Evaluation of a novel vascular graft with a distal bifurcation designed to reduce the development of intimal hyperplasia. Experimental study in a porcine aorta model
R. Vlachovsky, R. Staffa, M. Dvorak, M. Vlasin, M. Hermanova, T. O'Brien, T. McGloughlin
Jazyk angličtina Země Česko
Typ dokumentu hodnotící studie, časopisecké články
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 1998
Medline Complete (EBSCOhost)
od 2007-06-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
- MeSH
- aorta patologie chirurgie MeSH
- cévní endotel patologie MeSH
- cévní protézy škodlivé účinky MeSH
- hyperplazie MeSH
- prasata MeSH
- protézy - design MeSH
- studie proveditelnosti MeSH
- tunica intima patologie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
OBJECTIVE: Abnormal haemodynamics is commonly agreed to be a major contributor to the development of distal anastomotic intimal hyperplasia. A new vascular graft design proposed by computational studies was used to demonstrate its surgical feasibility and to compare it with the conventional graft in a porcine model. METHOD: The device was used in 12 eight-month-old pigs, six received the new graft and six had a conventional graft. The proximal graft end was implanted into the aorta, the distal graft end was implanted into the iliac artery. The host artery was ligated in order to simulate occlusion. At 20 weeks after surgery the pigs were killed and the device was excised for histological and morphometric analysis. RESULTS: In five experimental grafts the reconstruction was occluded due to thrombosis; only one prosthesis was patent showing a minimum of neointimal hyperplasia. In the control group too only three of the six grafts were patent. A histological analysis revealed, as the cause of occlusion, fibrous tissue overgrowth corresponding in structure to neointimal hyperplasia. Differences in the number of obliterations and in occlusion rates between the profiles of the two groups were evaluated using the median test (P<0.05). The results were not statistically significant. CONCLUSION: Although mathematical modelling had shown significant haemodynamic benefits of a naturally bifurcated graft, our study did not confirm its superiority over conventionally used prostheses.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17006114
- 003
- CZ-PrNML
- 005
- 20170307121818.0
- 007
- ta
- 008
- 170210s2014 xr a f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2013.021 $2 doi
- 035 __
- $a (PubMed)23579111
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Vlachovský, Robert, $u Second Department of Surgery, St. Anne's University Hospital in Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic $d 1977- $7 xx0087411
- 245 10
- $a Evaluation of a novel vascular graft with a distal bifurcation designed to reduce the development of intimal hyperplasia. Experimental study in a porcine aorta model / $c R. Vlachovsky, R. Staffa, M. Dvorak, M. Vlasin, M. Hermanova, T. O'Brien, T. McGloughlin
- 520 9_
- $a OBJECTIVE: Abnormal haemodynamics is commonly agreed to be a major contributor to the development of distal anastomotic intimal hyperplasia. A new vascular graft design proposed by computational studies was used to demonstrate its surgical feasibility and to compare it with the conventional graft in a porcine model. METHOD: The device was used in 12 eight-month-old pigs, six received the new graft and six had a conventional graft. The proximal graft end was implanted into the aorta, the distal graft end was implanted into the iliac artery. The host artery was ligated in order to simulate occlusion. At 20 weeks after surgery the pigs were killed and the device was excised for histological and morphometric analysis. RESULTS: In five experimental grafts the reconstruction was occluded due to thrombosis; only one prosthesis was patent showing a minimum of neointimal hyperplasia. In the control group too only three of the six grafts were patent. A histological analysis revealed, as the cause of occlusion, fibrous tissue overgrowth corresponding in structure to neointimal hyperplasia. Differences in the number of obliterations and in occlusion rates between the profiles of the two groups were evaluated using the median test (P<0.05). The results were not statistically significant. CONCLUSION: Although mathematical modelling had shown significant haemodynamic benefits of a naturally bifurcated graft, our study did not confirm its superiority over conventionally used prostheses.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a aorta $x patologie $x chirurgie $7 D001011
- 650 _2
- $a cévní protézy $x škodlivé účinky $7 D001807
- 650 _2
- $a cévní endotel $x patologie $7 D004730
- 650 _2
- $a studie proveditelnosti $7 D005240
- 650 _2
- $a hyperplazie $7 D006965
- 650 _2
- $a protézy - design $7 D011474
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a tunica intima $x patologie $7 D017539
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Staffa, Robert, $d 1961- $7 mzk2004248940 $u Second Department of Surgery, St. Anne's University Hospital in Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Dvořák, Martin, $d 1969- $7 xx0087410 $u Second Department of Surgery, St. Anne's University Hospital in Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Vlašín, Michal $7 _AN027851 $u Dogs & Cats Clinic, Faculty of Veterinary Medicine, University of Veterinary and Pharmaceutical Sciences Brno
- 700 1_
- $a Hermanová, Markéta $7 xx0073982 $u First Department of Pathological Anatomy, St. Anne´s University Hospital in Brno and Faculty of Medicine, Masaryk University, Brno
- 700 1_
- $a O'Brien, Thomas $u Centre for Applied Biomedical Engineering Research, Department of Mechanical and Aeronautical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
- 700 1_
- $a McGloughlin, Timothy $u Centre for Applied Biomedical Engineering Research, Department of Mechanical and Aeronautical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czech Republic $x 1213-8118 $g Roč. 158, č. 4 (2014), s. 562-568
- 856 41
- $u http://biomed.papers.upol.cz/ $y domovská stránka časopisu
- 910 __
- $a ABA008 $b A 1502 $c 958 $y 4 $z 0
- 990 __
- $a 20170210 $b ABA008
- 991 __
- $a 20170222143118 $b ABA008
- 999 __
- $a ok $b bmc $g 1192301 $s 966761
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 158 $c 4 $d 562-568 $e 20130410 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- LZP __
- $b NLK118 $a Pubmed-20170210