Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility

M. Caresana, M. Helmecke, J. Kubancak, GP. Manessi, K. Ott, R. Scherpelz, M. Silari,

. 2014 ; 161 (1-4) : 67-72.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc15023614

This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10).

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15023614
003      
CZ-PrNML
005      
20150727122602.0
007      
ta
008      
150709s2014 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/nct312 $2 doi
035    __
$a (PubMed)24292486
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Caresana, Marco $u Department of Energy, Politecnico of Milan, Via Ponzio 34/3, Milan 20133, Italy marco.silari@cern.ch.
245    10
$a Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility / $c M. Caresana, M. Helmecke, J. Kubancak, GP. Manessi, K. Ott, R. Scherpelz, M. Silari,
520    9_
$a This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10).
650    _2
$a kalibrace $7 D002138
650    _2
$a vystavení vlivu životního prostředí $x analýza $7 D004781
650    _2
$a design vybavení $7 D004867
650    _2
$a Evropská unie $7 D005062
650    _2
$a neutrony $7 D009502
650    _2
$a protony $7 D011522
650    12
$a dávka záření $7 D011829
650    _2
$a monitorování radiace $x přístrojové vybavení $x metody $7 D011834
650    _2
$a radiační ochrana $x přístrojové vybavení $x metody $7 D011835
650    _2
$a synchrotrony $7 D017356
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Helmecke, Manuela $u Helmholtz-Zentrum Berlin, BESYY II, Berlin 12849, Germany.
700    1_
$a Kubancak, Jan $u Department of Radiation Dosimetry, Nuclear Physics Institute of the ACSR, Na Truhlářce 39/64, Prague 180 00, Czech Republic Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Břehová 7, Prague 115 19, Czech Republic.
700    1_
$a Manessi, Giacomo Paolo $u CERN, Geneva 23 CH-1211, Switzerland Department of Physics, University of Liverpool, Liverpool L69 7ZE, UK.
700    1_
$a Ott, Klaus $u Helmholtz-Zentrum Berlin, BESYY II, Berlin 12849, Germany.
700    1_
$a Scherpelz, Robert $u Pacific Northwest National Laboratory, Richland, WA 99352, USA.
700    1_
$a Silari, Marco $u CERN, Geneva 23 CH-1211, Switzerland marco.silari@cern.ch.
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 161, č. 1-4 (2014), s. 67-72
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24292486 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150709 $b ABA008
991    __
$a 20150727122643 $b ABA008
999    __
$a ok $b bmc $g 1083951 $s 906607
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 161 $c 1-4 $d 67-72 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20150709

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...