• Je něco špatně v tomto záznamu ?

Attachments of muscles as landmarks for implantation of shoulder hemiarthoplasty in fractures

R. Hromádka, A.A. Kubena, D. Pokorný, S. Popelka, D. Jahoda, A. Sosna

. 2010 ; 19 (1) : 130-136.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc12025568

BACKGROUND: The attachments of muscles and the position of the humeral head are important for a good functional outcome of shoulder hemiarthroplasties after displaced fractures of the proximal humerus. Deviations in the attachments and changes in their spatial position with respect to the humeral head during surgical reconstruction change the biomechanics and reduce the range of motion of the should joint postoperatively. METHODS AND RESULTS: We used 198 humerus preparations and using 3-dimensional analysis measured the angular relationships between the humeral head axis and medial margin of the greater tuberosity (11.9 degrees +/- 9.1 degrees ), lateral margin of the lesser tuberosity (48.0 degrees +/- 7.8 degrees ), and the crest of the greater tuberosity (27.1 degrees +/- 9.6 degrees ). CONCLUSION: This study provides average values of the positions of the greater and lesser tuberosities with respect to the humeral head axis. We show that the greater and lesser tuberosities are more reliable than the transepicondylar line for reconstruction of humeral head retroversion. LEVEL OF EVIDENCE: Basic Science.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12025568
003      
CZ-PrNML
005      
20200630131035.0
007      
ta
008      
120816s2010 xxu f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.jse.2009.03.023 $2 doi
035    __
$a (PubMed)19525130
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Hromádka, Rastislav, $d 1975- $7 xx0093688 $u 1(St) Orthopaedic Clinic, 1(St) Faculty of Medicine, Charles University in Prague, Czech Republic. rastislav.hromadka@lf1.cuni.cz
245    10
$a Attachments of muscles as landmarks for implantation of shoulder hemiarthoplasty in fractures / $c R. Hromádka, A.A. Kubena, D. Pokorný, S. Popelka, D. Jahoda, A. Sosna
520    9_
$a BACKGROUND: The attachments of muscles and the position of the humeral head are important for a good functional outcome of shoulder hemiarthroplasties after displaced fractures of the proximal humerus. Deviations in the attachments and changes in their spatial position with respect to the humeral head during surgical reconstruction change the biomechanics and reduce the range of motion of the should joint postoperatively. METHODS AND RESULTS: We used 198 humerus preparations and using 3-dimensional analysis measured the angular relationships between the humeral head axis and medial margin of the greater tuberosity (11.9 degrees +/- 9.1 degrees ), lateral margin of the lesser tuberosity (48.0 degrees +/- 7.8 degrees ), and the crest of the greater tuberosity (27.1 degrees +/- 9.6 degrees ). CONCLUSION: This study provides average values of the positions of the greater and lesser tuberosities with respect to the humeral head axis. We show that the greater and lesser tuberosities are more reliable than the transepicondylar line for reconstruction of humeral head retroversion. LEVEL OF EVIDENCE: Basic Science.
650    _2
$a analýza rozptylu $7 D000704
650    _2
$a artroplastiky kloubů $x metody $7 D019643
650    _2
$a biomechanika $7 D001696
650    _2
$a lidé $7 D006801
650    _2
$a humerus $x anatomie a histologie $x chirurgie $7 D006811
650    _2
$a počítačové zpracování obrazu $7 D007091
650    _2
$a zobrazování trojrozměrné $7 D021621
650    _2
$a magnetická rezonanční tomografie $7 D008279
650    _2
$a anatomické modely $7 D008953
650    _2
$a kosterní svaly $x anatomie a histologie $x chirurgie $7 D018482
650    _2
$a pravděpodobnost $7 D011336
650    _2
$a protézy - design $7 D011474
650    _2
$a protetické vybavení $7 D017755
650    _2
$a rotátorová manžeta $x anatomie a histologie $x radiografie $7 D017006
650    _2
$a fraktury proximálního humeru $x radiografie $x chirurgie $7 D012784
650    _2
$a počítačová rentgenová tomografie $7 D014057
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kuběna, Aleš $7 xx0108674
700    1_
$a Pokorný, David, $d 1968- $7 jn20001103568
700    1_
$a Popelka, Stanislav $7 xx0098390
700    1_
$a Jahoda, David $7 xx0014721
700    1_
$a Sosna, Antonín, $d 1943- $7 jn20000710566
773    0_
$w MED00005004 $t Journal of shoulder and elbow surgery American Shoulder and Elbow Surgeons ... [et al.] $x 1532-6500 $g Roč. 19, č. 1 (2010), s. 130-136
856    41
$u https://pubmed.ncbi.nlm.nih.gov/19525130 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m $z 0
990    __
$a 20120816 $b ABA008
991    __
$a 20200630131031 $b ABA008
999    __
$a ok $b bmc $g 947610 $s 782914
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 19 $c 1 $d 130-136 $i 1532-6500 $m Journal of shoulder and elbow surgery $n J Shoulder Elbow Surg $x MED00005004
LZP    __
$a Pubmed-20120816/10/02

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace