• Je něco špatně v tomto záznamu ?

T1 mapping of the ischemic myocardium: Review of potential clinical use

J. Baxa, J. Ferda, M. Hromádka,

. 2016 ; 85 (10) : 1922-8. [pub] 20160414

Jazyk angličtina Země Irsko

Typ dokumentu časopisecké články, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc17013927

Cardiac magnetic resonance imaging (CMR) is an indispensable part of the diagnostic algorithm in cardiology. CMR has become a gold standard in various disorders; moreover, it is well established also as a surrogate end-point in experimental and clinical studies. Particularly, the ability to directly display myocardial injury is a unique feature in comparison with other methods. The mapping of magnetic relaxation properties (T1, T2 and T2* relaxation times) are still relatively new techniques, but promising to improve the robustness of CMR and add new appropriate indications. The high potential of T1 mapping in the diagnostic of myocardial ischemic involvement has been highlighted in several experimental and clinical studies, but the use in clinical routine was limited due to the shortcomings in scanning and image evaluation. However, the quantitative technique of T1 mapping is now commercially available and its simple use, good reproducibility and limited subjectivity allow its incorporation into routine CMR protocols. This review article is aimed to summarise existing results and clinical experience with T1 mapping in patients with ischemic cardiac disease.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17013927
003      
CZ-PrNML
005      
20170502093811.0
007      
ta
008      
170413s2016 ie f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ejrad.2016.04.010 $2 doi
035    __
$a (PubMed)27105590
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ie
100    1_
$a Baxa, Jan $u Department of Imaging Methods, Faculty of Medicine in Pilsen, Charles University in Prague and University Hospital Pilsen, Czech Republic. Electronic address: baxaj@fnplzen.cz.
245    10
$a T1 mapping of the ischemic myocardium: Review of potential clinical use / $c J. Baxa, J. Ferda, M. Hromádka,
520    9_
$a Cardiac magnetic resonance imaging (CMR) is an indispensable part of the diagnostic algorithm in cardiology. CMR has become a gold standard in various disorders; moreover, it is well established also as a surrogate end-point in experimental and clinical studies. Particularly, the ability to directly display myocardial injury is a unique feature in comparison with other methods. The mapping of magnetic relaxation properties (T1, T2 and T2* relaxation times) are still relatively new techniques, but promising to improve the robustness of CMR and add new appropriate indications. The high potential of T1 mapping in the diagnostic of myocardial ischemic involvement has been highlighted in several experimental and clinical studies, but the use in clinical routine was limited due to the shortcomings in scanning and image evaluation. However, the quantitative technique of T1 mapping is now commercially available and its simple use, good reproducibility and limited subjectivity allow its incorporation into routine CMR protocols. This review article is aimed to summarise existing results and clinical experience with T1 mapping in patients with ischemic cardiac disease.
650    _2
$a srdce $x diagnostické zobrazování $7 D006321
650    _2
$a lidé $7 D006801
650    _2
$a magnetická rezonanční tomografie $x metody $7 D008279
650    _2
$a ischemická choroba srdeční $x diagnostické zobrazování $x patologie $7 D017202
650    _2
$a myokard $x patologie $7 D009206
650    _2
$a reprodukovatelnost výsledků $7 D015203
655    _2
$a časopisecké články $7 D016428
655    _2
$a přehledy $7 D016454
700    1_
$a Ferda, Jiří $u Department of Imaging Methods, Faculty of Medicine in Pilsen, Charles University in Prague and University Hospital Pilsen, Czech Republic.
700    1_
$a Hromádka, Milan $u Department of Cardiology, University Hospital Pilsen, Czech Republic.
773    0_
$w MED00009640 $t European journal of radiology $x 1872-7727 $g Roč. 85, č. 10 (2016), s. 1922-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27105590 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170413 $b ABA008
991    __
$a 20170502094138 $b ABA008
999    __
$a ok $b bmc $g 1200392 $s 974705
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 85 $c 10 $d 1922-8 $e 20160414 $i 1872-7727 $m European journal of radiology $n Eur J Radiol $x MED00009640
LZP    __
$a Pubmed-20170413

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...