Comparative study of non-invasive blood pressure measurement methods in elderly people
V Fabian, M Janouch, L Novakova, O Stepankova
Language English Country United States
Document type Comparative Study
- MeSH
- Blood Pressure Monitoring, Ambulatory methods instrumentation MeSH
- Databases, Factual MeSH
- Financing, Organized MeSH
- Hemodynamics MeSH
- Cardiovascular Diseases physiopathology MeSH
- Middle Aged MeSH
- Humans MeSH
- Blood Pressure Monitors MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female Athlete Triad Syndrome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Publication type
- Comparative Study MeSH
Results obtained by the modern automatic blood pressure (BP) monitors using oscillometric method [5] are highly dependent on conditions of cardiovascular system of the monitored person. Especially, with people who suffer from cardiovascular diseases (e.g. atherosclerosis) the resulting values differ significantly from those measured by the traditional auscultation method. A reasonable solution for improvement of quality of oscillometric method could be a sophisticated intelligent BP measuring system which applies for evaluation of BP more complex approach taking into account the monitored person's condition of patient cardiovascular system (CS) i.e. the hemodynamic parameters of CS (e.g. heart rate, stroke volume, total peripheral resistance, systemic arterial compliance, pulse wave velocity, augmentation index etc.). Such a system has to be based on appropriate models of the considered diseases which are validated on real life data. For that purpose, we have started to build a database of real-life oscillometric pulsations waveforms (OPW) complemented by the values of "auscultation" blood pressure measurements and additional relevant information about the considered patients (age, sex, etc.) as well as their diagnosis. This data collection requires a special HW device for measurement of the OPW--we have developed such a device and it has been validated in Czech Certified Metrological Centre. Our OPW monitor is connected through the T-pieces and tubes to the cuff, mercury sphygmomanometer and automatic "oscillometric" blood pressure monitor.
- 000
- 00000naa 2200000 a 4500
- 001
- bmc10026785
- 003
- CZ-PrNML
- 005
- 20111210192453.0
- 008
- 101019s2007 xxu e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Fabián, Vratislav $7 xx0087412
- 245 10
- $a Comparative study of non-invasive blood pressure measurement methods in elderly people / $c V Fabian, M Janouch, L Novakova, O Stepankova
- 314 __
- $a Czech Technical University in Prague, Faculty of Electrical Engineering, Department of Cybernetics, Technicka 2, Prague 6, Czech Republic. fabiav1@fel.cvut.cz
- 520 9_
- $a Results obtained by the modern automatic blood pressure (BP) monitors using oscillometric method [5] are highly dependent on conditions of cardiovascular system of the monitored person. Especially, with people who suffer from cardiovascular diseases (e.g. atherosclerosis) the resulting values differ significantly from those measured by the traditional auscultation method. A reasonable solution for improvement of quality of oscillometric method could be a sophisticated intelligent BP measuring system which applies for evaluation of BP more complex approach taking into account the monitored person's condition of patient cardiovascular system (CS) i.e. the hemodynamic parameters of CS (e.g. heart rate, stroke volume, total peripheral resistance, systemic arterial compliance, pulse wave velocity, augmentation index etc.). Such a system has to be based on appropriate models of the considered diseases which are validated on real life data. For that purpose, we have started to build a database of real-life oscillometric pulsations waveforms (OPW) complemented by the values of "auscultation" blood pressure measurements and additional relevant information about the considered patients (age, sex, etc.) as well as their diagnosis. This data collection requires a special HW device for measurement of the OPW--we have developed such a device and it has been validated in Czech Certified Metrological Centre. Our OPW monitor is connected through the T-pieces and tubes to the cuff, mercury sphygmomanometer and automatic "oscillometric" blood pressure monitor.
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a ambulantní monitorování krevního tlaku $x metody $x přístrojové vybavení $7 D018660
- 650 _2
- $a monitory krevního tlaku $7 D015924
- 650 _2
- $a kardiovaskulární nemoci $x patofyziologie $7 D002318
- 650 _2
- $a databáze faktografické $7 D016208
- 650 _2
- $a triáda sportovkyň $7 D053716
- 650 _2
- $a hemodynamika $7 D006439
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a financování organizované $7 D005381
- 655 _2
- $a srovnávací studie $7 D003160
- 700 1_
- $a Janouch, Martin $7 xx0087413
- 700 1_
- $a Nováková, Lenka, $d 1978- $7 ntka173590
- 700 1_
- $a Štěpánková, Olga, $d 1949- $7 mzk2004219448
- 773 0_
- $t Conf Proc IEEE Eng Med Biol Soc. $w MED00180111 $g (2007), s. 612-615 $x 1557-170X
- 910 __
- $a ABA008 $b x $y 7
- 990 __
- $a 20110413105426 $b ABA008
- 991 __
- $a 20110413105426 $b ABA008
- 999 __
- $a ok $b bmc $g 801890 $s 666650
- BAS __
- $a 3
- BMC __
- $a 2007 $d 612-615 $i 1557-170X $m Conference proceedings ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society $n Conf Proc IEEE Eng Med Biol Soc $x MED00180111
- LZP __
- $a 2010-B3/vtme