Detail
Článek
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Artroskopická stabilizace akutní akromioklavikulární luxace implantátem TighRope
[Arthroscopic stabilisation of acute acromioclavicular dislocation using the TighRope device]

L. Bajnar, R. Bartoš, P. Šedivý

. 2013 ; 80 (6) : 386-390.

Jazyk čeština Země Česko

Typ dokumentu anglický abstrakt, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc15030712

Digitální knihovna NLK
Zdroj

E-zdroje NLK Online

Free Medical Journals od 2006

Odkazy
PubMed 24750965

PURPOSE OF THE STUDY: To present the TightRope (Arthrex, Naples, FL) technique and its results in the arthroscopic stabilisation of acute acromioclavicular joint (ACJ) dislocation carried out at our department. MATERIAL AND METHODS: From July 2009 till December 2010, arthroscopic stabilisation of acute ACJ dislocation was performed in 22 patients. The group consisted of 18 men and four women with an average age of 37.4 years. The Rockwood type III to type V ACJ dislocations (III, 16; IV, 1; V, 5) were indicated for surgery. The average interval between injury and surgery was 5.4 days. In all cases, a second-generation TightRope implant was inserted by the EndoButton technique joining the distal end of the clavicle and the coracoid process. The results were evaluated using the UCLA Shoulder Scale at 6 months after surgery. RESULTS: All 22 patients returned to their pre-operative activities without any restriction of shoulder motion within 5 months of surgery. The average post-operative UCLA score was 31.2 points (range, 28 to 35). Radiographic evidence of the loss of full reduction, with no effect on the clinical outcome, was recorded in four patients (18%) during post-operative rehabilitation. Of these, one had Rockwood type III, two had type IV and one had type V dislocations. One patient suffered post-operative pull-out of the implant from the coracoid; three patients showed skin wound healing by second intention above the lateral clavicle, with one requiring surgical repair under local anaesthesia. There was no neurovascular complication, intra- or postoperative fracture of the coracoid process or lateral clavicle, or deep wound infection. DISCUSSION: Arthroscopic stabilisation of acute ACJ dislocation is a minimally invasive procedure providing the coracoclavicular ligament complex with dynamic stability. In comparison with open procedures, it is less painful post-operatively, allows the patients to return early to daily activities and has a better cosmetic effect. It eliminates the necessity of removing the osteosynthetic material, as is the case in commonly used techniques such as Bosworth's method, K-wiring, osteorrhaphy or hook plate insertion. The loss of full reduction in four patients, as observed on radiographs during their rehabilitation, was not accompanied by any clinical problems and is in agreement with the findings of other authors. In our group, it occurred in Rockwood grade IV and grade V dislocations. For these, there is a possibility of using two implants in order to increase stability and prevent the loss of full reduction but this involves a higher risk of coracoid fracture, extension of operative time and higher costs. However, a loss of reduction in some patients has also been reported by the authors who have used two implants. Therefore we prefer using a single TightRope implant, particularly in acute grade III ACJ dislocations requiring surgical treatment in patients engaged in repetitive overhead activities related to sports or occupation. CONCLUSIONS: Arthroscopic stabilisation of acute ACJ dislocations using a single TightRope implant is an elegant minimally invasive method with good results in indicated cases. It proves efficient particularly in Rockwood type III injuries in patients who have to do repetitive overhead activities. Acute type IV and type V ACJ dislocations treated by this technique show a loss of full reduction on radiographs more frequently, although no effect on the clinical outcome is evident.

Arthroscopic stabilisation of acute acromioclavicular dislocation using the TighRope device

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc15030712
003      
CZ-PrNML
005      
20151016071350.0
007      
ta
008      
150929s2013 xr a f 000 0|cze||
009      
AR
024    7_
$2 doi $a 10.55095/achot2013/065
035    __
$a (PubMed)24750965
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Bajnar, L. $u Ortopedicko-traumatologické oddělení, Klaudiánova nemocnice, Mladá Boleslav $7 _AN084602
245    10
$a Artroskopická stabilizace akutní akromioklavikulární luxace implantátem TighRope / $c L. Bajnar, R. Bartoš, P. Šedivý
246    31
$a Arthroscopic stabilisation of acute acromioclavicular dislocation using the TighRope device
504    __
$a Literatura
520    9_
$a PURPOSE OF THE STUDY: To present the TightRope (Arthrex, Naples, FL) technique and its results in the arthroscopic stabilisation of acute acromioclavicular joint (ACJ) dislocation carried out at our department. MATERIAL AND METHODS: From July 2009 till December 2010, arthroscopic stabilisation of acute ACJ dislocation was performed in 22 patients. The group consisted of 18 men and four women with an average age of 37.4 years. The Rockwood type III to type V ACJ dislocations (III, 16; IV, 1; V, 5) were indicated for surgery. The average interval between injury and surgery was 5.4 days. In all cases, a second-generation TightRope implant was inserted by the EndoButton technique joining the distal end of the clavicle and the coracoid process. The results were evaluated using the UCLA Shoulder Scale at 6 months after surgery. RESULTS: All 22 patients returned to their pre-operative activities without any restriction of shoulder motion within 5 months of surgery. The average post-operative UCLA score was 31.2 points (range, 28 to 35). Radiographic evidence of the loss of full reduction, with no effect on the clinical outcome, was recorded in four patients (18%) during post-operative rehabilitation. Of these, one had Rockwood type III, two had type IV and one had type V dislocations. One patient suffered post-operative pull-out of the implant from the coracoid; three patients showed skin wound healing by second intention above the lateral clavicle, with one requiring surgical repair under local anaesthesia. There was no neurovascular complication, intra- or postoperative fracture of the coracoid process or lateral clavicle, or deep wound infection. DISCUSSION: Arthroscopic stabilisation of acute ACJ dislocation is a minimally invasive procedure providing the coracoclavicular ligament complex with dynamic stability. In comparison with open procedures, it is less painful post-operatively, allows the patients to return early to daily activities and has a better cosmetic effect. It eliminates the necessity of removing the osteosynthetic material, as is the case in commonly used techniques such as Bosworth's method, K-wiring, osteorrhaphy or hook plate insertion. The loss of full reduction in four patients, as observed on radiographs during their rehabilitation, was not accompanied by any clinical problems and is in agreement with the findings of other authors. In our group, it occurred in Rockwood grade IV and grade V dislocations. For these, there is a possibility of using two implants in order to increase stability and prevent the loss of full reduction but this involves a higher risk of coracoid fracture, extension of operative time and higher costs. However, a loss of reduction in some patients has also been reported by the authors who have used two implants. Therefore we prefer using a single TightRope implant, particularly in acute grade III ACJ dislocations requiring surgical treatment in patients engaged in repetitive overhead activities related to sports or occupation. CONCLUSIONS: Arthroscopic stabilisation of acute ACJ dislocations using a single TightRope implant is an elegant minimally invasive method with good results in indicated cases. It proves efficient particularly in Rockwood type III injuries in patients who have to do repetitive overhead activities. Acute type IV and type V ACJ dislocations treated by this technique show a loss of full reduction on radiographs more frequently, although no effect on the clinical outcome is evident.
650    _2
$a akromioklavikulární kloub $x zranění $x patofyziologie $x radiografie $7 D000173
650    _2
$a dospělí $7 D000328
650    12
$a artroskopie $x škodlivé účinky $x přístrojové vybavení $x metody $7 D001182
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a interní fixátory $7 D016268
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a pooperační komplikace $x diagnóza $7 D011183
650    _2
$a pooperační období $7 D011184
650    _2
$a selhání protézy $x etiologie $7 D011475
650    _2
$a retence protézy $x škodlivé účinky $x metody $7 D060489
650    _2
$a rozsah kloubních pohybů $7 D016059
650    _2
$a obnova funkce $7 D020127
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a luxace ramenního kloubu $x diagnóza $x patofyziologie $x chirurgie $7 D012783
650    _2
$a čas zasáhnout při rozvinutí nemoci $7 D061665
650    _2
$a výsledek terapie $7 D016896
655    _2
$a anglický abstrakt $7 D004740
655    _2
$a časopisecké články $7 D016428
700    1_
$a Bartoš, R. $u Ortopedicko-traumatologické oddělení, Klaudiánova nemocnice, Mladá Boleslav $7 _AN084603
700    1_
$a Šedivý, Pavel $7 xx0205023 $u Ortopedicko-traumatologické oddělení, Klaudiánova nemocnice, Mladá Boleslav
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 80, č. 6 (2013), s. 386-390
910    __
$a ABA008 $b A 8 $c 507 $y 4 $z 0
990    __
$a 20150929 $b ABA008
991    __
$a 20151015083027 $b ABA008
999    __
$a ok $b bmc $g 1094169 $s 913825
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 80 $c 6 $d 386-390 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$b NLK118 $a Pubmed-20150929

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...