Something wrong with this record ?
New clearance evaluation method for hepatological diagnostics
Josef A. Tichý, Miloslav Loučka, Zdeněk M. Trefný, Markéta Hojerová, Jiří Svačinka, Jindřich Müller, Michaela Friedrichová
Language English Country Czech Republic
NLK
Directory of Open Access Journals
from 1991
Free Medical Journals
from 1998
ProQuest Central
from 2005-01-01
Medline Complete (EBSCOhost)
from 2006-01-01
Nursing & Allied Health Database (ProQuest)
from 2005-01-01
Health & Medicine (ProQuest)
from 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
from 1998
- MeSH
- Coloring Agents diagnostic use pharmacokinetics MeSH
- Models, Biological MeSH
- Densitometry methods standards MeSH
- Adult MeSH
- Financing, Organized MeSH
- Indocyanine Green diagnostic use pharmacokinetics MeSH
- Liver Function Tests methods mortality MeSH
- Body Fluid Compartments MeSH
- Middle Aged MeSH
- Humans MeSH
- Cardiac Output MeSH
- Young Adult MeSH
- Nonlinear Dynamics MeSH
- Regression Analysis MeSH
- Aged MeSH
- Fatty Liver diagnosis metabolism MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Young Adult MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
Pulse dye densitometry (PDD) enables the evaluation of hemodynamic state as well as liver function. A repeated examination, even after a short pause (or under stress condition), enables to follow safely the dynamics of liver pathology. From presented parameters we have evaluated as reliable the C5-clearance, an expression of equilibrium state in the two compartment liver system. Furthermore, T-index expresses ratio of C5 value to cardiac output, it is a sensitive indicator of the blood pole, i.e. sinusoidal uptake, which is in very good correlation with staging of hepatopathies. The isolated h constant in correlation to T-index is valuable For functional grading. The Japanese automatic analyzer of indocyanine green (ICG) dilution and elimination curves, after incorporation of a two compartment mathematical model, becomes more useful for complex hepatological diagnostics. Non-invasive PDD is becoming of uppermost importance to clinical interest, yielding comparable results as other complicated and invasive examinations and may be, therefore, repeated in short time intervals for different indications with minimal stress of examined patient.
References provided by Crossref.org
Lit.: 22
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07530786
- 003
- CZ-PrNML
- 005
- 20111210151809.0
- 008
- 091012s2009 xr e eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.931254 $2 doi
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Tichý, Josef A., $d 1929-2018 $7 js20051031042
- 245 10
- $a New clearance evaluation method for hepatological diagnostics / $c Josef A. Tichý, Miloslav Loučka, Zdeněk M. Trefný, Markéta Hojerová, Jiří Svačinka, Jindřich Müller, Michaela Friedrichová
- 314 __
- $a Institute of Chemical Technology, Department of Mathematics, Prague
- 504 __
- $a Lit.: 22
- 520 9_
- $a Pulse dye densitometry (PDD) enables the evaluation of hemodynamic state as well as liver function. A repeated examination, even after a short pause (or under stress condition), enables to follow safely the dynamics of liver pathology. From presented parameters we have evaluated as reliable the C5-clearance, an expression of equilibrium state in the two compartment liver system. Furthermore, T-index expresses ratio of C5 value to cardiac output, it is a sensitive indicator of the blood pole, i.e. sinusoidal uptake, which is in very good correlation with staging of hepatopathies. The isolated h constant in correlation to T-index is valuable For functional grading. The Japanese automatic analyzer of indocyanine green (ICG) dilution and elimination curves, after incorporation of a two compartment mathematical model, becomes more useful for complex hepatological diagnostics. Non-invasive PDD is becoming of uppermost importance to clinical interest, yielding comparable results as other complicated and invasive examinations and may be, therefore, repeated in short time intervals for different indications with minimal stress of examined patient.
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a kompartmenty tělních tekutin $7 D001825
- 650 _2
- $a minutový srdeční výdej $7 D002302
- 650 _2
- $a barvicí látky $x diagnostické užití $x farmakokinetika $7 D004396
- 650 _2
- $a denzitometrie $x metody $x normy $7 D003720
- 650 _2
- $a ztučnělá játra $x diagnóza $x metabolismus $7 D005234
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a indokyanová zeleň $x diagnostické užití $x farmakokinetika $7 D007208
- 650 _2
- $a jaterní testy $x metody $x mortalita $7 D008111
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a biologické modely $7 D008954
- 650 _2
- $a nelineární dynamika $7 D017711
- 650 _2
- $a regresní analýza $7 D012044
- 650 _2
- $a mladý dospělý $7 D055815
- 700 1_
- $a Loučka, Miloslav $7 xx0078784
- 700 1_
- $a Trefný, Zdeněk M., $d 1920- $7 nlk20020104994
- 700 1_
- $a Hojerová, Markéta $7 xx0074135
- 700 1_
- $a Svačinka, Jiří $7 xx0144869
- 700 1_
- $a Müller, Jindřich $7 xx0092192
- 700 0_
- $a Friedrichová, Michaela $7 xx0105589
- 773 0_
- $w MED00003824 $t Physiological research $g Roč. 58, č. 2 (2009), s. 287-292 $x 0862-8408
- 856 41
- $u http://www.biomed.cas.cz/physiolres/pdf/58/58_287.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 9
- 990 __
- $a 20091009100046 $b ABA008
- 991 __
- $a 20091012101136 $b ABA008
- 999 __
- $a ok $b bmc $g 689312 $s 551154
- BAS __
- $a 3
- BMC __
- $a 2009 $b 58 $c 2 $d 287-292 $i 0862-8408 $m Physiological research $x MED00003824
- LZP __
- $a 2009-32/mkme