Electrocardiographic predictors of coronary microvascular dysfunction in patients with non-obstructive coronary artery disease: Utility of a novel T wave analysis program

JD. Sara, A. Sugrue, V. Kremen, B. Qiang, Y. Sapir, ZI. Attia, MJ. Ackerman, PA. Friedman, A. Lerman, PA. Noseworthy,

. 2016 ; 203 (-) : 601-6. [pub] 20151101

Language English Country Netherlands

Document type Journal Article, Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't

BACKGROUND: Coronary microvascular dysfunction (CMD) is linked to adverse cardiovascular events. Definitive diagnosis of CMD requires invasive provocative testing during angiography. We developed and tested a novel computerized T wave analysis tool to identify electrocardiographic signatures of CMD. METHODS: 1552 patients underwent an invasive assessment of coronary microvascular function. Patients with interpretable pre-procedural ECGs were divided into 2 age and sex matched groups (n=261 in each group, 75% female): normal microvascular function, CFR>2.5 (CFR+), and abnormal microvascular function, CFR ≤ 2.5 (CFR-). ECGs were evaluated using a novel T wave program that quantified subtle changes in T wave morphology. RESULTS: T wave repolarization parameters were significantly different between patients with normal and abnormal microvascular function. The top 3 features in males comprised of T wave area in V6 (CFR+: 10091.4 mV(2) vs. CFR-: 8152.3 mV(2), p<0.05); T1 Y-center of gravity in lead II (CFR+: 17.8 mV vs. CFR-: 22.4, p<0.005) and T Peak-T End in lead II (CFR+: 97.6 msec vs. CFR-: 91.1 msec, p<0.05). These could identify the presence of an abnormal CFR with 74 ± 0.2% accuracy. In females, the top 3 features were T wave right slope lead V6 (CFR+: -2489.1 mV/msec vs. CFR-: -2352.3 mV/msec, p<0.005); Amplitude in V6 (CFR+: 190.4 mV vs. 172.7 mV, p=0.05) and Y-center of gravity in lead V1 (CFR+: 33.3 vs. CFR-: 40.0, p=0.001). These features could identify the presence of an abnormal CFR with 67 ± 0.3% accuracy. CONCLUSION: Our data demonstrates that a computer-based repolarization measurement tool may identify electrocardiographic signatures of CMD.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16027946
003      
CZ-PrNML
005      
20161024104830.0
007      
ta
008      
161005s2016 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ijcard.2015.10.228 $2 doi
024    7_
$a 10.1016/j.ijcard.2015.10.228 $2 doi
035    __
$a (PubMed)26580336
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Sara, Jaskanwal D $u Division of Cardiovascular Diseases, Mayo College of Medicine, Rochester, MN, USA.
245    10
$a Electrocardiographic predictors of coronary microvascular dysfunction in patients with non-obstructive coronary artery disease: Utility of a novel T wave analysis program / $c JD. Sara, A. Sugrue, V. Kremen, B. Qiang, Y. Sapir, ZI. Attia, MJ. Ackerman, PA. Friedman, A. Lerman, PA. Noseworthy,
520    9_
$a BACKGROUND: Coronary microvascular dysfunction (CMD) is linked to adverse cardiovascular events. Definitive diagnosis of CMD requires invasive provocative testing during angiography. We developed and tested a novel computerized T wave analysis tool to identify electrocardiographic signatures of CMD. METHODS: 1552 patients underwent an invasive assessment of coronary microvascular function. Patients with interpretable pre-procedural ECGs were divided into 2 age and sex matched groups (n=261 in each group, 75% female): normal microvascular function, CFR>2.5 (CFR+), and abnormal microvascular function, CFR ≤ 2.5 (CFR-). ECGs were evaluated using a novel T wave program that quantified subtle changes in T wave morphology. RESULTS: T wave repolarization parameters were significantly different between patients with normal and abnormal microvascular function. The top 3 features in males comprised of T wave area in V6 (CFR+: 10091.4 mV(2) vs. CFR-: 8152.3 mV(2), p<0.05); T1 Y-center of gravity in lead II (CFR+: 17.8 mV vs. CFR-: 22.4, p<0.005) and T Peak-T End in lead II (CFR+: 97.6 msec vs. CFR-: 91.1 msec, p<0.05). These could identify the presence of an abnormal CFR with 74 ± 0.2% accuracy. In females, the top 3 features were T wave right slope lead V6 (CFR+: -2489.1 mV/msec vs. CFR-: -2352.3 mV/msec, p<0.005); Amplitude in V6 (CFR+: 190.4 mV vs. 172.7 mV, p=0.05) and Y-center of gravity in lead V1 (CFR+: 33.3 vs. CFR-: 40.0, p=0.001). These features could identify the presence of an abnormal CFR with 67 ± 0.3% accuracy. CONCLUSION: Our data demonstrates that a computer-based repolarization measurement tool may identify electrocardiographic signatures of CMD.
650    _2
$a automatizované zpracování dat $x metody $7 D001330
650    _2
$a rychlost toku krve $7 D001783
650    _2
$a koronární angiografie $7 D017023
650    _2
$a nemoci koronárních tepen $x diagnóza $x patofyziologie $7 D003324
650    _2
$a koronární cirkulace $x fyziologie $7 D003326
650    _2
$a koronární cévy $x patofyziologie $7 D003331
650    _2
$a elektrokardiografie $x metody $7 D004562
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a následné studie $7 D005500
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a mikrocirkulace $x fyziologie $7 D008833
650    _2
$a lidé středního věku $7 D008875
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a stupeň závažnosti nemoci $7 D012720
650    12
$a software $7 D012984
650    _2
$a intervenční ultrasonografie $7 D018084
655    _2
$a časopisecké články $7 D016428
655    _2
$a Research Support, N.I.H., Extramural $7 D052061
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Sugrue, Alan $u Division of Internal Medicine, Mayo College of Medicine, Rochester, MN, USA.
700    1_
$a Kremen, Vaclav $u Division of Cardiovascular Diseases, Mayo College of Medicine, Rochester, MN, USA; Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University in Prague, Czech Republic.
700    1_
$a Qiang, Bo $u Division of Cardiovascular Diseases, Mayo College of Medicine, Rochester, MN, USA.
700    1_
$a Sapir, Yehu $u Electrical and Computer Engineering, Ben-Gurion University of the Negev, Beer Sheva, Israel.
700    1_
$a Attia, Zachi I $u Electrical and Computer Engineering, Ben-Gurion University of the Negev, Beer Sheva, Israel. $7 gn_A_00009865
700    1_
$a Ackerman, Michael J $u Division of Cardiovascular Diseases, Mayo College of Medicine, Rochester, MN, USA. $7 gn_A_00001006
700    1_
$a Friedman, Paul A $u Division of Cardiovascular Diseases, Mayo College of Medicine, Rochester, MN, USA.
700    1_
$a Lerman, Amir $u Division of Cardiovascular Diseases, Mayo College of Medicine, Rochester, MN, USA.
700    1_
$a Noseworthy, Peter A $u Division of Cardiovascular Diseases, Mayo College of Medicine, Rochester, MN, USA. Electronic address: noseworthy.peter@mayo.edu.
773    0_
$w MED00002299 $t International journal of cardiology $x 1874-1754 $g Roč. 203, č. - (2016), s. 601-6
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26580336 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20161005 $b ABA008
991    __
$a 20161024105242 $b ABA008
999    __
$a ok $b bmc $g 1166260 $s 952576
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 203 $c - $d 601-6 $e 20151101 $i 1874-1754 $m International journal of cardiology $n Int J Cardiol $x MED00002299
LZP    __
$a Pubmed-20161005

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...