Simultaneous analysis of cocaine and its metabolites in urine by capillary electrophoresis-electrospray mass spectrometry using a pressurized liquid junction nanoflow interface

V. Hezinová, Z. Aturki, K. Klepárník, G. D'Orazio, F. Foret, S. Fanali,

. 2012 ; 33 (4) : 653-60.

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12023979

A new method for the simultaneous separation of cocaine and four metabolites in urine by CE-ESI-MS via a pressurized nanoliquid junction interface was developed. The resolution of cocaine, cocaethylene, benzoylecgonine, norcocaine, and ecgonine methyl ester was achieved in a polyvinyl-alcohol-coated capillary with 75 μm id × 50 cm total length, using a 15 mM ammonium formate electrolyte solution (pH 9.5) in less than 15 min. In addition, to enhance sensitivity, a field-amplified sample injection (FASI) was evaluated in terms of injection time and sample solvent composition. The limits of detection achieved with the FASI method ranged from 1.5 to 10 ng/mL for all the compounds. The detection of the studied compounds was performed using an ion-trap mass spectrometer in a positive ionization mode. A mixture of methanol:water (80:20 v/v) containing 0.1% v/v of formic acid was employed as spray liquid and delivered at ~200 nL/min. Under optimal CE-MS conditions, linearity was assessed in the concentration range of interest for all analytes with correlation coefficients r² ≥ 0.9913. Intra- and inter-day precision provided a relative standard deviation lower than 1.54% for migration times and lower than 12.15% for peak areas. Finally, urine samples, spiked with the standard mixture, were extracted using a solid-phase extraction procedure and injected under FASI conditions, providing recoveries from 80% to 94% for all analytes.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12023979
003      
CZ-PrNML
005      
20121207095536.0
007      
ta
008      
120815s2012 gw f 000 0#eng||
009      
AR
024    7_
$a 10.1002/elps.201100410 $2 doi
035    __
$a (PubMed)22451058
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Hezinová, Věra $u Institute of Analytical Chemistry, Czech Academy of Sciences, Brno, Czech Republic.
245    10
$a Simultaneous analysis of cocaine and its metabolites in urine by capillary electrophoresis-electrospray mass spectrometry using a pressurized liquid junction nanoflow interface / $c V. Hezinová, Z. Aturki, K. Klepárník, G. D'Orazio, F. Foret, S. Fanali,
520    9_
$a A new method for the simultaneous separation of cocaine and four metabolites in urine by CE-ESI-MS via a pressurized nanoliquid junction interface was developed. The resolution of cocaine, cocaethylene, benzoylecgonine, norcocaine, and ecgonine methyl ester was achieved in a polyvinyl-alcohol-coated capillary with 75 μm id × 50 cm total length, using a 15 mM ammonium formate electrolyte solution (pH 9.5) in less than 15 min. In addition, to enhance sensitivity, a field-amplified sample injection (FASI) was evaluated in terms of injection time and sample solvent composition. The limits of detection achieved with the FASI method ranged from 1.5 to 10 ng/mL for all the compounds. The detection of the studied compounds was performed using an ion-trap mass spectrometer in a positive ionization mode. A mixture of methanol:water (80:20 v/v) containing 0.1% v/v of formic acid was employed as spray liquid and delivered at ~200 nL/min. Under optimal CE-MS conditions, linearity was assessed in the concentration range of interest for all analytes with correlation coefficients r² ≥ 0.9913. Intra- and inter-day precision provided a relative standard deviation lower than 1.54% for migration times and lower than 12.15% for peak areas. Finally, urine samples, spiked with the standard mixture, were extracted using a solid-phase extraction procedure and injected under FASI conditions, providing recoveries from 80% to 94% for all analytes.
650    _2
$a kokain $x metabolismus $x moč $7 D003042
650    _2
$a elektroforéza kapilární $x přístrojové vybavení $x metody $7 D019075
650    _2
$a lidé $7 D006801
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a nanotechnologie $x přístrojové vybavení $x metody $7 D036103
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $x přístrojové vybavení $x metody $7 D021241
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Aturki, Zeineb $7 gn_A_00009883
700    1_
$a Klepárník, Karel
700    1_
$a D'Orazio, Giovanni
700    1_
$a Foret, František
700    1_
$a Fanali, Salvatore
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 33, č. 4 (2012), s. 653-60
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22451058 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120815 $b ABA008
991    __
$a 20121207095611 $b ABA008
999    __
$a ok $b bmc $g 946127 $s 781307
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 33 $c 4 $d 653-60 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
LZP    __
$a Pubmed-20120815/12/02

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...