Surface plasmon resonance biosensor for parallelized detection of protein biomarkers in diluted blood plasma

M. Piliarik, M. Bocková, J. Homola

. 2010 ; 26 (4) : 1656-1661.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12027349

Surface plasmon resonance (SPR) biosensor for high-throughput screening of protein biomarkers in diluted blood plasma is reported. The biosensor combines a high-resolution SPR imaging sensor and a high-density protein array with low-fouling background. The SPR imaging sensor utilizes polarization contrast and advanced referencing and provides a total of 120 sensing areas (each 200 μm×150 μm). Antibodies are immobilized on the sensing areas via hybridization of antibody-oligonucleotide conjugates to thiolated complementary oligonucleotides microspotted on the sensor surface (DNA-directed immobilization). A low-fouling background is achieved by covalent immobilization of bovine serum albumin to carboxyl-terminated thiols filling the areas among the thiolated oligonucleotides and outside the sensing areas. The biosensor was evaluated for detection of protein biomarkers relevant to cancer diagnostics--human chorionic gonadotropin (hCG) and activated leukocyte cell adhesion molecule (ALCAM) both in buffer and in 10% blood plasma. Limits of detection as low as 45 ng/mL (ALCAM) and 100 ng/mL (hCG) were achieved in blood plasma samples.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12027349
003      
CZ-PrNML
005      
20160302155931.0
007      
ta
008      
120816s2010 enk f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.bios.2010.08.063 $2 doi
035    __
$a (PubMed)20864329
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Piliarik, Marek $u Institute of Photonics and Electronics AS CR v.v.i., Chaberská 57, CZ-18251 Prague 8, Czech Republic
245    10
$a Surface plasmon resonance biosensor for parallelized detection of protein biomarkers in diluted blood plasma / $c M. Piliarik, M. Bocková, J. Homola
520    9_
$a Surface plasmon resonance (SPR) biosensor for high-throughput screening of protein biomarkers in diluted blood plasma is reported. The biosensor combines a high-resolution SPR imaging sensor and a high-density protein array with low-fouling background. The SPR imaging sensor utilizes polarization contrast and advanced referencing and provides a total of 120 sensing areas (each 200 μm×150 μm). Antibodies are immobilized on the sensing areas via hybridization of antibody-oligonucleotide conjugates to thiolated complementary oligonucleotides microspotted on the sensor surface (DNA-directed immobilization). A low-fouling background is achieved by covalent immobilization of bovine serum albumin to carboxyl-terminated thiols filling the areas among the thiolated oligonucleotides and outside the sensing areas. The biosensor was evaluated for detection of protein biomarkers relevant to cancer diagnostics--human chorionic gonadotropin (hCG) and activated leukocyte cell adhesion molecule (ALCAM) both in buffer and in 10% blood plasma. Limits of detection as low as 45 ng/mL (ALCAM) and 100 ng/mL (hCG) were achieved in blood plasma samples.
650    _2
$a zvířata $7 D000818
650    _2
$a imobilizační protilátky $7 D055910
650    _2
$a CD antigeny $x krev $7 D015703
650    _2
$a biologické markery $x krev $7 D015415
650    _2
$a krevní proteiny $x analýza $7 D001798
650    _2
$a skot $7 D002417
650    _2
$a molekuly buněčné adheze neuronové $x krev $7 D015816
650    _2
$a choriogonadotropin $x krev $7 D006063
650    _2
$a design vybavení $7 D004867
650    _2
$a fetální proteiny $7 D005326
650    _2
$a lidé $7 D006801
650    _2
$a imobilizované proteiny $7 D055767
650    _2
$a limita detekce $7 D057230
650    _2
$a nádory $x krev $x diagnóza $7 D009369
650    _2
$a oligonukleotidy $7 D009841
650    _2
$a refraktometrie $7 D012031
650    _2
$a sérový albumin hovězí $7 D012710
650    _2
$a povrchová plasmonová rezonance $x přístrojové vybavení $x metody $x statistika a číselné údaje $7 D020349
650    _2
$a thionukleotidy $7 D013873
650    _2
$a nádorové biomarkery $x krev $7 D014408
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Bocková, Markéta $7 xx0261195 $u Institute of Photonics and Electronics AS CR v.v.i., Chaberská 57, CZ-18251 Prague 8, Czech Republic
700    1_
$a Homola, Jiří $7 xx0039276 $u Institute of Photonics and Electronics AS CR v.v.i., Chaberská 57, CZ-18251 Prague 8, Czech Republic
773    0_
$w MED00006627 $t Biosensors & bioelectronics $x 1873-4235 $g Roč. 26, č. 4 (2010), s. 1656-1661
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20864329 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m $z 0
990    __
$a 20120816 $b ABA008
991    __
$a 20160302155649 $b ABA008
999    __
$a ok $b bmc $g 949391 $s 784695
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 26 $c 4 $d 1656-1661 $i 1873-4235 $m Biosensors & bioelectronics $n Biosens Bioelectron $x MED00006627
LZP    __
$b NLK112 $a Pubmed-20120816/11/02

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...