• Je něco špatně v tomto záznamu ?

Quantitative phase imaging through scattering media by means of coherence-controlled holographic microscope

V. Kollarova, J. Collakova, Z. Dostal, P. Vesely, R. Chmelik,

. 2015 ; 20 (11) : 111206.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16020442

A coherence-controlled holographic microscope (CCHM) enables quantitative phase imaging with coherent as well as incoherent illumination. The low spatially coherent light induces a coherence gating effect, which makes observation of samples possible also through scattering media. The paper describes theoretically and simulates numerically imaging of a two-dimensional object through a static scattering layer by means of CCHM, with the main focus on the quantitative phase imaging quality. The authors have investigated both strongly and weakly scattering media characterized by different amounts of ballistic and diffuse light. It is demonstrated that the phase information can be revealed also for the case of the static, strongly scattering layer. The dependence of the quality of imaging process on the spatial light coherence is demonstrated. The theoretical calculations and numerical simulations are supported by experimental data gained with a model phase object, as well as living carcinoma cells treated in an optically turbid emulsion.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16020442
003      
CZ-PrNML
005      
20160729094022.0
007      
ta
008      
160722s2015 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1117/1.JBO.20.11.111206 $2 doi
024    7_
$a 10.1117/1.JBO.20.11.111206 $2 doi
035    __
$a (PubMed)26244853
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Kollarova, Vera $u Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech Republic.
245    10
$a Quantitative phase imaging through scattering media by means of coherence-controlled holographic microscope / $c V. Kollarova, J. Collakova, Z. Dostal, P. Vesely, R. Chmelik,
520    9_
$a A coherence-controlled holographic microscope (CCHM) enables quantitative phase imaging with coherent as well as incoherent illumination. The low spatially coherent light induces a coherence gating effect, which makes observation of samples possible also through scattering media. The paper describes theoretically and simulates numerically imaging of a two-dimensional object through a static scattering layer by means of CCHM, with the main focus on the quantitative phase imaging quality. The authors have investigated both strongly and weakly scattering media characterized by different amounts of ballistic and diffuse light. It is demonstrated that the phase information can be revealed also for the case of the static, strongly scattering layer. The dependence of the quality of imaging process on the spatial light coherence is demonstrated. The theoretical calculations and numerical simulations are supported by experimental data gained with a model phase object, as well as living carcinoma cells treated in an optically turbid emulsion.
650    _2
$a algoritmy $7 D000465
650    _2
$a nádorové buněčné linie $7 D045744
650    _2
$a počítačová simulace $7 D003198
650    _2
$a holografie $x metody $7 D006696
650    _2
$a lidé $7 D006801
650    _2
$a počítačové zpracování obrazu $x metody $7 D007091
650    _2
$a světlo $7 D008027
650    _2
$a mikroskopie $x metody $7 D008853
650    _2
$a radiační rozptyl $7 D012542
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Collakova, Jana $u Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech RepublicbBrno University of Technology, Institute of Physical Engineering, Faculty of Mechanical Engineering, Technicka 2896/2, Brno 616.
700    1_
$a Dostal, Zbynek $u Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech RepublicbBrno University of Technology, Institute of Physical Engineering, Faculty of Mechanical Engineering, Technicka 2896/2, Brno 616.
700    1_
$a Vesely, Pavel $u Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech Republic.
700    1_
$a Chmelik, Radim $u Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech RepublicbBrno University of Technology, Institute of Physical Engineering, Faculty of Mechanical Engineering, Technicka 2896/2, Brno 616.
773    0_
$w MED00180283 $t Journal of biomedical optics $x 1560-2281 $g Roč. 20, č. 11 (2015), s. 111206
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26244853 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160722 $b ABA008
991    __
$a 20160729094246 $b ABA008
999    __
$a ok $b bmc $g 1155112 $s 944970
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 20 $c 11 $d 111206 $i 1560-2281 $m Journal of biomedical optics $n J Biomed Opt $x MED00180283
LZP    __
$a Pubmed-20160722

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...