• Je něco špatně v tomto záznamu ?

The effect of a cardiopulmonary bypass system with biocompatible coating on fibrinogen levels determined by the TEG--functional fibrinogen method: preliminary results

I. Fluger, K. Maderová, M. Simek, R. Hájek, J. Zapletalová, V. Lonsky,

. 2011 ; 26 (6) : 503-9. [pub] 20110708

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12022541

Grantová podpora
NS9614 MZ0 CEP - Centrální evidence projektů

Digitální knihovna NLK
Plný text - Článek
Zdroj

E-zdroje Online Plný text

NLK ProQuest Central od 1997-01-01 do 2015-11-30
SAGE Publications Journals od 1999-01-01 do 2015-12-31
CINAHL Plus with Full Text (EBSCOhost) od 1997-01-01 do 2016-05-31
Medline Complete (EBSCOhost) od 1997-01-01 do 2016-05-31
Nursing & Allied Health Database (ProQuest) od 1997-01-01 do 2015-11-30
Health & Medicine (ProQuest) od 1997-01-01 do 2015-11-30

When cardiopulmonary bypass (CPB) is used, the blood comes into contact with foreign surfaces. To diminish this impact, various types of biocompatibly coated surfaces have been developed. The study assessed the effects of heparin-coated CPB systems on the level and function of fibrinogen as measured by thromboelastography (TEG), as compared with non-coated systems. No statistically significant differences between both groups were revealed by comparing paired data. In our study, heparin-coated CPB circuits had no significant effect on either fibrinogen level or its function.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12022541
003      
CZ-PrNML
005      
20140924120753.0
007      
ta
008      
120806e20110708xxk f 000 0#eng||
009      
AR
024    7_
$a 10.1177/0267659111415891 $2 doi
035    __
$a (PubMed)21742756
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Fluger, I $u Department of Cardiac Surgery, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic. iflug@t-email.cz
245    14
$a The effect of a cardiopulmonary bypass system with biocompatible coating on fibrinogen levels determined by the TEG--functional fibrinogen method: preliminary results / $c I. Fluger, K. Maderová, M. Simek, R. Hájek, J. Zapletalová, V. Lonsky,
520    9_
$a When cardiopulmonary bypass (CPB) is used, the blood comes into contact with foreign surfaces. To diminish this impact, various types of biocompatibly coated surfaces have been developed. The study assessed the effects of heparin-coated CPB systems on the level and function of fibrinogen as measured by thromboelastography (TEG), as compared with non-coated systems. No statistically significant differences between both groups were revealed by comparing paired data. In our study, heparin-coated CPB circuits had no significant effect on either fibrinogen level or its function.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a kardiopulmonální bypass $x přístrojové vybavení $7 D002315
650    _2
$a biokompatibilní potahované materiály $x metabolismus $7 D020099
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a fibrinogen $x metabolismus $7 D005340
650    _2
$a heparin $x metabolismus $7 D006493
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a tromboelastografie $7 D013916
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Maderová, K
700    1_
$a Simek, M
700    1_
$a Hájek, R
700    1_
$a Zapletalová, J
700    1_
$a Lonsky, V
773    0_
$w MED00003752 $t Perfusion $x 1477-111X $g Roč. 26, č. 6 (20110708), s. 503-9
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21742756 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m $z 0
990    __
$a 20120806 $b ABA008
991    __
$a 20140924121213 $b ABA008
999    __
$a ok $b bmc $g 944454 $s 779838
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 26 $c 6 $d 503-9 $e 20110708 $i 1477-111X $m Perfusion $n Perfusion $x MED00003752
GRA    __
$a NS9614 $p MZ0
LZP    __
$a Pubmed-20120806/12/01

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace