• Je něco špatně v tomto záznamu ?

Analysis of internal astigmatism and higher order aberrations in eyes implanted with a new diffractive multifocal toric intraocular lens

P. Mojzis, DP. Piñero, V. Ctvrteckova, I. Rydlova,

. 2013 ; 251 (1) : 341-8.

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc13024432
E-zdroje Online Plný text

NLK ProQuest Central od 1997-10-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2009-07-01 do Před 1 rokem
Health & Medicine (ProQuest) od 1997-10-01 do Před 1 rokem

BACKGROUND: To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL METHODS: Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). RESULTS: A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. CONCLUSIONS: The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13024432
003      
CZ-PrNML
005      
20130710091600.0
007      
ta
008      
130703s2013 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00417-012-2061-1 $2 doi
035    __
$a (PubMed)22588290
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Mojzis, Peter $u Eye Department, Regional Hospital, Havlickuv Brod, Czech Republic.
245    10
$a Analysis of internal astigmatism and higher order aberrations in eyes implanted with a new diffractive multifocal toric intraocular lens / $c P. Mojzis, DP. Piñero, V. Ctvrteckova, I. Rydlova,
520    9_
$a BACKGROUND: To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL METHODS: Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). RESULTS: A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. CONCLUSIONS: The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.
650    _2
$a aberometrie $7 D057128
650    _2
$a dospělí $7 D000328
650    _2
$a astigmatismus $x diagnóza $x chirurgie $7 D001251
650    _2
$a rohovková topografie $7 D019781
650    _2
$a rohovkové aberace $x diagnóza $x chirurgie $7 D057108
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    12
$a implantace nitrooční čočky $7 D019654
650    12
$a nitrooční čočky $7 D007910
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    12
$a fakoemulzifikace $7 D018918
650    _2
$a prospektivní studie $7 D011446
650    _2
$a protézy - design $7 D011474
650    _2
$a pseudofakie $x patofyziologie $7 D019591
650    _2
$a refrakce oka $x fyziologie $7 D012029
650    _2
$a zraková ostrost $x fyziologie $7 D014792
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
700    1_
$a Piñero, David P $u -
700    1_
$a Ctvrteckova, Vera $u -
700    1_
$a Rydlova, Iva $u -
773    0_
$w MED00001940 $t Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie $x 1435-702X $g Roč. 251, č. 1 (2013), s. 341-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22588290 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130703 $b ABA008
991    __
$a 20130710092023 $b ABA008
999    __
$a ok $b bmc $g 988112 $s 822812
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 251 $c 1 $d 341-8 $i 1435-702X $m Graefe's archive for clinical and experimental ophthalmology $n Graefes Arch Clin Exp Ophthalmol $x MED00001940
LZP    __
$a Pubmed-20130703

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace