• Something wrong with this record ?

New clearance evaluation method for hepatological diagnostics

Josef A. Tichý, Miloslav Loučka, Zdeněk M. Trefný, Markéta Hojerová, Jiří Svačinka, Jindřich Müller, Michaela Friedrichová

. 2009 ; 58 (2) : 287-292.

Language English Country Czech Republic

Pulse dye densitometry (PDD) enables the evaluation of hemodynamic state as well as liver function. A repeated examination, even after a short pause (or under stress condition), enables to follow safely the dynamics of liver pathology. From presented parameters we have evaluated as reliable the C5-clearance, an expression of equilibrium state in the two compartment liver system. Furthermore, T-index expresses ratio of C5 value to cardiac output, it is a sensitive indicator of the blood pole, i.e. sinusoidal uptake, which is in very good correlation with staging of hepatopathies. The isolated h constant in correlation to T-index is valuable For functional grading. The Japanese automatic analyzer of indocyanine green (ICG) dilution and elimination curves, after incorporation of a two compartment mathematical model, becomes more useful for complex hepatological diagnostics. Non-invasive PDD is becoming of uppermost importance to clinical interest, yielding comparable results as other complicated and invasive examinations and may be, therefore, repeated in short time intervals for different indications with minimal stress of examined patient.

References provided by Crossref.org

Bibliography, etc.

Lit.: 22

000      
00000naa 2200000 a 4500
001      
bmc07530786
003      
CZ-PrNML
005      
20111210151809.0
008      
091012s2009 xr e eng||
009      
AR
024    7_
$a 10.33549/physiolres.931254 $2 doi
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Tichý, Josef A., $d 1929-2018 $7 js20051031042
245    10
$a New clearance evaluation method for hepatological diagnostics / $c Josef A. Tichý, Miloslav Loučka, Zdeněk M. Trefný, Markéta Hojerová, Jiří Svačinka, Jindřich Müller, Michaela Friedrichová
314    __
$a Institute of Chemical Technology, Department of Mathematics, Prague
504    __
$a Lit.: 22
520    9_
$a Pulse dye densitometry (PDD) enables the evaluation of hemodynamic state as well as liver function. A repeated examination, even after a short pause (or under stress condition), enables to follow safely the dynamics of liver pathology. From presented parameters we have evaluated as reliable the C5-clearance, an expression of equilibrium state in the two compartment liver system. Furthermore, T-index expresses ratio of C5 value to cardiac output, it is a sensitive indicator of the blood pole, i.e. sinusoidal uptake, which is in very good correlation with staging of hepatopathies. The isolated h constant in correlation to T-index is valuable For functional grading. The Japanese automatic analyzer of indocyanine green (ICG) dilution and elimination curves, after incorporation of a two compartment mathematical model, becomes more useful for complex hepatological diagnostics. Non-invasive PDD is becoming of uppermost importance to clinical interest, yielding comparable results as other complicated and invasive examinations and may be, therefore, repeated in short time intervals for different indications with minimal stress of examined patient.
650    _2
$a financování organizované $7 D005381
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a kompartmenty tělních tekutin $7 D001825
650    _2
$a minutový srdeční výdej $7 D002302
650    _2
$a barvicí látky $x diagnostické užití $x farmakokinetika $7 D004396
650    _2
$a denzitometrie $x metody $x normy $7 D003720
650    _2
$a ztučnělá játra $x diagnóza $x metabolismus $7 D005234
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a indokyanová zeleň $x diagnostické užití $x farmakokinetika $7 D007208
650    _2
$a jaterní testy $x metody $x mortalita $7 D008111
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a biologické modely $7 D008954
650    _2
$a nelineární dynamika $7 D017711
650    _2
$a regresní analýza $7 D012044
650    _2
$a mladý dospělý $7 D055815
700    1_
$a Loučka, Miloslav $7 xx0078784
700    1_
$a Trefný, Zdeněk M., $d 1920- $7 nlk20020104994
700    1_
$a Hojerová, Markéta $7 xx0074135
700    1_
$a Svačinka, Jiří $7 xx0144869
700    1_
$a Müller, Jindřich $7 xx0092192
700    0_
$a Friedrichová, Michaela $7 xx0105589
773    0_
$w MED00003824 $t Physiological research $g Roč. 58, č. 2 (2009), s. 287-292 $x 0862-8408
856    41
$u http://www.biomed.cas.cz/physiolres/pdf/58/58_287.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 4120 $c 266 $y 9
990    __
$a 20091009100046 $b ABA008
991    __
$a 20091012101136 $b ABA008
999    __
$a ok $b bmc $g 689312 $s 551154
BAS    __
$a 3
BMC    __
$a 2009 $b 58 $c 2 $d 287-292 $i 0862-8408 $m Physiological research $x MED00003824
LZP    __
$a 2009-32/mkme

Find record

Citation metrics

Loading data ...

Archiving options