Something wrong with this record ?
Noninvasive assessment of local myocardium repolarization changes using high resolution surface ECG mapping
M. Tysler, P. Kneppo, M. Turzová, J. Svehlíková, S. Karas, E. Hebláková, K. Hána, S. Filipová
Language English Country Czech Republic
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Directory of Open Access Journals
from 1991
Free Medical Journals
from 1998
ProQuest Central
from 2005-01-01
Medline Complete (EBSCOhost)
from 2006-01-01
Nursing & Allied Health Database (ProQuest)
from 2005-01-01
Health & Medicine (ProQuest)
from 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
from 1998
- MeSH
- Action Potentials MeSH
- Angioplasty, Balloon, Coronary * MeSH
- Time Factors MeSH
- Myocardial Infarction pathology physiopathology therapy MeSH
- Middle Aged MeSH
- Humans MeSH
- Body Surface Potential Mapping methods MeSH
- Models, Cardiovascular MeSH
- Myocardium pathology MeSH
- Computer Simulation MeSH
- Signal Processing, Computer-Assisted MeSH
- Heart Conduction System physiopathology MeSH
- Reproducibility of Results MeSH
- Aged MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
A method using body surface potential maps for assessment of myocardium lesions with changed repolarization is presented and suitable mapping system is introduced. Differences between normal and altered QRST integral maps together with torso volume conductor model were used to determine the equivalent dipole representing the lesion. Performance of the method was studied on simulated data. Changed repolarization was modeled by shortening of myocyte action potentials in regions typical for stenosis of the main coronary arteries. The equivalent dipole estimated the positions of small lesions with a mean error of 9+/-4 mm (17+/-14 mm for larger transmural lesions). The subepicardial or subendocardial character of the lesions was reflected in the dipole orientation. Tests of the method on patients after myocardial infarction that underwent coronary intervention on a single coronary vessel showed that in 7 of 8 successfully treated patients the dipole position matched well with the treated vessel. A small dipole moment in another patient indicated unsuccessful treatment. The method was implemented in a new 128-channel mapping system. Its active electrodes, battery powered measuring unit and optical computer interface help to minimize noise in ECG and guarantee patient's safety. The results suggest that the method and mapping system offer useful tools for noninvasive identification of local repolarization changes in the myocardium.
Czech Technical University Faculty of Biomedical Engineering Kladno Czech Republic
Institute of Measurement Science Slovak Academy of Sciences Bratislava Slovakia
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13034093
- 003
- CZ-PrNML
- 005
- 20171205160708.0
- 007
- ta
- 008
- 131021s2007 xr ad f 000 0|eng||
- 009
- AR
- 035 __
- $a (PubMed)17552884
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Tyšler, Milan, $u Czech Technical University, Faculty of Biomedical Engineering, Kladno, Czech Republic; Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia $d 1951- $7 xx0301861
- 245 10
- $a Noninvasive assessment of local myocardium repolarization changes using high resolution surface ECG mapping / $c M. Tysler, P. Kneppo, M. Turzová, J. Svehlíková, S. Karas, E. Hebláková, K. Hána, S. Filipová
- 520 9_
- $a A method using body surface potential maps for assessment of myocardium lesions with changed repolarization is presented and suitable mapping system is introduced. Differences between normal and altered QRST integral maps together with torso volume conductor model were used to determine the equivalent dipole representing the lesion. Performance of the method was studied on simulated data. Changed repolarization was modeled by shortening of myocyte action potentials in regions typical for stenosis of the main coronary arteries. The equivalent dipole estimated the positions of small lesions with a mean error of 9+/-4 mm (17+/-14 mm for larger transmural lesions). The subepicardial or subendocardial character of the lesions was reflected in the dipole orientation. Tests of the method on patients after myocardial infarction that underwent coronary intervention on a single coronary vessel showed that in 7 of 8 successfully treated patients the dipole position matched well with the treated vessel. A small dipole moment in another patient indicated unsuccessful treatment. The method was implemented in a new 128-channel mapping system. Its active electrodes, battery powered measuring unit and optical computer interface help to minimize noise in ECG and guarantee patient's safety. The results suggest that the method and mapping system offer useful tools for noninvasive identification of local repolarization changes in the myocardium.
- 650 _2
- $a akční potenciály $7 D000200
- 650 _2
- $a senioři $7 D000368
- 650 12
- $a balónková koronární angioplastika $7 D015906
- 650 _2
- $a mapování potenciálů tělesného povrchu $x metody $7 D018780
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a převodní systém srdeční $x patofyziologie $7 D006329
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a modely kardiovaskulární $7 D008955
- 650 _2
- $a infarkt myokardu $x patologie $x patofyziologie $x terapie $7 D009203
- 650 _2
- $a myokard $x patologie $7 D009206
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a počítačové zpracování signálu $7 D012815
- 650 _2
- $a časové faktory $7 D013997
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Kneppo, Peter, $d 1940- $7 xx0122182 $u Czech Technical University, Faculty of Biomedical Engineering, Kladno, Czech Republic
- 700 1_
- $a Turzová, M. $u Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia $7 _AN051152
- 700 1_
- $a Švehlíková, Jana $u Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia $7 xx0256264
- 700 1_
- $a Karas, Slavomír $u Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia $7 xx0107492
- 700 1_
- $a Nagyová, Eva $u Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia $7 xx0107497
- 700 1_
- $a Hána, Karel, $u Czech Technical University, Faculty of Biomedical Engineering, Kladno, Czech Republic $d 1970- $7 ntka172706
- 700 1_
- $a Filipová, Slavomíra $u Slovak Healthcare University, Bratislava, Slovakia $7 xx0074547
- 773 0_
- $w MED00003824 $t Physiological research $x 0862-8408 $g Roč. 56, Suppl 1 (2007), s. S133-S141
- 773 0_
- $t Biophysics in medical research $x 0862-8408 $g Roč. 56, Suppl 1 (2007), s. S133-S141 $w MED00163483
- 856 41
- $u http://www.biomed.cas.cz/physiolres/pdf/56%20Suppl%201/56_S133.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 4 $z 0
- 990 __
- $a 20131021 $b ABA008
- 991 __
- $a 20171205160845 $b ABA008
- 999 __
- $a OK $b bmc $g 999643 $s 832563
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2007 $b 56 $c Suppl 1 $d S133-S141 $i 0862-8408 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- BMC __
- $a 2007 $b 56 $c Suppl 1 $d S133-S141 $i 0862-8408 $m Biophysics in medical research $x MED00163483
- LZP __
- $b NLK111 $a Pubmed-20131021