-
Je něco špatně v tomto záznamu ?
Newly developed Ti-Nb-Zr-Ta-Si-Fe biomedical beta titanium alloys with increased strength and enhanced biocompatibility
I. Kopova, J. Stráský, P. Harcuba, M. Landa, M. Janeček, L. Bačákova,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- biokompatibilní materiály chemie farmakologie MeSH
- niob chemie MeSH
- osteogeneze účinky léků MeSH
- oxid křemičitý chemie MeSH
- titan chemie MeSH
- železo chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Beta titanium alloys are promising materials for load-bearing orthopaedic implants due to their excellent corrosion resistance and biocompatibility, low elastic modulus and moderate strength. Metastable beta-Ti alloys can be hardened via precipitation of the alpha phase; however, this has an adverse effect on the elastic modulus. Small amounts of Fe (0-2 wt.%) and Si (0-1 wt.%) were added to Ti-35Nb-7Zr-6Ta (TNZT) biocompatible alloy to increase its strength in beta solution treated condition. Fe and Si additions were shown to cause a significant increase in tensile strength and also in the elastic modulus (from 65 GPa to 85 GPa). However, the elastic modulus of TNZT alloy with Fe and Si additions is still much lower than that of widely used Ti-6Al-4V alloy (115 GPa), and thus closer to that of the bone (10-30 GPa). Si decreases the elongation to failure, whereas Fe increases the uniform elongation thanks to increased work hardening. Primary human osteoblasts cultivated for 21 days on TNZT with 0.5Si+2Fe (wt.%) reached a significantly higher cell population density and significantly higher collagen I production than cells cultured on the standard Ti-6Al-4V alloy. In conclusion, the Ti-35Nb-7Zr-6Ta-2Fe-0.5Si alloy proves to be the best combination of elastic modulus, strength and also biological properties, which makes it a viable candidate for use in load-bearing implants.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16027785
- 003
- CZ-PrNML
- 005
- 20161025120937.0
- 007
- ta
- 008
- 161005s2016 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.msec.2015.11.043 $2 doi
- 024 7_
- $a 10.1016/j.msec.2015.11.043 $2 doi
- 035 __
- $a (PubMed)26706526
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Kopova, Ivana $u Department of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 14220 Prague 4, , Czech Republic. Electronic address: ivana.kopova@biomed.cas.cz.
- 245 10
- $a Newly developed Ti-Nb-Zr-Ta-Si-Fe biomedical beta titanium alloys with increased strength and enhanced biocompatibility / $c I. Kopova, J. Stráský, P. Harcuba, M. Landa, M. Janeček, L. Bačákova,
- 520 9_
- $a Beta titanium alloys are promising materials for load-bearing orthopaedic implants due to their excellent corrosion resistance and biocompatibility, low elastic modulus and moderate strength. Metastable beta-Ti alloys can be hardened via precipitation of the alpha phase; however, this has an adverse effect on the elastic modulus. Small amounts of Fe (0-2 wt.%) and Si (0-1 wt.%) were added to Ti-35Nb-7Zr-6Ta (TNZT) biocompatible alloy to increase its strength in beta solution treated condition. Fe and Si additions were shown to cause a significant increase in tensile strength and also in the elastic modulus (from 65 GPa to 85 GPa). However, the elastic modulus of TNZT alloy with Fe and Si additions is still much lower than that of widely used Ti-6Al-4V alloy (115 GPa), and thus closer to that of the bone (10-30 GPa). Si decreases the elongation to failure, whereas Fe increases the uniform elongation thanks to increased work hardening. Primary human osteoblasts cultivated for 21 days on TNZT with 0.5Si+2Fe (wt.%) reached a significantly higher cell population density and significantly higher collagen I production than cells cultured on the standard Ti-6Al-4V alloy. In conclusion, the Ti-35Nb-7Zr-6Ta-2Fe-0.5Si alloy proves to be the best combination of elastic modulus, strength and also biological properties, which makes it a viable candidate for use in load-bearing implants.
- 650 _2
- $a biokompatibilní materiály $x chemie $x farmakologie $7 D001672
- 650 _2
- $a železo $x chemie $7 D007501
- 650 _2
- $a niob $x chemie $7 D009556
- 650 _2
- $a osteogeneze $x účinky léků $7 D010012
- 650 _2
- $a oxid křemičitý $x chemie $7 D012822
- 650 _2
- $a titan $x chemie $7 D014025
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Stráský, Josef $u Department of Physics of Materials, Faculty of Mathematics and Physics, Charles University in Prague, Ke Karlovu 5, 121 16 Prague 2, Czech Republic.
- 700 1_
- $a Harcuba, Petr $u Department of Physics of Materials, Faculty of Mathematics and Physics, Charles University in Prague, Ke Karlovu 5, 121 16 Prague 2, Czech Republic.
- 700 1_
- $a Landa, Michal $u Institute of Thermomechanics, Academy of Sciences of the Czech Republic, Dolejskova 5, 182 00 Prague 8, Czech Republic.
- 700 1_
- $a Janeček, Miloš $u Department of Physics of Materials, Faculty of Mathematics and Physics, Charles University in Prague, Ke Karlovu 5, 121 16 Prague 2, Czech Republic.
- 700 1_
- $a Bačákova, Lucie $u Department of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 14220 Prague 4, , Czech Republic.
- 773 0_
- $w MED00184559 $t Materials science & engineering. C, Materials for biological applications $x 1873-0191 $g Roč. 60, č. - (2016), s. 230-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26706526 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20161005 $b ABA008
- 991 __
- $a 20161025121351 $b ABA008
- 999 __
- $a ok $b bmc $g 1166099 $s 952415
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 60 $c - $d 230-8 $e 20151117 $i 1873-0191 $m Materials science & engineering. C, Materials for biological applications $n Mater Sci Eng C Mater Biol Appl $x MED00184559
- LZP __
- $a Pubmed-20161005