-
Something wrong with this record ?
Utilization of cone beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup
P. Paluska, J. Hanus, J. Sefrova, L. Rouskova, J. Grepl, J. Jansa, L. Kasaova, M. Hodek, M. Zouhar, M. Vosmik, J. Petera,
Language English Country United States
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Directory of Open Access Journals
from 2000
Free Medical Journals
from 2000
Open Journal Systems (OJS)
from 2004
PubMed Central
from 2000
Europe PubMed Central
from 2000
ProQuest Central
from 2000-03-01
Health & Medicine (ProQuest)
from 2000-03-01
Wiley-Blackwell Open Access Titles
from 2000
- MeSH
- Adenocarcinoma radiotherapy MeSH
- Radiotherapy Dosage MeSH
- Middle Aged MeSH
- Humans MeSH
- Prostatic Neoplasms radiotherapy MeSH
- Radiotherapy Planning, Computer-Assisted MeSH
- Cone-Beam Computed Tomography utilization MeSH
- Radiotherapy, Image-Guided * MeSH
- Aged MeSH
- Neoplasm Staging MeSH
- Fiducial Markers * MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired once a week immediately after the alignment. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed 1 cm safety margin. Alternative plans assuming smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with initial ones. While the margin reduction in case of BL setup makes the prostate coverage significantly worse (p = 0.0003, McNemar's test), in case of FM setup with the reduced 7 mm margin, the prostate coverage is even better compared to BL setup with 10 mm margin (p = 0.049, Fisher's exact test). Moreover, partial volumes of organs at risk irradiated with a specific dose can be significantly lowered (p < 0.0001, unpaired t-test). Reducing of safety margin is not acceptable in case of BL setup, while the margin can be lowered from 10 mm to 7 mm in case of FM setup.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14040758
- 003
- CZ-PrNML
- 005
- 20140220095853.0
- 007
- ta
- 008
- 140107s2013 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1120/jacmp.v14i3.4203 $2 doi
- 035 __
- $a (PubMed)23652250
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Paluska, Petr
- 245 10
- $a Utilization of cone beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup / $c P. Paluska, J. Hanus, J. Sefrova, L. Rouskova, J. Grepl, J. Jansa, L. Kasaova, M. Hodek, M. Zouhar, M. Vosmik, J. Petera,
- 520 9_
- $a The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired once a week immediately after the alignment. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed 1 cm safety margin. Alternative plans assuming smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with initial ones. While the margin reduction in case of BL setup makes the prostate coverage significantly worse (p = 0.0003, McNemar's test), in case of FM setup with the reduced 7 mm margin, the prostate coverage is even better compared to BL setup with 10 mm margin (p = 0.049, Fisher's exact test). Moreover, partial volumes of organs at risk irradiated with a specific dose can be significantly lowered (p < 0.0001, unpaired t-test). Reducing of safety margin is not acceptable in case of BL setup, while the margin can be lowered from 10 mm to 7 mm in case of FM setup.
- 650 _2
- $a adenokarcinom $x radioterapie $7 D000230
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a počítačová tomografie s kuželovým svazkem $x využití $7 D054893
- 650 12
- $a zaměřovací značky pro radioterapii $7 D057918
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a staging nádorů $7 D009367
- 650 _2
- $a nádory prostaty $x radioterapie $7 D011471
- 650 _2
- $a celková dávka radioterapie $7 D011879
- 650 _2
- $a plánování radioterapie pomocí počítače $7 D011880
- 650 12
- $a radioterapie řízená obrazem $7 D061089
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Hanus, Josef $u -
- 700 1_
- $a Sefrova, Jana $u -
- 700 1_
- $a Rouskova, Lucie $u -
- 700 1_
- $a Grepl, Jakub $u -
- 700 1_
- $a Jansa, Jan $u -
- 700 1_
- $a Kasaova, Linda $u -
- 700 1_
- $a Hodek, Miroslav $u -
- 700 1_
- $a Zouhar, Milan $u -
- 700 1_
- $a Vosmik, Milan $u -
- 700 1_
- $a Petera, Jiri $u -
- 773 0_
- $w MED00182991 $t Journal of applied clinical medical physics / American College of Medical Physics $x 1526-9914 $g Roč. 14, č. 3 (2013), s. 4203
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23652250 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20140107 $b ABA008
- 991 __
- $a 20140220100701 $b ABA008
- 999 __
- $a ok $b bmc $g 1005154 $s 839270
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 14 $c 3 $d 4203 $i 1526-9914 $m Journal of applied clinical medical physics $n J Appl Clin Med Phys $x MED00182991
- LZP __
- $a Pubmed-20140107