Srovnávání dvou metod měření termického prahu bolesti na ocasu laboratorního potkana
[Comparison of two methods of tail flick latency measurement in rat]
Tomáš Beran, Šimon Vaculín, Miloslav Franěk
Jazyk čeština Země Česko
Typ dokumentu srovnávací studie
- Klíčová slova
- tail flick test, modifikovaný tail flick test, plantar test, potkan,
- MeSH
- analgezie metody využití MeSH
- baklofen aplikace a dávkování MeSH
- financování organizované MeSH
- hyperalgezie chemicky indukované MeSH
- kapsaicin aplikace a dávkování metabolismus MeSH
- měření bolesti metody veterinární MeSH
- nocicepce MeSH
- potkani Wistar MeSH
- práh bolesti klasifikace účinky léků MeSH
- zvířata MeSH
- Check Tag
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- srovnávací studie MeSH
Intensive thermal stimulation of various skin areas is one of the most common behavioral pain-measurement methods used either in humans or in experimental animals. In tail-flick test, the thermal stimulation is focused on the dorsal surface of the tail in restrained animal, while in the plantar test, the stimulation is focused on the foot planta through a glass table in freely moving rats. We modified the tail-flick test in the way that the tail withdrawal latency was measured in freely moving rats using plantar test apparatus. The aim of the experiment was to compare tail withdrawal latency measured by normal and modified tail-flick. The latencies were measured in intact animals, in animals under analgesia (baclofen 5 mg/kg i.p.) and under hyperalgesia (capsaicin induced acute inflammatory pain, surgical pain). The modified tail flick was tested on two frequently used intensities of the stimulation. It was shown that in intact animals the tail flick latency did not correspond with those of any intensity of the modified tail-flick test, it lied between them. Under analgesia, the withdrawal latencies significantly increased and tail-flick latencies corresponded with those of the lower intensity of the modified tail-flick test. Hyperalgesia models did not affect latencies of any method. It is concluded that modified tail-flick test can be used to measure analgesic effects of drugs and it may replace conventional tail flick test.
Comparison of two methods of tail flick latency measurement in rat
Lit.: 19
- 000
- 00000naa 2200000 a 4500
- 001
- bmc10036959
- 003
- CZ-PrNML
- 005
- 20111210201040.0
- 008
- 110118s2010 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Beran, Tomáš $7 xx0140225
- 245 10
- $a Srovnávání dvou metod měření termického prahu bolesti na ocasu laboratorního potkana / $c Tomáš Beran, Šimon Vaculín, Miloslav Franěk
- 246 11
- $a Comparison of two methods of tail flick latency measurement in rat
- 314 __
- $a 3. lékařská fakulta, Univerzita Karlova, Ústav normální, patologické a klinické fyziologie, Praha
- 504 __
- $a Lit.: 19
- 520 9_
- $a Intensive thermal stimulation of various skin areas is one of the most common behavioral pain-measurement methods used either in humans or in experimental animals. In tail-flick test, the thermal stimulation is focused on the dorsal surface of the tail in restrained animal, while in the plantar test, the stimulation is focused on the foot planta through a glass table in freely moving rats. We modified the tail-flick test in the way that the tail withdrawal latency was measured in freely moving rats using plantar test apparatus. The aim of the experiment was to compare tail withdrawal latency measured by normal and modified tail-flick. The latencies were measured in intact animals, in animals under analgesia (baclofen 5 mg/kg i.p.) and under hyperalgesia (capsaicin induced acute inflammatory pain, surgical pain). The modified tail flick was tested on two frequently used intensities of the stimulation. It was shown that in intact animals the tail flick latency did not correspond with those of any intensity of the modified tail-flick test, it lied between them. Under analgesia, the withdrawal latencies significantly increased and tail-flick latencies corresponded with those of the lower intensity of the modified tail-flick test. Hyperalgesia models did not affect latencies of any method. It is concluded that modified tail-flick test can be used to measure analgesic effects of drugs and it may replace conventional tail flick test.
- 650 _2
- $a práh bolesti $x klasifikace $x účinky léků $7 D017288
- 650 _2
- $a analgezie $x metody $x využití $7 D000698
- 650 _2
- $a hyperalgezie $x chemicky indukované $7 D006930
- 650 _2
- $a kapsaicin $x aplikace a dávkování $x metabolismus $7 D002211
- 650 _2
- $a baklofen $x aplikace a dávkování $7 D001418
- 650 _2
- $a měření bolesti $x metody $x veterinární $7 D010147
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a potkani Wistar $7 D017208
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a nocicepce $7 D059225
- 653 00
- $a tail flick test
- 653 00
- $a modifikovaný tail flick test
- 653 00
- $a plantar test
- 653 00
- $a potkan
- 655 _2
- $a srovnávací studie $7 D003160
- 700 1_
- $a Vaculín, Šimon, $d 1971- $7 mzk2009539443
- 700 1_
- $a Franěk, Miloslav, $d 1973- $7 xx0070726
- 773 0_
- $w MED00010962 $t Bolest $g Roč. 13, č. 3 (2010), s. 124-127 $x 1212-0634
- 856 41
- $u http://www.tigis.cz/images/stories/05_franek_web_zabezp.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 2028 $c 30 a $y 7
- 990 __
- $a 20110118084840 $b ABA008
- 991 __
- $a 20110902090925 $b ABA008
- 999 __
- $a ok $b bmc $g 825851 $s 690912
- BAS __
- $a 3
- BMC __
- $a 2010 $b 13 $c 3 $d 124-127 $m Bolest (Praha, Print) $x MED00010962
- LZP __
- $a 2011-02/mkmv