-
Something wrong with this record ?
Influence of demographic, surgical and implant variables on wear rate and osteolysis in ABG I hip arthroplasty
J. Gallo, V. Havranek, I. Cechova, J. Zapletalova
Language English Country Czech Republic
Document type Journal Article
NLK
Directory of Open Access Journals
from 2001
Free Medical Journals
from 1998
ROAD: Directory of Open Access Scholarly Resources
from 2001
PubMed
16936917
DOI
10.5507/bp.2006.021
Knihovny.cz E-resources
- MeSH
- Acetabulum pathology MeSH
- Adult MeSH
- Femur Head MeSH
- Hip Prosthesis MeSH
- Middle Aged MeSH
- Humans MeSH
- Arthroplasty, Replacement, Hip MeSH
- Osteolysis etiology pathology MeSH
- Polyethylene MeSH
- Reoperation MeSH
- Prosthesis Failure MeSH
- Aged MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
Periprosthetic osteolysis is associated with accelerated wear rates. The goal of this study was to investigate the influence of demographic and technical variables on wear rates and size of osteolytic lesions. Eighty retrieved ABG I prostheses were analyzed according to prospectively established criteria. There were 22 men and 58 women with an average age of 52 years (34-65) at the time of revision. The average time from index surgery to revision was 67 months (26 to 106). Polyethylene wear measurements were performed using a Universal-type measuring microscope. The average linear wear and volumetric wear rate was 0.363 mm per year (0-0.939, SD 0.241) and 161 mm(3) per year (0-467, SD 118.2), respectively. The wear rates were significantly higher (a) in patients with primary osteoarthritis in comparison with postdysplastic hips, (b) in hips where zirconia prosthetic heads articulated against the polyethylene liner, and (c) in cups placed laterally to Kohler's line. Risk that linear wear rate could be more than 0.2 mm per year was three times higher in patients who were operated in 1997 and later (OR 3.0, 95 % CI 1.126-7.993, p = 0.03). A strong association was revealed between magnitude of wear and size of femoral osteolysis.
Department of Biophysics Faculty of Medicine Palacky University Olomouc
Department of Orthopaedics Faculty of Medicine Palacký University University Hospital Olomouc
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13003685
- 003
- CZ-PrNML
- 005
- 20130212154722.0
- 007
- ta
- 008
- 130128s2006 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2006.021 $2 doi
- 035 __
- $a (PubMed)16936917
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Gallo, Jiří $7 xx0019005 $u Department of Orthopaedics, Faculty of Medicine Palacký University, University Hospital, Olomouc
- 245 10
- $a Influence of demographic, surgical and implant variables on wear rate and osteolysis in ABG I hip arthroplasty / $c J. Gallo, V. Havranek, I. Cechova, J. Zapletalova
- 520 9_
- $a Periprosthetic osteolysis is associated with accelerated wear rates. The goal of this study was to investigate the influence of demographic and technical variables on wear rates and size of osteolytic lesions. Eighty retrieved ABG I prostheses were analyzed according to prospectively established criteria. There were 22 men and 58 women with an average age of 52 years (34-65) at the time of revision. The average time from index surgery to revision was 67 months (26 to 106). Polyethylene wear measurements were performed using a Universal-type measuring microscope. The average linear wear and volumetric wear rate was 0.363 mm per year (0-0.939, SD 0.241) and 161 mm(3) per year (0-467, SD 118.2), respectively. The wear rates were significantly higher (a) in patients with primary osteoarthritis in comparison with postdysplastic hips, (b) in hips where zirconia prosthetic heads articulated against the polyethylene liner, and (c) in cups placed laterally to Kohler's line. Risk that linear wear rate could be more than 0.2 mm per year was three times higher in patients who were operated in 1997 and later (OR 3.0, 95 % CI 1.126-7.993, p = 0.03). A strong association was revealed between magnitude of wear and size of femoral osteolysis.
- 650 _2
- $a acetabulum $x patologie $7 D000077
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a náhrada kyčelního kloubu $7 D019644
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a hlavice femuru $7 D005270
- 650 _2
- $a kyčelní protézy $7 D006622
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a osteolýza $x etiologie $x patologie $7 D010014
- 650 _2
- $a polyethylen $7 D020959
- 650 _2
- $a selhání protézy $7 D011475
- 650 _2
- $a reoperace $7 D012086
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Havránek, Vítězslav. $7 _AN047673 $u Joint Laboratory of Optics, Faculty of Science Palacky University & Academy of Sciences of the Czech Republic, Olomouc
- 700 1_
- $a Čechová, Ivana $7 xx0093685 $u Department of Orthopaedics, Faculty of Medicine Palacký University, University Hospital, Olomouc
- 700 1_
- $a Zapletalová, Jana $7 xx0111614 $u Department of Biophysics, Faculty of Medicine Palacky University, Olomouc
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 150, č. 1 (2006), s. 135-141
- 910 __
- $a ABA008 $b A 1502 $c sign $y 3 $z 0
- 990 __
- $a 20130128 $b ABA008
- 991 __
- $a 20130212154904 $b ABA008
- 999 __
- $a ok $b bmc $g 966341 $s 801880
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2006 $b 150 $c 1 $d 135-141 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- LZP __
- $b NLK111 $a Pubmed-20130128