-
Je něco špatně v tomto záznamu ?
Complications Associated with the Use of Supraglottic Airway Devices in Perioperative Medicine
P. Michalek, W. Donaldson, E. Vobrubova, M. Hakl,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem, přehledy
NLK
Free Medical Journals
od 2013
PubMed Central
od 2013
Europe PubMed Central
od 2013
ProQuest Central
od 2013
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2012-12-04
Open Access Digital Library
od 2013-01-01
CINAHL Plus with Full Text (EBSCOhost)
od 2013-01-01
Medline Complete (EBSCOhost)
od 2013-01-01
Health & Medicine (ProQuest)
od 2013
Wiley-Blackwell Open Access Titles
od 2001
ROAD: Directory of Open Access Scholarly Resources
od 2013
PubMed
26783527
DOI
10.1155/2015/746560
Knihovny.cz E-zdroje
- MeSH
- elektivní chirurgické výkony MeSH
- extubace škodlivé účinky přístrojové vybavení MeSH
- faryngitida patologie MeSH
- farynx patologie chirurgie MeSH
- lidé MeSH
- perioperační období MeSH
- pooperační komplikace patofyziologie MeSH
- poruchy polykání patologie terapie MeSH
- zajištění dýchacích cest * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
Supraglottic airway devices are routinely used for airway maintenance in elective surgical procedures where aspiration is not a significant risk and also as rescue devices in difficult airway management. Some devices now have features mitigating risk of aspiration, such as drain tubes or compartments to manage regurgitated content. Despite this, the use of these device may be associated with various complications including aspiration. This review highlights the types and incidence of these complications. They include regurgitation and aspiration of gastric contents, compression of vascular structures, trauma, and nerve injury. The incidence of such complications is quite low, but as some carry with them a significant degree of morbidity the need to follow manufacturers' advice is underlined. The incidence of gastric content aspiration associated with the devices is estimated to be as low as 0.02% with perioperative regurgitation being significantly higher but underreported. Other serious, but extremely rare, complications include pharyngeal rupture, pneumomediastinum, mediastinitis, or arytenoid dislocation. Mild short-lasting adverse effects of the devices have significantly higher incidence than serious complications and involve postoperative sore throat, dysphagia, pain on swallowing, or hoarseness. Devices may have deleterious effect on cervical mucosa or vasculature depending on their cuff volume and pressure.
Department of Anaesthetics Antrim Area Hospital Bush Road Antrim BT41 4RD UK
University of East Anglia Norwich Research Park Norwich Norfolk NR4 7TJ UK
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17000625
- 003
- CZ-PrNML
- 005
- 20170113094713.0
- 007
- ta
- 008
- 170103s2015 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1155/2015/746560 $2 doi
- 024 7_
- $a 10.1155/2015/746560 $2 doi
- 035 __
- $a (PubMed)26783527
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Michalek, Pavel $u Department of Anaesthesia and Intensive Medicine, 1st Medical Faculty, Charles University in Prague and General University Hospital, U Nemocnice 2, 120 21 Prague, Czech Republic; University of East Anglia, Norwich Research Park, Norwich, Norfolk NR4 7TJ, UK.
- 245 10
- $a Complications Associated with the Use of Supraglottic Airway Devices in Perioperative Medicine / $c P. Michalek, W. Donaldson, E. Vobrubova, M. Hakl,
- 520 9_
- $a Supraglottic airway devices are routinely used for airway maintenance in elective surgical procedures where aspiration is not a significant risk and also as rescue devices in difficult airway management. Some devices now have features mitigating risk of aspiration, such as drain tubes or compartments to manage regurgitated content. Despite this, the use of these device may be associated with various complications including aspiration. This review highlights the types and incidence of these complications. They include regurgitation and aspiration of gastric contents, compression of vascular structures, trauma, and nerve injury. The incidence of such complications is quite low, but as some carry with them a significant degree of morbidity the need to follow manufacturers' advice is underlined. The incidence of gastric content aspiration associated with the devices is estimated to be as low as 0.02% with perioperative regurgitation being significantly higher but underreported. Other serious, but extremely rare, complications include pharyngeal rupture, pneumomediastinum, mediastinitis, or arytenoid dislocation. Mild short-lasting adverse effects of the devices have significantly higher incidence than serious complications and involve postoperative sore throat, dysphagia, pain on swallowing, or hoarseness. Devices may have deleterious effect on cervical mucosa or vasculature depending on their cuff volume and pressure.
- 650 _2
- $a extubace $x škodlivé účinky $x přístrojové vybavení $7 D060666
- 650 12
- $a zajištění dýchacích cest $7 D058109
- 650 _2
- $a poruchy polykání $x patologie $x terapie $7 D003680
- 650 _2
- $a elektivní chirurgické výkony $7 D017558
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a perioperační období $7 D059035
- 650 _2
- $a faryngitida $x patologie $7 D010612
- 650 _2
- $a farynx $x patologie $x chirurgie $7 D010614
- 650 _2
- $a pooperační komplikace $x patofyziologie $7 D011183
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Donaldson, William $u Department of Anaesthetics, Antrim Area Hospital, Bush Road, Antrim BT41 4RD, UK.
- 700 1_
- $a Vobrubova, Eliska $u Department of Anaesthesia and Intensive Medicine, 1st Medical Faculty, Charles University in Prague and General University Hospital, U Nemocnice 2, 120 21 Prague, Czech Republic.
- 700 1_
- $a Hakl, Marek $u Department of Anaesthesia and Intensive Medicine, St. Anne University Hospital, Pekarska 53, 656 91 Brno, Czech Republic.
- 773 0_
- $w MED00182164 $t BioMed research international $x 2314-6141 $g Roč. 2015, č. - (2015), s. 746560
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26783527 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170103 $b ABA008
- 991 __
- $a 20170113094813 $b ABA008
- 999 __
- $a ok $b bmc $g 1179765 $s 961192
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 2015 $c - $d 746560 $e 20151213 $i 2314-6141 $m BioMed research international $n Biomed Res Int $x MED00182164
- LZP __
- $a Pubmed-20170103