• Something wrong with this record ?

Comparative study of non-invasive blood pressure measurement methods in elderly people

V Fabian, M Janouch, L Novakova, O Stepankova

Language English Country United States

Document type Comparative Study

Results obtained by the modern automatic blood pressure (BP) monitors using oscillometric method [5] are highly dependent on conditions of cardiovascular system of the monitored person. Especially, with people who suffer from cardiovascular diseases (e.g. atherosclerosis) the resulting values differ significantly from those measured by the traditional auscultation method. A reasonable solution for improvement of quality of oscillometric method could be a sophisticated intelligent BP measuring system which applies for evaluation of BP more complex approach taking into account the monitored person's condition of patient cardiovascular system (CS) i.e. the hemodynamic parameters of CS (e.g. heart rate, stroke volume, total peripheral resistance, systemic arterial compliance, pulse wave velocity, augmentation index etc.). Such a system has to be based on appropriate models of the considered diseases which are validated on real life data. For that purpose, we have started to build a database of real-life oscillometric pulsations waveforms (OPW) complemented by the values of "auscultation" blood pressure measurements and additional relevant information about the considered patients (age, sex, etc.) as well as their diagnosis. This data collection requires a special HW device for measurement of the OPW--we have developed such a device and it has been validated in Czech Certified Metrological Centre. Our OPW monitor is connected through the T-pieces and tubes to the cuff, mercury sphygmomanometer and automatic "oscillometric" blood pressure monitor.

000      
00000naa 2200000 a 4500
001      
bmc10026785
003      
CZ-PrNML
005      
20111210192453.0
008      
101019s2007 xxu e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Fabián, Vratislav $7 xx0087412
245    10
$a Comparative study of non-invasive blood pressure measurement methods in elderly people / $c V Fabian, M Janouch, L Novakova, O Stepankova
314    __
$a Czech Technical University in Prague, Faculty of Electrical Engineering, Department of Cybernetics, Technicka 2, Prague 6, Czech Republic. fabiav1@fel.cvut.cz
520    9_
$a Results obtained by the modern automatic blood pressure (BP) monitors using oscillometric method [5] are highly dependent on conditions of cardiovascular system of the monitored person. Especially, with people who suffer from cardiovascular diseases (e.g. atherosclerosis) the resulting values differ significantly from those measured by the traditional auscultation method. A reasonable solution for improvement of quality of oscillometric method could be a sophisticated intelligent BP measuring system which applies for evaluation of BP more complex approach taking into account the monitored person's condition of patient cardiovascular system (CS) i.e. the hemodynamic parameters of CS (e.g. heart rate, stroke volume, total peripheral resistance, systemic arterial compliance, pulse wave velocity, augmentation index etc.). Such a system has to be based on appropriate models of the considered diseases which are validated on real life data. For that purpose, we have started to build a database of real-life oscillometric pulsations waveforms (OPW) complemented by the values of "auscultation" blood pressure measurements and additional relevant information about the considered patients (age, sex, etc.) as well as their diagnosis. This data collection requires a special HW device for measurement of the OPW--we have developed such a device and it has been validated in Czech Certified Metrological Centre. Our OPW monitor is connected through the T-pieces and tubes to the cuff, mercury sphygmomanometer and automatic "oscillometric" blood pressure monitor.
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a ambulantní monitorování krevního tlaku $x metody $x přístrojové vybavení $7 D018660
650    _2
$a monitory krevního tlaku $7 D015924
650    _2
$a kardiovaskulární nemoci $x patofyziologie $7 D002318
650    _2
$a databáze faktografické $7 D016208
650    _2
$a triáda sportovkyň $7 D053716
650    _2
$a hemodynamika $7 D006439
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a financování organizované $7 D005381
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Janouch, Martin $7 xx0087413
700    1_
$a Nováková, Lenka, $d 1978- $7 ntka173590
700    1_
$a Štěpánková, Olga, $d 1949- $7 mzk2004219448
773    0_
$t Conf Proc IEEE Eng Med Biol Soc. $w MED00180111 $g (2007), s. 612-615 $x 1557-170X
910    __
$a ABA008 $b x $y 7
990    __
$a 20110413105426 $b ABA008
991    __
$a 20110413105426 $b ABA008
999    __
$a ok $b bmc $g 801890 $s 666650
BAS    __
$a 3
BMC    __
$a 2007 $d 612-615 $i 1557-170X $m Conference proceedings ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society $n Conf Proc IEEE Eng Med Biol Soc $x MED00180111
LZP    __
$a 2010-B3/vtme

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...