-
Je něco špatně v tomto záznamu ?
Viscoelasticity of biological materials - measurement and practical impact on biomedicine
M. Kucharová, S. Doubal, P. Klemera, P. Rejchrt, M. Navrátil
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- aorta thoracica fyziologie MeSH
- biologické modely MeSH
- dospělí MeSH
- fyziologie kůže * MeSH
- kosti a kostní tkáň fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mechanický stres MeSH
- pružnost MeSH
- reologie MeSH
- senioři MeSH
- Sus scrofa MeSH
- tlak MeSH
- točivý moment MeSH
- viskozita MeSH
- zvířata MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Mechanical behavior of biological structures under dynamic loading generally depends on elastic as well as viscous properties of biological materials. The significance of "viscous" parameters in real situations remains to be elucidated. Behavior of rheological models consisting of a combination of inertial body and two Voigt's bodies were described mathematically with respect to inverse problem solution, and behavior in impulse and harmonic loadings was analyzed. Samples of walls of porcine and human aorta thoracica in transverse direction and samples of human bone (caput femoris, substantia compacta) were measured. Deformation responses of human skin in vivo were also measured. Values of elastic moduli of porcine aorta walls were in the interval from 10(2)kPa to 10(3) kPa, values of viscous coefficients were in the interval from 10(2) Pa.s to 10(3) Pa.s. The value of shear stress moduli of human caput femoris, substantia compacta range from 52.7 to 161.1 MPa, and viscous coefficients were in the interval from 27.3 to 98.9 kPa.s. The role of viscous coefficients is significant for relatively high loading frequencies - in our materials above 8 Hz in aorta walls and 5 Hz for bones. In bones, the viscosity reduced maximum deformation corresponding to short rectangular stress.
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13034080
- 003
- CZ-PrNML
- 005
- 20161013081822.0
- 007
- ta
- 008
- 131021s2007 xr da f 000 0|eng||
- 009
- AR
- 035 __
- $a (PubMed)17552897
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Kuchařová, Monika $u Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic $7 jx20091105014
- 245 10
- $a Viscoelasticity of biological materials - measurement and practical impact on biomedicine / $c M. Kucharová, S. Doubal, P. Klemera, P. Rejchrt, M. Navrátil
- 520 9_
- $a Mechanical behavior of biological structures under dynamic loading generally depends on elastic as well as viscous properties of biological materials. The significance of "viscous" parameters in real situations remains to be elucidated. Behavior of rheological models consisting of a combination of inertial body and two Voigt's bodies were described mathematically with respect to inverse problem solution, and behavior in impulse and harmonic loadings was analyzed. Samples of walls of porcine and human aorta thoracica in transverse direction and samples of human bone (caput femoris, substantia compacta) were measured. Deformation responses of human skin in vivo were also measured. Values of elastic moduli of porcine aorta walls were in the interval from 10(2)kPa to 10(3) kPa, values of viscous coefficients were in the interval from 10(2) Pa.s to 10(3) Pa.s. The value of shear stress moduli of human caput femoris, substantia compacta range from 52.7 to 161.1 MPa, and viscous coefficients were in the interval from 27.3 to 98.9 kPa.s. The role of viscous coefficients is significant for relatively high loading frequencies - in our materials above 8 Hz in aorta walls and 5 Hz for bones. In bones, the viscosity reduced maximum deformation corresponding to short rectangular stress.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a aorta thoracica $x fyziologie $7 D001013
- 650 _2
- $a kosti a kostní tkáň $x fyziologie $7 D001842
- 650 _2
- $a pružnost $7 D004548
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a biologické modely $7 D008954
- 650 _2
- $a tlak $7 D011312
- 650 _2
- $a reologie $7 D012212
- 650 12
- $a fyziologie kůže $7 D012879
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a Sus scrofa $7 D034421
- 650 _2
- $a točivý moment $7 D019415
- 650 _2
- $a viskozita $7 D014783
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Ďoubal, Stanislav, $u Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic $d 1946- $7 jn19981002703
- 700 1_
- $a Klemera, Petr, $u Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic $d 1943-2021 $7 jk01060394
- 700 1_
- $a Rejchrt, Petr $u Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic $7 jx20091105016
- 700 1_
- $a Navrátil, Martin, $u Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic $d 1974- $7 xx0074086
- 773 0_
- $w MED00003824 $t Physiological research $x 0862-8408 $g Roč. 56, Suppl 1 (2007), s. S33-S37
- 773 0_
- $t Biophysics in medical research $x 0862-8408 $g Roč. 56, Suppl 1 (2007), s. S33-S37 $w MED00163483
- 856 41
- $u http://www.biomed.cas.cz/physiolres/pdf/56%20Suppl%201/56_S33.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 4 $z 0
- 990 __
- $a 20131021 $b ABA008
- 991 __
- $a 20161013082219 $b ABA008
- 999 __
- $a OK $b bmc $g 999630 $s 832550
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2007 $b 56 $c Suppl 1 $d S33-S37 $i 0862-8408 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- BMC __
- $a 2007 $b 56 $c Suppl 1 $d S33-S37 $i 0862-8408 $m Biophysics in medical research $x MED00163483
- LZP __
- $b NLK111 $a Pubmed-20131021