Something wrong with this record ?
Comparison of three single platform methods for CD34+ hematopoietic stem cell enumeration by flow cytometry
I. Marinov, A. Luxova, V. Tkacova, Z. Gasova, D. Pohlreich, P. Cetkovsky
Language English Country Germany
Document type Comparative Study, Evaluation Study, Journal Article
PubMed
22239039
Knihovny.cz E-resources
- MeSH
- Antigens, CD34 analysis immunology MeSH
- Bone Marrow Cells MeSH
- Dactinomycin analogs & derivatives MeSH
- Granulocyte Colony-Stimulating Factor pharmacology MeSH
- Fluorescein-5-isothiocyanate MeSH
- Fluorescent Dyes MeSH
- Phycoerythrin MeSH
- Hematopoietic Stem Cells MeSH
- Blood Cells MeSH
- Blood Cell Count MeSH
- Laboratories MeSH
- Leukapheresis MeSH
- Humans MeSH
- Hematopoietic Stem Cell Mobilization MeSH
- Antibodies, Monoclonal immunology MeSH
- Cell Count methods MeSH
- Antineoplastic Agents pharmacology MeSH
- Flow Cytometry methods MeSH
- Reproducibility of Results MeSH
- Sensitivity and Specificity MeSH
- Antibody Specificity MeSH
- Bone Marrow Examination MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Comparative Study MeSH
In the present study, we compared three single platform methods for CD34+ hematopoietic stem cell (HSC) enumeration by flow cytometry. For this purpose, we analyzed the performance characteristics and results obtained from different HSC sources. Interlaboratory coefficients of variation (CV) for precision/reproducibility analysis varied from 4.0% to 6.7% / 6.7% to 9.2% for the low and 3.2% to 4.1% / 4.3% to 6.7%, respectively, for the high stem cell control. Correlation between methods ranged from 0.92% to 0.99%; Wilcoxon test showed no significant differences (p > 0.05); Bland-Altman analysis confirmed good agreement between assays (mean bias ranging from -0.48 to 6.91). Our results demonstrate very good intralaboratory correlation and agreement between methods, confirm the major impact of single platform strategy for accurate and reproducible HSC enumeration and suggest that high interlaboratory variability could be influenced by incorrect performance of validated methods.
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12022185
- 003
- CZ-PrNML
- 005
- 20160304122531.0
- 007
- ta
- 008
- 120806s2011 gw f 000 0#eng||
- 009
- AR
- 035 __
- $a (PubMed)22239039
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Marinov, Iuri $u Institute of Hematology and Blood Transfusion, Prague, Czech Republic. $7 xx0018261
- 245 10
- $a Comparison of three single platform methods for CD34+ hematopoietic stem cell enumeration by flow cytometry / $c I. Marinov, A. Luxova, V. Tkacova, Z. Gasova, D. Pohlreich, P. Cetkovsky
- 520 9_
- $a In the present study, we compared three single platform methods for CD34+ hematopoietic stem cell (HSC) enumeration by flow cytometry. For this purpose, we analyzed the performance characteristics and results obtained from different HSC sources. Interlaboratory coefficients of variation (CV) for precision/reproducibility analysis varied from 4.0% to 6.7% / 6.7% to 9.2% for the low and 3.2% to 4.1% / 4.3% to 6.7%, respectively, for the high stem cell control. Correlation between methods ranged from 0.92% to 0.99%; Wilcoxon test showed no significant differences (p > 0.05); Bland-Altman analysis confirmed good agreement between assays (mean bias ranging from -0.48 to 6.91). Our results demonstrate very good intralaboratory correlation and agreement between methods, confirm the major impact of single platform strategy for accurate and reproducible HSC enumeration and suggest that high interlaboratory variability could be influenced by incorrect performance of validated methods.
- 650 _2
- $a monoklonální protilátky $x imunologie $7 D000911
- 650 _2
- $a specificita protilátek $7 D000918
- 650 _2
- $a antigeny CD34 $x analýza $x imunologie $7 D018952
- 650 _2
- $a protinádorové látky $x farmakologie $7 D000970
- 650 _2
- $a krevní obraz $7 D001772
- 650 _2
- $a krevní buňky $7 D001773
- 650 _2
- $a buňky kostní dřeně $7 D001854
- 650 _2
- $a vyšetřování kostní dřeně $7 D001856
- 650 _2
- $a počet buněk $x metody $7 D002452
- 650 _2
- $a daktinomycin $x analogy a deriváty $7 D003609
- 650 _2
- $a průtoková cytometrie $x metody $7 D005434
- 650 _2
- $a fluorescein-5-isothiokyanát $7 D016650
- 650 _2
- $a fluorescenční barviva $7 D005456
- 650 _2
- $a faktor stimulující kolonie granulocytů $x farmakologie $7 D016179
- 650 _2
- $a mobilizace hematopoetických kmenových buněk $7 D019650
- 650 _2
- $a hematopoetické kmenové buňky $7 D006412
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a laboratoře $7 D007753
- 650 _2
- $a leukaferéza $7 D007937
- 650 _2
- $a fykoerythrin $7 D010799
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a senzitivita a specificita $7 D012680
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Luxová, Alena $7 xx0139685
- 700 1_
- $a Tkáčová, Vlasta $7 _AN055388
- 700 1_
- $a Gašová, Zdenka $7 xx0061804
- 700 1_
- $a Pohlreich, David $7 xx0061820
- 700 1_
- $a Cetkovský, Petr, $d 1959- $7 xx0025652
- 773 0_
- $w MED00009480 $t Clinical laboratory $x 1433-6510 $g Roč. 57, č. 11-12 (2011), s. 1031-1035
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22239039 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120806 $b ABA008
- 991 __
- $a 20160304122543 $b ABA008
- 999 __
- $a ok $b bmc $g 944098 $s 779482
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 57 $c 11-12 $d 1031-1035 $i 1433-6510 $m Clinical laboratory $n Clin Lab $x MED00009480
- LZP __
- $b NLK111 $a Pubmed-20120806/12/01