A rare case of a fracture of the anatomical neck of the humerus associated with a posterior dislocation of the shoulder in a 43-year-old man is presented. It was managed by immediate surgery using locking plate osteosynthesis. The shoulder was immobilised for 5 weeks in a Gilchrist brace. The outcome was very good with a full range of motion and a stable shoulder at 1 year after injury, with no signs of avascular necrosis of the humeral head. The aetiology of this injury and possibilities of its treatment are discussed. Key words: shoulder dislocation, humeral fractures.
- MeSH
- dospělí MeSH
- fraktury humeru patologie patofyziologie chirurgie MeSH
- hlavice humeru patologie patofyziologie chirurgie MeSH
- kostní destičky MeSH
- lidé MeSH
- luxace ramenního kloubu patofyziologie chirurgie MeSH
- rozsah kloubních pohybů MeSH
- vnitřní fixace fraktury přístrojové vybavení MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
PURPOSE OF THE STUDY: Shoulder instability adversely affects the quality of life and restricts the functional capacity of the upper extremity involved. Today stabilisation surgery is almost always performed arthroscopically. The aim of this study was to present our experience with arthroscopic stabilisation of the shoulder and to identify risk factors responsible for its failure. MATERIAL AND METHODS: The group of 110 patients with recurrent anterior dislocation of the shoulder, who were treated between January 2007 and December 2010, consisted of 19 women and 91 men with an average age of 27 years (range, 14 to 56) at the time of surgery. Patients who had a concomitant tear of the rotator cuff or of the long head tendon of the biceps were excluded from the study. The minimum follow-up period was 2 years. The patients were evaluated for signs of clinical instability. Function was evaluated using WOSI, Constant-Murley and Rowe-Zarins. Statistical methods were used to assess factors leading to failed arthroscopic stabilisation. RESULTS: At final follow-up, 17 patients (17 shoulders, 15.3%) had re-dislocation or subluxation of the joint treated. Age over 20 years reduced the probability of re-dislocation (odds ratio, OR=0.87; p=0.021) while the finding of an engaging Hill-Sachs lesion increased the risk of re-dislocation (OR=5.53; p=0.0028). The presence of a bony Bankart lesion had only a marginal effect on the probability of re-dislocation (p=0.0512). In stable shoulders the average pre-operative values improved to the final follow-up values as follows: WOSI index, 53.65 ± 5.6 to 94.8 ± 5.2 (p<0.0001); Constant-Murley score, 78.9 ± 6.1 to 95.6 ± 4.4 (p<0.0001); and Rowe-Zarins score, 53.3 ± 6.7 to 92.9 ± 7.8 (p<0.0001). No peri-operative complication was recorded. DISCUSSION: Our study confirmed the role of 3D CT examination before arthroscopic stabilisation of the shoulder joint. The exact identification of bone injury and its extent is of prognostic importance. At the same time special attention should be paid to surgical and post-operative tactics in patients operated on before their 20 years of age. On the other hand, no risks were found to be associated with gender, sports activities, the number of previous dislocations, types of anchors, suture material or knot tying. CONCLUSIONS: Arthroscopic stabilisation of the shoulder significantly relieves pain and improves shoulder function in 85% of the patients with anterior shoulder dislocation. The risk that this stabilisation surgery will fail increases with lower age of the patient and the presence of an engaging Hill-Sachs lesion.
- MeSH
- artroskopie * škodlivé účinky metody MeSH
- dospělí MeSH
- hodnocení výsledků zdravotní péče MeSH
- kvalita života * MeSH
- lidé MeSH
- luxace ramenního kloubu * diagnóza etiologie patofyziologie psychologie chirurgie MeSH
- následné studie MeSH
- nestabilita kloubu * diagnóza etiologie patofyziologie psychologie chirurgie MeSH
- obnova funkce MeSH
- ramenní kloub * zranění chirurgie MeSH
- recidiva MeSH
- reoperace metody MeSH
- rizikové faktory MeSH
- rozsah kloubních pohybů MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
PURPOSE OF THE STUDY: To present the TightRope (Arthrex, Naples, FL) technique and its results in the arthroscopic stabilisation of acute acromioclavicular joint (ACJ) dislocation carried out at our department. MATERIAL AND METHODS: From July 2009 till December 2010, arthroscopic stabilisation of acute ACJ dislocation was performed in 22 patients. The group consisted of 18 men and four women with an average age of 37.4 years. The Rockwood type III to type V ACJ dislocations (III, 16; IV, 1; V, 5) were indicated for surgery. The average interval between injury and surgery was 5.4 days. In all cases, a second-generation TightRope implant was inserted by the EndoButton technique joining the distal end of the clavicle and the coracoid process. The results were evaluated using the UCLA Shoulder Scale at 6 months after surgery. RESULTS: All 22 patients returned to their pre-operative activities without any restriction of shoulder motion within 5 months of surgery. The average post-operative UCLA score was 31.2 points (range, 28 to 35). Radiographic evidence of the loss of full reduction, with no effect on the clinical outcome, was recorded in four patients (18%) during post-operative rehabilitation. Of these, one had Rockwood type III, two had type IV and one had type V dislocations. One patient suffered post-operative pull-out of the implant from the coracoid; three patients showed skin wound healing by second intention above the lateral clavicle, with one requiring surgical repair under local anaesthesia. There was no neurovascular complication, intra- or postoperative fracture of the coracoid process or lateral clavicle, or deep wound infection. DISCUSSION: Arthroscopic stabilisation of acute ACJ dislocation is a minimally invasive procedure providing the coracoclavicular ligament complex with dynamic stability. In comparison with open procedures, it is less painful post-operatively, allows the patients to return early to daily activities and has a better cosmetic effect. It eliminates the necessity of removing the osteosynthetic material, as is the case in commonly used techniques such as Bosworth's method, K-wiring, osteorrhaphy or hook plate insertion. The loss of full reduction in four patients, as observed on radiographs during their rehabilitation, was not accompanied by any clinical problems and is in agreement with the findings of other authors. In our group, it occurred in Rockwood grade IV and grade V dislocations. For these, there is a possibility of using two implants in order to increase stability and prevent the loss of full reduction but this involves a higher risk of coracoid fracture, extension of operative time and higher costs. However, a loss of reduction in some patients has also been reported by the authors who have used two implants. Therefore we prefer using a single TightRope implant, particularly in acute grade III ACJ dislocations requiring surgical treatment in patients engaged in repetitive overhead activities related to sports or occupation. CONCLUSIONS: Arthroscopic stabilisation of acute ACJ dislocations using a single TightRope implant is an elegant minimally invasive method with good results in indicated cases. It proves efficient particularly in Rockwood type III injuries in patients who have to do repetitive overhead activities. Acute type IV and type V ACJ dislocations treated by this technique show a loss of full reduction on radiographs more frequently, although no effect on the clinical outcome is evident.
- MeSH
- akromioklavikulární kloub zranění patofyziologie radiografie MeSH
- artroskopie * škodlivé účinky přístrojové vybavení metody MeSH
- čas zasáhnout při rozvinutí nemoci MeSH
- dospělí MeSH
- interní fixátory MeSH
- lidé MeSH
- luxace ramenního kloubu diagnóza patofyziologie chirurgie MeSH
- obnova funkce MeSH
- pooperační komplikace diagnóza MeSH
- pooperační období MeSH
- retence protézy škodlivé účinky metody MeSH
- retrospektivní studie MeSH
- rozsah kloubních pohybů MeSH
- selhání protézy etiologie MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH