Something wrong with this record ?
The portable device for continual measurement of radon progenies on filter using the detector Timepix
B. Bulanek, J. Hulka, K. Jilek, I. Stekl,
Language English Country England, Great Britain
Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't
PubMed
25990115
DOI
10.1093/rpd/ncv343
Knihovny.cz E-resources
- MeSH
- Aerosols MeSH
- Alpha Particles MeSH
- Analog-Digital Conversion MeSH
- Beta Particles MeSH
- Radon Daughters analysis MeSH
- Equipment Design MeSH
- Silicon MeSH
- Radiation Monitoring instrumentation methods MeSH
- Signal Processing, Computer-Assisted MeSH
- Air Pollutants, Radioactive analysis MeSH
- Radon analysis MeSH
- Ultrafiltration MeSH
- Air Pollution, Indoor analysis MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
In this article, a portable device was presented for continual measuring of equilibrium equivalent concentration (EEC) of (222)Rn based on the Timepix detector with 300-µm-thick active layer. In order to have a portable device, a filtration head was developed for collecting short-lived radon progenies attached on aerosols. The short-lived progenies are estimated from analysing alphas from decay of (218,214)Po from Millipore filter after termination of filtration. Comparison with beta measurement was done as well. The dependence of EEC on an air flow and filtration time was studied. The low-level detection limit for EEC was estimated from the last 10 min of 3-h decay measurement and was found in the range of 40-70 Bq m(-3). EEC was measured in National Radiation Protection Institute radon chamber, and results were compared with the commercial detector Fritra4.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16020775
- 003
- CZ-PrNML
- 005
- 20160722121411.0
- 007
- ta
- 008
- 160722s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/rpd/ncv343 $2 doi
- 024 7_
- $a 10.1093/rpd/ncv343 $2 doi
- 035 __
- $a (PubMed)25990115
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Bulanek, Boris $u National Radiation Protection Institute, Bartoskova 28, Prague 140 00, Czech Republic boris.bulanek@suro.cz.
- 245 14
- $a The portable device for continual measurement of radon progenies on filter using the detector Timepix / $c B. Bulanek, J. Hulka, K. Jilek, I. Stekl,
- 520 9_
- $a In this article, a portable device was presented for continual measuring of equilibrium equivalent concentration (EEC) of (222)Rn based on the Timepix detector with 300-µm-thick active layer. In order to have a portable device, a filtration head was developed for collecting short-lived radon progenies attached on aerosols. The short-lived progenies are estimated from analysing alphas from decay of (218,214)Po from Millipore filter after termination of filtration. Comparison with beta measurement was done as well. The dependence of EEC on an air flow and filtration time was studied. The low-level detection limit for EEC was estimated from the last 10 min of 3-h decay measurement and was found in the range of 40-70 Bq m(-3). EEC was measured in National Radiation Protection Institute radon chamber, and results were compared with the commercial detector Fritra4.
- 650 _2
- $a aerosoly $7 D000336
- 650 _2
- $a radioaktivní látky znečišťující vzduch $x analýza $7 D000396
- 650 _2
- $a znečištění vzduchu ve vnitřním prostředí $x analýza $7 D016902
- 650 _2
- $a alfa částice $7 D000512
- 650 _2
- $a analogově digitální konverze $7 D000703
- 650 _2
- $a beta částice $7 D001610
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a monitorování radiace $x přístrojové vybavení $x metody $7 D011834
- 650 _2
- $a radon $x analýza $7 D011886
- 650 _2
- $a dceřiné produkty radonu $x analýza $7 D017687
- 650 _2
- $a počítačové zpracování signálu $7 D012815
- 650 _2
- $a křemík $7 D012825
- 650 _2
- $a ultrafiltrace $7 D014462
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Hulka, Jiri $u National Radiation Protection Institute, Bartoskova 28, Prague 140 00, Czech Republic.
- 700 1_
- $a Jilek, Karel $u National Radiation Protection Institute, Bartoskova 28, Prague 140 00, Czech Republic.
- 700 1_
- $a Stekl, Ivan $u Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, Prague 128 00, Czech Republic.
- 773 0_
- $w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 164, č. 4 (2015), s. 493-6
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25990115 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160722 $b ABA008
- 991 __
- $a 20160722121625 $b ABA008
- 999 __
- $a ok $b bmc $g 1155445 $s 945303
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 164 $c 4 $d 493-6 $e 20150519 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
- LZP __
- $a Pubmed-20160722