-
Je něco špatně v tomto záznamu ?
Characterization of rabbit antibodies for immunochemical detection of Yersinia enterocolitica
I. Hochel, J. Škvor
Jazyk angličtina Země Česko
- MeSH
- chromatografie afinitní metody využití MeSH
- elektroforéza v polyakrylamidovém gelu metody využití MeSH
- ELISA metody využití MeSH
- finanční podpora výzkumu jako téma MeSH
- imunoblotting metody využití MeSH
- imunoglobulin G imunologie izolace a purifikace MeSH
- králíci imunologie MeSH
- sérový albumin hovězí imunologie MeSH
- Yersinia enterocolitica imunologie izolace a purifikace MeSH
- zvířata MeSH
- Check Tag
- králíci imunologie MeSH
- zvířata MeSH
Rabbit IgG raised against whole cells of Yersinia enterocolitica O:3, O:9 and against a group of pathogenic Y. enterocolitica strains (serotypes O:3, O:5,27, O:8. and O:9) were prepared. The antibody limiting titers were within the range of 1:9.5 x 10(4)-1:7.5 x 10(5). The immunoblotting analysis of Yersinia lipopolysacchides separated by SDS-PAGE showed that IgG against the single serotype O:3 interacted with high-molar-mass LPS of O:3 whereas other antibodies were bound to low-molar-mass LPS of serotypes O:3, O:5,27, O:9 and strain Y. enterocolitica (CNCTC Y 2/68). IgG against the group of pathogenic serotypes also weakly interacted with low-molar-mass LPS of serotypes O:5, O:6,30, and O:10. The cross-reactivity of the antibodies with Y. pseudotuberculosis Ia and/or Y. rohdei b, d, e, f, i, which was observed by means of dot-blotting procedure using the whole bacterial cells as an antigen, was shown not to be caused by LPS of these bacteria. The prepared antibodies were used in the development of indirect competitive ELISA. At the optimum concentration of the immunoreactants the detection limits were within the range of 3-7 x 10(6) colony-forming units per mL.
Lit.: 40
- 000
- 03126naa 2200421 a 4500
- 001
- bmc07504130
- 003
- CZ-PrNML
- 005
- 20111210121937.0
- 008
- 080522s2007 xr e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Hochel, Igor, $d 1962- $7 xx0118018
- 245 10
- $a Characterization of rabbit antibodies for immunochemical detection of Yersinia enterocolitica / $c I. Hochel, J. Škvor
- 314 __
- $a Department of Biochemistry and Microbiology, Institute of Chemical Technology, 166 28 Prague, Czechia
- 504 __
- $a Lit.: 40
- 520 9_
- $a Rabbit IgG raised against whole cells of Yersinia enterocolitica O:3, O:9 and against a group of pathogenic Y. enterocolitica strains (serotypes O:3, O:5,27, O:8. and O:9) were prepared. The antibody limiting titers were within the range of 1:9.5 x 10(4)-1:7.5 x 10(5). The immunoblotting analysis of Yersinia lipopolysacchides separated by SDS-PAGE showed that IgG against the single serotype O:3 interacted with high-molar-mass LPS of O:3 whereas other antibodies were bound to low-molar-mass LPS of serotypes O:3, O:5,27, O:9 and strain Y. enterocolitica (CNCTC Y 2/68). IgG against the group of pathogenic serotypes also weakly interacted with low-molar-mass LPS of serotypes O:5, O:6,30, and O:10. The cross-reactivity of the antibodies with Y. pseudotuberculosis Ia and/or Y. rohdei b, d, e, f, i, which was observed by means of dot-blotting procedure using the whole bacterial cells as an antigen, was shown not to be caused by LPS of these bacteria. The prepared antibodies were used in the development of indirect competitive ELISA. At the optimum concentration of the immunoreactants the detection limits were within the range of 3-7 x 10(6) colony-forming units per mL.
- 650 _2
- $a chromatografie afinitní $x metody $x využití $7 D002846
- 650 _2
- $a Yersinia enterocolitica $x imunologie $x izolace a purifikace $7 D015008
- 650 _2
- $a ELISA $x metody $x využití $7 D004797
- 650 _2
- $a elektroforéza v polyakrylamidovém gelu $x metody $x využití $7 D004591
- 650 _2
- $a imunoglobulin G $x imunologie $x izolace a purifikace $7 D007074
- 650 _2
- $a sérový albumin hovězí $x imunologie $7 D012710
- 650 _2
- $a králíci $x imunologie $7 D011817
- 650 _2
- $a imunoblotting $x metody $x využití $7 D015151
- 650 _2
- $a finanční podpora výzkumu jako téma $7 D012109
- 650 _2
- $a zvířata $7 D000818
- 700 1_
- $a Škvor, Jiří
- 773 0_
- $w MED00011005 $t Folia microbiologica $g Roč. 52, č. 5 (2007), s. 511-518 $x 0015-5632
- 856 41
- $u http://www.biomed.cas.cz/mbu/folia/ $y plný text
- 910 __
- $a ABA008 $b A 2403 $c 561 $y 1
- 990 __
- $a 20080522112810 $b ABA008
- 991 __
- $a 20080522153528 $b ABA008
- 999 __
- $a ok $b bmc $g 619752 $s 472185
- BAS __
- $a 3
- BMC __
- $a 2007 $b 52 $c 5 $d 511-518 $i 0015-5632 $m Folia microbiologica $x MED00011005
- LZP __
- $a 2008-3/lmal