Je něco špatně v tomto záznamu ?
Determination of intact heparin by capillary electrophoresis with contactless conductivity detection in background electrolytes containing hydrophilic polymers
Petr Tůma, Eva Samcová, František Opekar, Karel Štulík
Jazyk angličtina Země Česko
NLK
ProQuest Central
od 2005-01-01 do 2011
- MeSH
- elektroforéza kapilární metody MeSH
- elektrolyty MeSH
- financování organizované MeSH
- heparin izolace a purifikace krev MeSH
- lékové roztoky analýza MeSH
- polymery MeSH
- polysacharidy krev MeSH
Intact heparin was characterized and determined in model samples, in infusion solutions and in blood plasma by capillary electrophoresis (CE) with contactless conductivity detection. The CE separation of polydisperse heparin took place in open silica capillaries, in electrolytes containing a polymer (hydroxyethyl)cellulose, poly(ethylene glycol) or dextran. The best separation of heparin from excess inorganic ions present in real samples was attained in a background electrolyte consisting of 0.8 M acetic acid and 1% (w/v) dextran (100 kDa). The limit of detection (LOD) was 1.3 µmol l-1. This electrolyte was used in determination of heparin in blood plasma and in infusion solutions.
Lit.: 35
- 000
- 02490naa 2200409 a 4500
- 001
- bmc07505893
- 003
- CZ-PrNML
- 005
- 20111210122435.0
- 008
- 080630s2008 xr e eng||
- 009
- AR
- 024 7_
- $2 doi $a 10.1135/cccc20080187
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Tůma, Petr $7 xx0105786
- 245 10
- $a Determination of intact heparin by capillary electrophoresis with contactless conductivity detection in background electrolytes containing hydrophilic polymers / $c Petr Tůma, Eva Samcová, František Opekar, Karel Štulík
- 314 __
- $a Institute of Biochemistry, Cell and Molecular Biology, Third Faculty of Medicine, Charles University, Prague 10
- 504 __
- $a Lit.: 35
- 520 9_
- $a Intact heparin was characterized and determined in model samples, in infusion solutions and in blood plasma by capillary electrophoresis (CE) with contactless conductivity detection. The CE separation of polydisperse heparin took place in open silica capillaries, in electrolytes containing a polymer (hydroxyethyl)cellulose, poly(ethylene glycol) or dextran. The best separation of heparin from excess inorganic ions present in real samples was attained in a background electrolyte consisting of 0.8 M acetic acid and 1% (w/v) dextran (100 kDa). The limit of detection (LOD) was 1.3 µmol l-1. This electrolyte was used in determination of heparin in blood plasma and in infusion solutions.
- 650 _2
- $a heparin $x izolace a purifikace $x krev $7 D006493
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a elektrolyty $7 D004573
- 650 _2
- $a polymery $7 D011108
- 650 _2
- $a polysacharidy $x krev $7 D011134
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a lékové roztoky $x analýza $7 D019999
- 700 1_
- $a Samcová, Eva, $d 1947- $7 nlk19990073817
- 700 1_
- $a Opekar, František. $7 _BN004560
- 700 1_
- $a Štulík, Karel, $d 1941-2013 $7 jk01131560
- 773 0_
- $w MED00010973 $t Collection of Czechoslovak chemical communications $g Roč. 73, č. 2 (2008), s. 187-200 $x 0010-0765
- 910 __
- $a ABA008 $b A 1006 $c 394 $y 9
- 990 __
- $a 20080625111328 $b ABA008
- 991 __
- $a 20090223150030 $b ABA008
- 999 __
- $a ok $b bmc $g 621515 $s 473948
- BAS __
- $a 3
- BMC __
- $a 2008 $b 73 $c 2 $d 187-200 $i 0010-0765 $m Collection of Czechoslovak Chemical Communications $x MED00010973
- LZP __
- $a 2008-16/vtmv