Matrix-less laser desorption/ionisation mass spectrometry of polyphenols in red wine

Z. Spáčil, M. Shariatgorji, N. Amini, P. Solich, L.L. Ilag

. 2009 ; 23 (12) : 1834-1840.

Language English Country Great Britain

Document type Evaluation Study, Research Support, Non-U.S. Gov't

Matrix-assisted laser desorption/ionisation (MALDI) of small molecules is challenging and in most cases impossible due to interferences from matrix ions precluding analysis of molecules <300-500 Da. A common matrix such as ferulic acid belongs to an important class of compounds associated with antioxidant activity. If the shared phenolic structure is related to the propensity as an active MALDI matrix then it follows that direct laser desorption/ionisation should be possible for polyphenols. Indeed matrix-less laser desorption/ionisation mass spectrometry is achieved whereby the analyte functions as a matrix and was used to monitor low molecular weight compounds in wine samples. Sensitivity ranging from 0.12-87 pmol/spot was achieved for eight phenolic acids (4-coumaric, 4-hydroxybenzoic, caffeic, ferulic, gallic, protocatechuic, syringic, vanillic) and 0.02 pmol/spot for trans-resveratrol. Additionally, 4-coumaric, 4-hydroxybenzoic, caffeic, ferulic, gallic, syringic, vanillic acids and trans-resveratrol were identified in wine samples using accurate mass measurements consistent with reported profiles based on liquid chromatography (LC)/MS. Minimal sample pre-treatment make the technique potentially appropriate for fingerprinting, screening and quality control of wine samples. Copyright (c) 2009 John Wiley & Sons, Ltd.

References provided by Crossref.org

000      
02667naa 2200313 a 4500
001      
bmc11017113
003      
CZ-PrNML
005      
20221005114816.0
008      
110629s2009 xxk e eng||
009      
AR
024    7_
$a 10.1002/rcm.4062 $2 doi
035    __
$a (PubMed)19444859
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Spáčil, Zdeněk, $d 1982- $7 mzk2007411147
245    10
$a Matrix-less laser desorption/ionisation mass spectrometry of polyphenols in red wine / $c Z. Spáčil, M. Shariatgorji, N. Amini, P. Solich, L.L. Ilag
314    __
$a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic.
520    9_
$a Matrix-assisted laser desorption/ionisation (MALDI) of small molecules is challenging and in most cases impossible due to interferences from matrix ions precluding analysis of molecules <300-500 Da. A common matrix such as ferulic acid belongs to an important class of compounds associated with antioxidant activity. If the shared phenolic structure is related to the propensity as an active MALDI matrix then it follows that direct laser desorption/ionisation should be possible for polyphenols. Indeed matrix-less laser desorption/ionisation mass spectrometry is achieved whereby the analyte functions as a matrix and was used to monitor low molecular weight compounds in wine samples. Sensitivity ranging from 0.12-87 pmol/spot was achieved for eight phenolic acids (4-coumaric, 4-hydroxybenzoic, caffeic, ferulic, gallic, protocatechuic, syringic, vanillic) and 0.02 pmol/spot for trans-resveratrol. Additionally, 4-coumaric, 4-hydroxybenzoic, caffeic, ferulic, gallic, syringic, vanillic acids and trans-resveratrol were identified in wine samples using accurate mass measurements consistent with reported profiles based on liquid chromatography (LC)/MS. Minimal sample pre-treatment make the technique potentially appropriate for fingerprinting, screening and quality control of wine samples. Copyright (c) 2009 John Wiley & Sons, Ltd.
590    __
$a bohemika - dle Pubmed
650    _2
$a flavonoidy $x chemie $7 D005419
650    _2
$a fenoly $x chemie $7 D010636
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a spektrometrie hmotnostní - ionizace laserem za účasti matrice $x metody $7 D019032
650    _2
$a víno $x analýza $7 D014920
655    _2
$a hodnotící studie $7 D023362
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Shariatgorji, Mohammadreza
700    1_
$a Amini, Nahid $7 gn_A_00005600
700    1_
$a Solich, Petr, $d 1955- $7 jo2007285395
700    1_
$a Ilag, Leopold L.
773    0_
$t Rapid Communications in Mass Spectrometry $w MED00004050 $g Roč. 23, č. 12 (2009), s. 1834-1840
910    __
$a ABA008 $b x $y 2 $z 0
990    __
$a 20110720101553 $b ABA008
991    __
$a 20221005114812 $b ABA008
999    __
$a ok $b bmc $g 864167 $s 726908
BAS    __
$a 3
BMC    __
$a 2009 $x MED00004050 $b 23 $c 12 $d 1834-1840 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom
LZP    __
$a 2011-3B09/BBjvme

Find record

Citation metrics

Loading data ...