• Something wrong with this record ?

Suitable conditions for sealing of open dentinal tubules using a pulsed Nd:YAG laser

Z Zapletalova, J Jr Perina, R Novotny, H Chmelickova

. 2007 ; 25 (6) : 495-499.

Language English Country United States

Document type Comparative Study

BACKGROUND DATA AND OBJECTIVES: Nd:YAG laser radiation has been applied in treatment of dentine hypersensitivity; dentine melt created after irradiation on a tooth surface can occlude open dentinal tubules. Different conditions (energy of pulses, number of successive irradiations, and type of dye agent) have been reported in the literature. In our study, different conditions are compared and the most suitable ones are suggested. METHODS: One hundred nine dentine samples prepared from extracted human third molars in the form of 2- or 3-mm thick discs and facets from an outer convex surface of a root were irradiated by pulses with duration 0.3 ms and beam diameter 0.3 or 0.6 mm. The laser repetition rate was 15 Hz. Energies per pulse have been changed from 20 mJ to 250 mJ (the corresponding energy densities rho are 22 and 275 J/cm(2) for the beam diameter of 0.3 mm). Dyes including tartrazine, carmine indigo, erythrosin, and methylene blue have been used to cover dentine surfaces and to increase absorption of laser radiation. Irradiated dentine surfaces have been investigated using scanning electron microscopy. RESULTS: Sealing of open dentinal tubules can be accomplished even without dyes, provided that a sufficiently intense laser radiation level is used. To avoid damage to the dentine's surface the use of dyes is necessary. Erythrosin has been found to be the best agent, and closing of dentinal tubules occurred after four doses of irradiation with 30-mJ pulses with a beam diameter of 0.6 mm (energy density rho = 8.25 J/cm(2), total energy density rho(T) = 33 J/cm(2)). The upper limit has been reached using four doses of irradiation by 90-mJ pulses with a beam diameter of 0.3 mm (rho = 99 J/cm(2), rho(T) = 396 J/cm(2)). CONCLUSIONS: Occluding dentinal tubules can safely and effectively be accomplished using pulsed Nd:YAG laser radiation provided that the dentine surface is covered with erythrosin solution.

000      
00000naa 2200000 a 4500
001      
bmc10026542
003      
CZ-PrNML
005      
20120126170521.0
008      
101019s2007 xxu e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Zapletalová, Zdeňka $7 xx0042713
245    10
$a Suitable conditions for sealing of open dentinal tubules using a pulsed Nd:YAG laser / $c Z Zapletalova, J Jr Perina, R Novotny, H Chmelickova
314    __
$a Clinic of Dentistry, Faculty of Medicine, Palacky University, Czech Republic. zdenazap@tunw.upol.cz
520    9_
$a BACKGROUND DATA AND OBJECTIVES: Nd:YAG laser radiation has been applied in treatment of dentine hypersensitivity; dentine melt created after irradiation on a tooth surface can occlude open dentinal tubules. Different conditions (energy of pulses, number of successive irradiations, and type of dye agent) have been reported in the literature. In our study, different conditions are compared and the most suitable ones are suggested. METHODS: One hundred nine dentine samples prepared from extracted human third molars in the form of 2- or 3-mm thick discs and facets from an outer convex surface of a root were irradiated by pulses with duration 0.3 ms and beam diameter 0.3 or 0.6 mm. The laser repetition rate was 15 Hz. Energies per pulse have been changed from 20 mJ to 250 mJ (the corresponding energy densities rho are 22 and 275 J/cm(2) for the beam diameter of 0.3 mm). Dyes including tartrazine, carmine indigo, erythrosin, and methylene blue have been used to cover dentine surfaces and to increase absorption of laser radiation. Irradiated dentine surfaces have been investigated using scanning electron microscopy. RESULTS: Sealing of open dentinal tubules can be accomplished even without dyes, provided that a sufficiently intense laser radiation level is used. To avoid damage to the dentine's surface the use of dyes is necessary. Erythrosin has been found to be the best agent, and closing of dentinal tubules occurred after four doses of irradiation with 30-mJ pulses with a beam diameter of 0.6 mm (energy density rho = 8.25 J/cm(2), total energy density rho(T) = 33 J/cm(2)). The upper limit has been reached using four doses of irradiation by 90-mJ pulses with a beam diameter of 0.3 mm (rho = 99 J/cm(2), rho(T) = 396 J/cm(2)). CONCLUSIONS: Occluding dentinal tubules can safely and effectively be accomplished using pulsed Nd:YAG laser radiation provided that the dentine surface is covered with erythrosin solution.
650    _2
$a dentin $x účinky záření $x ultrastruktura $7 D003804
650    _2
$a permeabilita dentinu $x účinky záření $7 D003806
650    _2
$a citlivost dentinu $x prevence a kontrola $7 D003807
650    _2
$a erythrosin $x aplikace a dávkování $x terapeutické užití $7 D004923
650    _2
$a fluorescenční barviva $x aplikace a dávkování $x terapeutické užití $7 D005456
650    _2
$a lidé $7 D006801
650    _2
$a laserová terapie $7 D053685
650    _2
$a mikroskopie elektronová rastrovací $7 D008855
650    _2
$a neodym $7 D009354
650    _2
$a financování organizované $7 D005381
650    _2
$a techniky in vitro $7 D066298
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Peřina, Jan, $d 1969- $7 xx0061154
700    1_
$a Novotný, Radko $7 xx0061155
700    1_
$a Chmelíčková, Hana $7 xx0061158
773    0_
$t Photomedicine and Laser Surgery $w MED00181053 $g Roč. 25, č. 6 (2007), s. 495-499 $x 1549-5418
910    __
$a ABA008 $b x $y 7
990    __
$a 20110228122131 $b ABA008
991    __
$a 20120126170507 $b ABA008
999    __
$a ok $b bmc $g 801648 $s 666399
BAS    __
$a 3
BMC    __
$a 2007 $b 25 $c 6 $d 495-499 $i 1549-5418 $m Photomedicine and laser surgery $n Photomed Laser Surg $x MED00181053
LZP    __
$a 2010-B/mk

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...