-
Je něco špatně v tomto záznamu ?
The measurement and evaluation of basic ventilation modes and failure simulations on ventilation circuit
Vavřík David, Hájek Michal, Penhaker Marek
Jazyk angličtina Země Česko
- MeSH
- lidé MeSH
- mechanické ventilátory využití MeSH
- monitorování fyziologických funkcí metody přístrojové vybavení využití MeSH
- plicní ventilace fyziologie MeSH
- počítačová simulace využití MeSH
- počítačové zpracování signálu přístrojové vybavení MeSH
- software trendy MeSH
- Check Tag
- lidé MeSH
The subject of this project was the design and realization of laboratory measuring exercise on the mechanical ventilator. Pneumatic mechanical ventilator MARK8 from Bird Corporation Company was chosen. It is usable for three basic ventilation modes. Th ere are spontaneous, assist and controlled ventilation. We use Lilly type pneumotachometer for ventilation circuit evaluation from Hamilton company. It is usable for calm breathing. Diff erential pressure sensor Omega TX278-05D5V for diff erence pressure evaluation is being used. Also A/D card NI USB-9215 from National Instruments company as convertor to PC is being used. Measuring data are displayed in LabView. Th e Subject of Laboratory exercise is setting and measuring basic ventilation modes and failures simulation on the ventilation circuit.
The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07531447
- 003
- CZ-PrNML
- 005
- 20111210152053.0
- 008
- 091020s2008 xr e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Vavřík, David. $7 _AN038889
- 245 14
- $a The measurement and evaluation of basic ventilation modes and failure simulations on ventilation circuit / $c Vavřík David, Hájek Michal, Penhaker Marek
- 314 __
- $a VŠB – Technical University of Ostrava, Faculty of Electrical Engineering and Computer Science, Ostrava
- 500 __
- $a The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
- 520 9_
- $a The subject of this project was the design and realization of laboratory measuring exercise on the mechanical ventilator. Pneumatic mechanical ventilator MARK8 from Bird Corporation Company was chosen. It is usable for three basic ventilation modes. Th ere are spontaneous, assist and controlled ventilation. We use Lilly type pneumotachometer for ventilation circuit evaluation from Hamilton company. It is usable for calm breathing. Diff erential pressure sensor Omega TX278-05D5V for diff erence pressure evaluation is being used. Also A/D card NI USB-9215 from National Instruments company as convertor to PC is being used. Measuring data are displayed in LabView. Th e Subject of Laboratory exercise is setting and measuring basic ventilation modes and failures simulation on the ventilation circuit.
- 650 _2
- $a plicní ventilace $x fyziologie $7 D012123
- 650 _2
- $a mechanické ventilátory $x využití $7 D012122
- 650 _2
- $a monitorování fyziologických funkcí $x metody $x přístrojové vybavení $x využití $7 D008991
- 650 _2
- $a počítačové zpracování signálu $x přístrojové vybavení $7 D012815
- 650 _2
- $a počítačová simulace $x využití $7 D003198
- 650 _2
- $a software $x trendy $7 D012984
- 650 _2
- $a lidé $7 D006801
- 700 1_
- $a Hájek, Michal $7 xx0089812
- 700 1_
- $a Penhaker, Marek, $d 1972- $7 mzk2004246505
- 773 0_
- $w MED00011033 $t Lékař a technika $g Roč. 38, č. 2 (2008), s. 191-194 $x 0301-5491
- 856 41
- $u http://www.sbmili.cz/journal/LaT_2008_2.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y 9
- 990 __
- $a 20091016134404 $b ABA008
- 991 __
- $a 20091020164436 $b ABA008
- 999 __
- $a ok $b bmc $g 690303 $s 552189
- BAS __
- $a 3
- BMC __
- $a 2008 $b 38 $c 2 $d 191-194 $i 0301-5491 $m Lékař a technika $x MED00011033
- LZP __
- $a 2009-54/vtal