-
Je něco špatně v tomto záznamu ?
High-performance liquid chromatographic method with amperometric detection employing boron-doped diamond electrode for the determination of sildenafil, vardenafil and their main metabolites in plasma
Z. Bartošová, D. Jirovský, A. Horna,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- bor chemie MeSH
- chromatografie s reverzní fází MeSH
- diamant chemie MeSH
- elektrody MeSH
- imidazoly krev chemie MeSH
- koncentrace vodíkových iontů MeSH
- lidé MeSH
- lineární modely MeSH
- piperaziny krev chemie MeSH
- puriny krev chemie MeSH
- senzitivita a specificita MeSH
- sulfony krev chemie MeSH
- triaziny krev chemie MeSH
- vysokoúčinná kapalinová chromatografie přístrojové vybavení metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A simple, fast and sensitive HPLC method with electrochemical detection employing boron-doped diamond electrode (BDD) for the determination of sildenafil (Viagra™), vardenafil (Levitra™) and their main metabolites, N-desmethyl sildenafil and N-desethyl vardenafil in human plasma is presented. The assay involved drug extraction by tert-butyl methyl ether and isocratic reversed-phase liquid chromatography with amperometric detection. Complete separation of all analytes was achieved within 12 min. The mobile phase consisted of 20mM sodium dihydrogen phosphate with 40 mM sodium perchlorate/acetonitrile (70:30, v/v), pH 3.5. The electrode working potential was +1520 mV (vs. Pd/H(2)). Calibration curves were linear over the concentration range of 10-400 ng mL(-1). Phloretin was used as an internal standard. The limits of detection (LOD) and quantification (LOQ) for the studied analytes were within the range of 2-4 ng mL(-1) and 7.0-13.4 ng mL(-1), respectively. The developed method was applied to human plasma samples spiked with analytes at therapeutic concentrations. The study confirms the method's suitability for both pharmacokinetic studies and therapeutic monitoring.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12022359
- 003
- CZ-PrNML
- 005
- 20120829112506.0
- 007
- ta
- 008
- 120806e20110908ne f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2011.09.001 $2 doi
- 035 __
- $a (PubMed)21943935
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Bartošová, Zdenka $u Department of Analytical Chemistry, Palacký University, 17. listopadu 12, CZ-771 46 Olomouc, Czech Republic.
- 245 10
- $a High-performance liquid chromatographic method with amperometric detection employing boron-doped diamond electrode for the determination of sildenafil, vardenafil and their main metabolites in plasma / $c Z. Bartošová, D. Jirovský, A. Horna,
- 504 __
- $a $b
- 520 9_
- $a A simple, fast and sensitive HPLC method with electrochemical detection employing boron-doped diamond electrode (BDD) for the determination of sildenafil (Viagra™), vardenafil (Levitra™) and their main metabolites, N-desmethyl sildenafil and N-desethyl vardenafil in human plasma is presented. The assay involved drug extraction by tert-butyl methyl ether and isocratic reversed-phase liquid chromatography with amperometric detection. Complete separation of all analytes was achieved within 12 min. The mobile phase consisted of 20mM sodium dihydrogen phosphate with 40 mM sodium perchlorate/acetonitrile (70:30, v/v), pH 3.5. The electrode working potential was +1520 mV (vs. Pd/H(2)). Calibration curves were linear over the concentration range of 10-400 ng mL(-1). Phloretin was used as an internal standard. The limits of detection (LOD) and quantification (LOQ) for the studied analytes were within the range of 2-4 ng mL(-1) and 7.0-13.4 ng mL(-1), respectively. The developed method was applied to human plasma samples spiked with analytes at therapeutic concentrations. The study confirms the method's suitability for both pharmacokinetic studies and therapeutic monitoring.
- 650 _2
- $a bor $x chemie $7 D001895
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x přístrojové vybavení $x metody $7 D002851
- 650 _2
- $a chromatografie s reverzní fází $7 D056148
- 650 _2
- $a diamant $x chemie $7 D018130
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a imidazoly $x krev $x chemie $7 D007093
- 650 _2
- $a lineární modely $7 D016014
- 650 _2
- $a piperaziny $x krev $x chemie $7 D010879
- 650 _2
- $a puriny $x krev $x chemie $7 D011687
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a sulfony $x krev $x chemie $7 D013450
- 650 _2
- $a triaziny $x krev $x chemie $7 D014227
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Jirovský, David
- 700 1_
- $a Horna, Aleš
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1218, č. 44 (20110908), s. 7996-8001
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21943935 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120806 $b ABA008
- 991 __
- $a 20120829112630 $b ABA008
- 999 __
- $a ok $b bmc $g 944272 $s 779656
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 1218 $c 44 $d 7996-8001 $e 20110908 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20120806/12/01