-
Je něco špatně v tomto záznamu ?
Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes
M Novak, P Dvorak, P Kamaryt, B Slana, J Lipoldova
Jazyk angličtina Země Velká Británie
NLK
Free Medical Journals
od 1999 do Před 1 rokem
PubMed Central
od 2008
Open Access Digital Library
od 1999-01-01
Medline Complete (EBSCOhost)
od 1999-01-01
Oxford Journals Open Access Collection
od 1999-01-01
PubMed
19684037
DOI
10.1093/europace/eup216
Knihovny.cz E-zdroje
- MeSH
- defibrilátory implantabilní využití MeSH
- elektrická defibrilace mortalita přístrojové vybavení využití MeSH
- kardiostimulace umělá mortalita využití MeSH
- kardiostimulátor využití MeSH
- komorbidita MeSH
- lidé MeSH
- penetrující rány mortalita MeSH
- pitva statistika a číselné údaje MeSH
- poranění srdce mortalita MeSH
- selhání protézy MeSH
- senioři MeSH
- trombóza mortalita MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Geografické názvy
- Česká republika MeSH
AIMS: To evaluate intracardiac findings near leads and causes of death in pacemaker/defibrillator patients. METHODS AND RESULTS: Special autopsy was performed on 78 patients deceased in a hospital. Age at death was 77.9 +/- 10.0, implantation-death interval 4.0 +/- 3.3 years, ventricular leads n = 78, and atrial leads n = 21. Thrombi along leads in brachiocephalic vein/upper caval vein (BV/UCV) were found in 22 (7), in right atrium (RA) in 11 (8), and in right ventricle (RV) in 11 cases. Bipolar lead rings were fixed by fibrous tissue in 43 (4) cases. Connective tissue bridges and tunnels were found in BV/UCV in 44 (13), in RA in 17 (15), and in RV in 68 cases, with a length of 0.2-12.0 cm. Right ventricular leads in tricuspidal orifice were fixed by fibrous tissue in 11 and penetrating chordae in 25 cases. Main causes of death were: heart failure in 35, pulmonary embolism in 9, and myocardial infarction in 11 cases. CONCLUSION: We have found (i) thrombi on ventricular/atrial leads in 33/48%, (ii) bipolar lead rings fixed by fibrous tissue in 68/22%, (iii) connective tissue bridges or tunnels in ventricle/atrium in 87/71%, and (iv) ventricular leads fixed to valve or penetrating chordae in 46% of patients. We do recommend caution when extracting leads.
Citace poskytuje Crossref.org
- 000
- 03106naa a2200493 a 4500
- 001
- bmc12008561
- 003
- CZ-PrNML
- 005
- 20121122120757.0
- 008
- 120316s2009 xxk eng||
- 009
- AR
- 024 __
- $a 10.1093/europace/eup216 $2 doi
- 035 __
- $a (PubMed)19684037
- 040 __
- $a ABA008 $b cze $d ABA008
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Novák, Miroslav, $d 1958- $7 xx0079087 $u St Ann University Hospital, Masaryk University, Pekarska 53, Brno 65691, Czech Republic. miroslav.novak@fnusa.cz
- 245 10
- $a Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes / $c M Novak, P Dvorak, P Kamaryt, B Slana, J Lipoldova
- 520 9_
- $a AIMS: To evaluate intracardiac findings near leads and causes of death in pacemaker/defibrillator patients. METHODS AND RESULTS: Special autopsy was performed on 78 patients deceased in a hospital. Age at death was 77.9 +/- 10.0, implantation-death interval 4.0 +/- 3.3 years, ventricular leads n = 78, and atrial leads n = 21. Thrombi along leads in brachiocephalic vein/upper caval vein (BV/UCV) were found in 22 (7), in right atrium (RA) in 11 (8), and in right ventricle (RV) in 11 cases. Bipolar lead rings were fixed by fibrous tissue in 43 (4) cases. Connective tissue bridges and tunnels were found in BV/UCV in 44 (13), in RA in 17 (15), and in RV in 68 cases, with a length of 0.2-12.0 cm. Right ventricular leads in tricuspidal orifice were fixed by fibrous tissue in 11 and penetrating chordae in 25 cases. Main causes of death were: heart failure in 35, pulmonary embolism in 9, and myocardial infarction in 11 cases. CONCLUSION: We have found (i) thrombi on ventricular/atrial leads in 33/48%, (ii) bipolar lead rings fixed by fibrous tissue in 68/22%, (iii) connective tissue bridges or tunnels in ventricle/atrium in 87/71%, and (iv) ventricular leads fixed to valve or penetrating chordae in 46% of patients. We do recommend caution when extracting leads.
- 590 __
- $a bohemika - dle Pubmed
- 650 02
- $a senioři $7 D000368
- 650 02
- $a pitva $x statistika a číselné údaje $7 D001344
- 650 02
- $a kardiostimulace umělá $x mortalita $x využití $7 D002304
- 650 02
- $a komorbidita $7 D015897
- 650 02
- $a defibrilátory implantabilní $x využití $7 D017147
- 650 02
- $a elektrická defibrilace $x mortalita $x přístrojové vybavení $x využití $7 D004554
- 650 02
- $a ženské pohlaví $7 D005260
- 650 02
- $a poranění srdce $x mortalita $7 D006335
- 650 02
- $a lidé $7 D006801
- 650 02
- $a mužské pohlaví $7 D008297
- 650 02
- $a kardiostimulátor $x využití $7 D010138
- 650 02
- $a selhání protézy $7 D011475
- 650 02
- $a trombóza $x mortalita $7 D013927
- 650 02
- $a penetrující rány $x mortalita $7 D014950
- 651 _2
- $a Česká republika $x epidemiologie $7 D018153
- 700 1_
- $a Dvořák, Petr $7 xx0064554
- 700 1_
- $a Kamarýt, Pavel, $d 1932- $7 jk01052772
- 700 1_
- $a Slaná, Bronislava $7 xx0138315
- 700 1_
- $a Lipoldová, Jolana $7 xx0130589
- 773 0_
- $t Europace $p Europace $g Roč. 11, č. 11 (2009), s. 1510-1516 $w MED00149837 $x 1210-0668
- 773 0_
- $p Europace $g 11(11):1510-6, 2009 Nov
- 910 __
- $a ABA008 $b x $y 4
- 990 __
- $a 20120319124519 $b ABA008
- 991 __
- $a 20121122120819 $b ABA008
- 999 __
- $a ok $b bmc $g 901927 $s 765456
- BAS __
- $a 3
- BMC __
- $a 2009 $b 11 $c 11 $d 1510-1516 $m Europace $x MED00149837
- LZP __
- $a 2012-1Q10/jj