-
Something wrong with this record ?
Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution
J. Ferda, E. Ferdová, H. Mírka, J. Baxa, A. Bednářová, T. Flohr, B. Schmidt, M. Matějovič, B. Kreuzberg
Language English Country Ireland
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Angiography methods MeSH
- Adult MeSH
- Iodine diagnostic use pharmacokinetics MeSH
- Contrast Media pharmacokinetics MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Perfusion Imaging methods MeSH
- Pulmonary Embolism metabolism MeSH
- Tomography, X-Ray Computed methods MeSH
- Radiography, Dual-Energy Scanned Projection methods MeSH
- Reproducibility of Results MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Sensitivity and Specificity MeSH
- Air analysis MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
AIM: The aim of the study is to present the feasibility of using dual-energy CT and the evaluation of iodine and air distribution in differentiation of pathological conditions. MATERIAL AND METHOD: We used the data of 50 CT examinations performed due to suspected pulmonary embolism with any pathological finding except consolidation of the parenchyma. The patients underwent CT angiography of the pulmonary arteries on a dual-source CT (DSCT), with the two tubes independently operated at 140 and 80 kV. By exploiting the dual-energy information, iodine distribution maps were obtained in addition to the conventional CT images which served as a marker of pulmonary perfusion. Minimum intensity projections (MinIP) were used as a marker of air content. RESULTS: By comparing the iodine distribution maps and MinIP images, it was possible to differentiate between the following templates of lung parenchyma: A--normal iodine and air distribution; B--iodine content deficit with minimal or with no redistribution of air; C--reduced iodine content and increased content of air; D--deficit of iodine content and increased content of air; E--increased iodine content and normal content of air; F--increased iodine content and reduced content of air; G--reduced perfusion and reduced content of air. The type A (five cases) was typical for the pulmonary embolism with preserved normal conditions of perfusion and ventilation. Type B (18 cases) occurred in pulmonary embolism; type C was found in case of inflammation of small respiratory airways (five cases); emphysema was typical for type D (nine cases); increased perfusion was observed in the parenchyma preserved from emphysema or preserved from embolism in cases of emphysema or pulmonary embolism; type F occurred in pulmonary interstitial edema (four cases) both with pulmonary infection; finally type G was found in interstitial lung diseases (five cases). CONCLUSION: Imaging of the pulmonary circulation by means of dual-energy CT opens the potential to study pathological changes of circulatory and pulmonary perfusion impairments, our presented work signs the important relations between iodine and air distribution which have to be thought in the interpretation of dual-energy perfusion imaging of the lungs.
http www ncbi nlm nih gov pubmed 19717260
Siemens Healthcare Computed Tomography 91301 Siemensstr 1 Forchheim Germany
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12027443
- 003
- CZ-PrNML
- 005
- 20160224133830.0
- 007
- ta
- 008
- 120816s2011 ie f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.ejrad.2009.08.005 $2 doi
- 035 __
- $a (PubMed)19717260
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ie
- 100 1_
- $a Ferda, Jiří, $u Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzeň, Czech Republic. e-mail@fnplzen.cz $d 1970- $7 nlk20040148200
- 245 10
- $a Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution / $c J. Ferda, E. Ferdová, H. Mírka, J. Baxa, A. Bednářová, T. Flohr, B. Schmidt, M. Matějovič, B. Kreuzberg
- 520 9_
- $a AIM: The aim of the study is to present the feasibility of using dual-energy CT and the evaluation of iodine and air distribution in differentiation of pathological conditions. MATERIAL AND METHOD: We used the data of 50 CT examinations performed due to suspected pulmonary embolism with any pathological finding except consolidation of the parenchyma. The patients underwent CT angiography of the pulmonary arteries on a dual-source CT (DSCT), with the two tubes independently operated at 140 and 80 kV. By exploiting the dual-energy information, iodine distribution maps were obtained in addition to the conventional CT images which served as a marker of pulmonary perfusion. Minimum intensity projections (MinIP) were used as a marker of air content. RESULTS: By comparing the iodine distribution maps and MinIP images, it was possible to differentiate between the following templates of lung parenchyma: A--normal iodine and air distribution; B--iodine content deficit with minimal or with no redistribution of air; C--reduced iodine content and increased content of air; D--deficit of iodine content and increased content of air; E--increased iodine content and normal content of air; F--increased iodine content and reduced content of air; G--reduced perfusion and reduced content of air. The type A (five cases) was typical for the pulmonary embolism with preserved normal conditions of perfusion and ventilation. Type B (18 cases) occurred in pulmonary embolism; type C was found in case of inflammation of small respiratory airways (five cases); emphysema was typical for type D (nine cases); increased perfusion was observed in the parenchyma preserved from emphysema or preserved from embolism in cases of emphysema or pulmonary embolism; type F occurred in pulmonary interstitial edema (four cases) both with pulmonary infection; finally type G was found in interstitial lung diseases (five cases). CONCLUSION: Imaging of the pulmonary circulation by means of dual-energy CT opens the potential to study pathological changes of circulatory and pulmonary perfusion impairments, our presented work signs the important relations between iodine and air distribution which have to be thought in the interpretation of dual-energy perfusion imaging of the lungs.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a vzduch $x analýza $7 D000388
- 650 _2
- $a angiografie $x metody $7 D000792
- 650 _2
- $a kontrastní látky $x farmakokinetika $7 D003287
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a jod $x diagnostické užití $x farmakokinetika $7 D007455
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a perfuzní zobrazování $x metody $7 D055420
- 650 _2
- $a plicní embolie $x metabolismus $7 D011655
- 650 _2
- $a rentgendiagnostika - dvourozměrná projekce $x metody $7 D015900
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a počítačová rentgenová tomografie $x metody $7 D014057
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Ferdová, Eva $u http://www.ncbi.nlm.nih.gov/pubmed/19717260 $7 xx0074227
- 700 1_
- $a Mírka, Hynek, $d 1971- $u Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzeň, Czech Republic $7 nlk20040148203
- 700 1_
- $a Baxa, Jan, $d 1980- $u Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzeň, Czech Republic $7 mzk2009512901
- 700 1_
- $a Bednářová, Alena $7 _BN006086 $u Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzeň, Czech Republic
- 700 1_
- $a Flohr, Thomas $u Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzeň, Czech Republic
- 700 1_
- $a Schmidt, Bernhard $u Siemens Healthcare, Computed Tomography, 91301 Siemensstr. 1, Forchheim, Germany
- 700 1_
- $a Matějovič, Martin, $d 1969- $u 1st Internal Department, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzeň, Czech Republic $7 nlk20030138334
- 700 1_
- $a Kreuzberg, Boris, $d 1950- $u Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzeň, Czech Republic $7 jn20000603556
- 773 0_
- $w MED00009640 $t European journal of radiology $x 1872-7727 $g Roč. 77, č. 2 (2011), s. 287-293
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/19717260 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120816 $b ABA008
- 991 __
- $a 20160224133546 $b ABA008
- 999 __
- $a ok $b bmc $g 949485 $s 784789
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 77 $c 2 $d 287-293 $i 1872-7727 $m European journal of radiology $n Eur J Radiol $x MED00009640
- LZP __
- $b NLK112 $a Pubmed-20120816/11/02