• Something wrong with this record ?

Stanovení tloušťky obalu tablet blízkou infračervenou spektroskopií
[Determination of the thickness of tablet coating by near-infrared spectroscopy]

Jan Muselík, Kateřina Krejčová, Miloslava Rabišková, Anna Bartošíková, Michaela Dračková, Lenka Vorlová

. 2010 ; 104 (1) : 41-45.

Language Czech Country Czech Republic

The aim of this study was to develop a fast and reliable method for determination of tablet coating thickness. Tablets were coated with polymeric Pharmacoat® 606 in a laboratory coater. The coating thickness was measured by near-IR absorption of the coating material using calibration. The calibration and validation results afforded the following parameters: determination coefficient R2 > 0.97, the number of factors 6 and the standard error of crossvalidation 5.4 ?m at the coating thickness 25–125 ?m. The obtained results confirmed suitability of the method for evaluation of coating quality.

Determination of the thickness of tablet coating by near-infrared spectroscopy

Bibliography, etc.

Lit.: 17

000      
00000naa 2200000 a 4500
001      
bmc10008217
003      
CZ-PrNML
005      
20111210162014.0
008      
100409s2010 xr e cze||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Muselík, Jan $7 xx0100243
245    10
$a Stanovení tloušťky obalu tablet blízkou infračervenou spektroskopií / $c Jan Muselík, Kateřina Krejčová, Miloslava Rabišková, Anna Bartošíková, Michaela Dračková, Lenka Vorlová
246    11
$a Determination of the thickness of tablet coating by near-infrared spectroscopy
314    __
$a Ústav technologie léků, Farmaceutická fakulta, Veterinární a farmaceutická univerzita, Brno
504    __
$a Lit.: 17
520    9_
$a The aim of this study was to develop a fast and reliable method for determination of tablet coating thickness. Tablets were coated with polymeric Pharmacoat® 606 in a laboratory coater. The coating thickness was measured by near-IR absorption of the coating material using calibration. The calibration and validation results afforded the following parameters: determination coefficient R2 > 0.97, the number of factors 6 and the standard error of crossvalidation 5.4 ?m at the coating thickness 25–125 ?m. The obtained results confirmed suitability of the method for evaluation of coating quality.
650    _2
$a lékové formy $7 D004304
650    _2
$a enterosolventní tablety $7 D013608
650    _2
$a farmaceutická technologie $7 D013678
650    _2
$a farmaceutické pomocné látky $x analýza $7 D010592
650    _2
$a methylcelulosa $x analogy a deriváty $x analýza $7 D008747
650    _2
$a blízká infračervená spektroskopie $x využití $7 D019265
700    1_
$a Krejčová, Kateřina. $7 _BN000721
700    1_
$a Rabišková, Miloslava, $d 1951- $7 mzk2005290121
700    1_
$a Bartošíková, A. $7 _AN041487
700    1_
$a Dračková, Michaela. $7 xx0036971
700    1_
$a Vorlová, Lenka $7 ola2004212066
773    0_
$w MED00011010 $t Chemické listy $g Roč. 104, č. 1 (2010), s. 41-45 $x 0009-2770
856    41
$u http://www.chemicke-listy.cz/docs/full/2010_01_41-45.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y 8
990    __
$a 20100408105345 $b ABA008
991    __
$a 20100409065520 $b ABA008
999    __
$a ok $b bmc $g 722112 $s 585200
BAS    __
$a 3
BMC    __
$a 2010 $b 104 $c 1 $d 41-45 $i 0009-2770 $m Chemické listy $x MED00011010
LZP    __
$a 2010-18/ipmv

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...