT), transthoracic echocardiography (TTE), and transoesophageal echocardiography (TEE) in patients with degenerative aortic stenosis. METHODS AND RESULTS: A total of 15 patients scheduled to have aortic valve replacement were enrolled into this prospective study. TTE was performed in all patients and was supplemented with TEE, CT and MR in the majority of patients. The values obtained were compared with perioperative measurements. For the measurement of aortic annulus, MR was found to be the most precise technique, followed by MDCT, TTE, and TEE. For the measurement of ascending aorta, MR again was found to be the most precise technique, followed by MDCT, TEE, and TTE. CONCLUSION: In our study, magnetic resonance was found to be the most precise technique for the measurement of aortic annulus and ascending aorta in patients with severe degenerative aortic stenosis.
- MeSH
- aorta diagnostické zobrazování MeSH
- aortální chlopeň diagnostické zobrazování patologie MeSH
- aortální stenóza diagnostické zobrazování MeSH
- chirurgická náhrada chlopně * MeSH
- echokardiografie MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- prospektivní studie MeSH
- rentgendiagnostika MeSH
- senioři MeSH
- velikost orgánu MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
INTRODUCTION: Foam sclerotization of varicose veins may cause paradoxical embolization through patent foramen ovale (PFO). The aim of our study was to: 1) select an optimal screening method for the detection of PFO; 2) determine the prevalence of PFO in a non-selected population; and 3) test the risk of paradoxical embolization of venous bubbles in patients with PFO. MATERIALS AND METHODS: A diver after decompression is a suitable model for determining the risk of paradoxical embolization of venous gas bubbles. 329 Czech divers were screened for PFO. In a pilot study, we compared Transcranial Doppler Sonography (TCD) with Transesophageal Echocardiography (TEE) in 100 patients. TCD alone was used for further screening. In 31 divers with PFO, nitrogen bubbles were detected after simulated dives. Transthoracic Echocardiography (TTE) was used to detect venous bubbles in right-sided heart chambers; TTE and TCD were used to detect arterial bubbles. The right-to-left shunt was rated as non-significant (<20 arterial bubbles) or significant (20 arterial bubbles). Different decompression regimens were compared. RESULTS: In the pilot study, TCD was compared with the gold standard in PFO detection - TEE. The negative predictive value of TCD was 100%, positive predictive value was 92%. Screening was performed in a total of 329 divers, PFO was detected in 85 (25%), significant R-L shunt in 45 (14%). In simulated dive to 50 m maximum depth, venous nitrogen bubbles were detected in 7/8 (88%) divers. In 6/8 (75%) divers, paradoxical embolization was confirmed - nitrogen bubbles were detected in the systemic circulation. CONCLUSION: PFO prevalence with significant R-L shunt was 14% in the non-selected population of Czech divers. Simulated dives indicate that PFO represents a risk factor for paradoxical embolization of gas bubbles. TCD is a suitable screening method for the detection of PFO and the evaluation of R-L shunt significance. These results are indicative of a possible high risk of paradoxical embolization of gas bubbles and the trombogenic substance in patients with a larger PFO and significant R-L shunt undergoing foam sclerotization of varicose veins.
- MeSH
- dekompresní nemoc komplikace MeSH
- echokardiografie MeSH
- foramen ovale apertum komplikace diagnostické zobrazování MeSH
- lidé MeSH
- paradoxní embolie etiologie MeSH
- potápění škodlivé účinky MeSH
- rizikové faktory MeSH
- skleroterapie škodlivé účinky MeSH
- ultrasonografie dopplerovská transkraniální MeSH
- varixy komplikace terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH