• Je něco špatně v tomto záznamu ?

Human motion analysis and its application in sports and sport medicine

Zlatica Dolná, Dušan Šimšík, Jaroslav Majerník, Alena Galajdová

. 2008 ; 38 (2) : 152-155.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc07531379

The paper presents an overview of the systems used for human motion analysis and a brief description of their application. We use optical motion capture system SMART from e-Motion, BTS based on detection of small passive refl ex markers, to analyze subjects' movements in our studies. Th e aim is to estimate and assess movement, abilities in pathological cases evaluated in clinical fi eld, e.g. rehabilitation, gait analysis utilisation, stability disorders and also in sports medicine. Th e application of the system SMART is set to laboratory conditions for recording exercises, monitoring of performance, evaluation of motion abilities, development of individual skills, training of correct and/or optimal trajectories and to ensure the feedback. Th is exact approach is more precise than commonly applied methods based on subjective visual analysis and brings objectivization and quantifi cation of human motion that is very signifi cant also in sports and sport medicine.

The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic

Bibliografie atd.

Lit.: 19

000      
00000naa 2200000 a 4500
001      
bmc07531379
003      
CZ-PrNML
005      
20240528102844.0
008      
091019s2008 xr e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Dolná, Zlatica $7 xx0317515
245    10
$a Human motion analysis and its application in sports and sport medicine / $c Zlatica Dolná, Dušan Šimšík, Jaroslav Majerník, Alena Galajdová
314    __
$a Technical University of Košice, Faculty of Mechanical Engineering, Department of Biomedical Engineering, Automation and Measurement, Košice
500    __
$a The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
504    __
$a Lit.: 19
520    9_
$a The paper presents an overview of the systems used for human motion analysis and a brief description of their application. We use optical motion capture system SMART from e-Motion, BTS based on detection of small passive refl ex markers, to analyze subjects' movements in our studies. Th e aim is to estimate and assess movement, abilities in pathological cases evaluated in clinical fi eld, e.g. rehabilitation, gait analysis utilisation, stability disorders and also in sports medicine. Th e application of the system SMART is set to laboratory conditions for recording exercises, monitoring of performance, evaluation of motion abilities, development of individual skills, training of correct and/or optimal trajectories and to ensure the feedback. Th is exact approach is more precise than commonly applied methods based on subjective visual analysis and brings objectivization and quantifi cation of human motion that is very signifi cant also in sports and sport medicine.
650    _2
$a pohyb $x fyziologie $7 D009068
650    _2
$a sporty $x fyziologie $7 D013177
650    _2
$a tělovýchovné lékařství $x metody $x přístrojové vybavení $x trendy $7 D013178
650    _2
$a pohybová aktivita $x fyziologie $7 D009043
650    _2
$a audiovizuální záznam $x metody $x přístrojové vybavení $x využití $7 D014741
650    _2
$a elektromyografie $x metody $x přístrojové vybavení $x využití $7 D004576
650    _2
$a experimenty na lidech $7 D006805
650    _2
$a lehká atletika $x fyziologie $7 D014142
650    _2
$a postura těla $x fyziologie $7 D011187
650    _2
$a monitorování fyziologických funkcí $x metody $x přístrojové vybavení $x využití $7 D008991
650    _2
$a automatizované zpracování dat $x metody $x přístrojové vybavení $x využití $7 D001330
650    _2
$a financování organizované $7 D005381
650    _2
$a lidé $7 D006801
700    1_
$a Šimšík, Dušan, $d 1950- $7 jx20050617048
700    1_
$a Majerník, Jaroslav $7 xx0103257
700    1_
$a Galajdová, Alena $7 xx0126568
773    0_
$w MED00011033 $t Lékař a technika $g Roč. 38, č. 2 (2008), s. 152-155 $x 0301-5491
856    41
$u http://www.sbmili.cz/journal/LaT_2008_2.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 1367 $c 1071 b $y 9 $z 0
990    __
$a 20091016134404 $b ABA008
991    __
$a 20240528102841 $b ABA008
999    __
$a ok $b bmc $g 690232 $s 552118
BAS    __
$a 3
BMC    __
$a 2008 $b 38 $c 2 $d 152-155 $i 0301-5491 $m Lékař a technika $x MED00011033
LZP    __
$a 2009-54/vtal

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...