Something wrong with this record ?
Exposure to airborne fungi during sorting of recyclable plastics in waste treatment facilities
K. Černá, Z. Wittlingerová, M. Zimová, Z. Janovský,
Language English Country Poland
Document type Journal Article
NLK
Directory of Open Access Journals
from 2013
ProQuest Central
from 2006-01-01
Open Access Digital Library
from 2013-01-01
Medline Complete (EBSCOhost)
from 2004-01-01
Health & Medicine (ProQuest)
from 2006-01-01
Psychology Database (ProQuest)
from 2006-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2001
- MeSH
- Fungi isolation & purification MeSH
- Air Pollutants, Occupational isolation & purification MeSH
- Humans MeSH
- Air Microbiology * MeSH
- Environmental Monitoring methods MeSH
- Plastics analysis MeSH
- Colony Count, Microbial MeSH
- Occupational Exposure statistics & numerical data MeSH
- Waste Disposal Facilities * MeSH
- Solid Waste analysis MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Poland MeSH
BACKGROUND: In working environment of waste treatment facilities, employees are exposed to high concentrations of airborne microorganisms. Fungi constitute an essential part of them. This study aims at evaluating the diurnal variation in concentrations and species composition of the fungal contamination in 2 plastic waste sorting facilities in different seasons. MATERIAL AND METHODS: Air samples from the 2 sorting facilities were collected through the membrane filters method on 4 different types of cultivation media. Isolated fungi were classified to genera or species by using a light microscopy. RESULTS: Overall, the highest concentrations of airborne fungi were recorded in summer (9.1×103-9.0×105 colony-forming units (CFU)/m3), while the lowest ones in winter (2.7×103-2.9×105 CFU/m3). The concentration increased from the beginning of the work shift and reached a plateau after 6-7 h of the sorting. The most frequently isolated airborne fungi were those of the genera Penicillium and Aspergillus. The turnover of fungal species between seasons was relatively high as well as changes in the number of detected species, but potentially toxigenic and allergenic fungi were detected in both facilities during all seasons. CONCLUSIONS: Generally, high concentrations of airborne fungi were detected in the working environment of plastic waste sorting facilities, which raises the question of health risk taken by the employees. Based on our results, the use of protective equipment by employees is recommended and preventive measures should be introduced into the working environment of waste sorting facilities to reduce health risk for employees. Med Pr 2017;68(1):1-9.
Charles University Prague Prague Czech Republic
Czech University of Life Sciences Prague Prague Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17023248
- 003
- CZ-PrNML
- 005
- 20170908104337.0
- 007
- ta
- 008
- 170720s2017 pl f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.13075/mp.5893.00520 $2 doi
- 035 __
- $a (PubMed)28244999
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a pl
- 100 1_
- $a Černá, Kristýna $u Czech University of Life Sciences Prague, Prague, Czech Republic (Faculty of Environmental Sciences, Department of Applied Ecology). cernakristyna@fzp.czu.cz.
- 245 10
- $a Exposure to airborne fungi during sorting of recyclable plastics in waste treatment facilities / $c K. Černá, Z. Wittlingerová, M. Zimová, Z. Janovský,
- 520 9_
- $a BACKGROUND: In working environment of waste treatment facilities, employees are exposed to high concentrations of airborne microorganisms. Fungi constitute an essential part of them. This study aims at evaluating the diurnal variation in concentrations and species composition of the fungal contamination in 2 plastic waste sorting facilities in different seasons. MATERIAL AND METHODS: Air samples from the 2 sorting facilities were collected through the membrane filters method on 4 different types of cultivation media. Isolated fungi were classified to genera or species by using a light microscopy. RESULTS: Overall, the highest concentrations of airborne fungi were recorded in summer (9.1×10<sup>3</sup>-9.0×10<sup>5</sup> colony-forming units (CFU)/m<sub>3</sub>), while the lowest ones in winter (2.7×10<sup>3</sup>-2.9×10<sup>5</sup> CFU/m<sup>3</sup>). The concentration increased from the beginning of the work shift and reached a plateau after 6-7 h of the sorting. The most frequently isolated airborne fungi were those of the genera Penicillium and Aspergillus. The turnover of fungal species between seasons was relatively high as well as changes in the number of detected species, but potentially toxigenic and allergenic fungi were detected in both facilities during all seasons. CONCLUSIONS: Generally, high concentrations of airborne fungi were detected in the working environment of plastic waste sorting facilities, which raises the question of health risk taken by the employees. Based on our results, the use of protective equipment by employees is recommended and preventive measures should be introduced into the working environment of waste sorting facilities to reduce health risk for employees. Med Pr 2017;68(1):1-9.
- 650 12
- $a mikrobiologie vzduchu $7 D000391
- 650 _2
- $a látky znečišťující vzduch v pracovním prostředí $x izolace a purifikace $7 D000395
- 650 _2
- $a počet mikrobiálních kolonií $7 D015169
- 650 _2
- $a monitorování životního prostředí $x metody $7 D004784
- 650 _2
- $a houby $x izolace a purifikace $7 D005658
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a pracovní expozice $x statistika a číselné údaje $7 D016273
- 650 _2
- $a plastické hmoty $x analýza $7 D010969
- 650 _2
- $a Polsko $7 D011044
- 650 _2
- $a tuhý odpad $x analýza $7 D062611
- 650 12
- $a skládková zařízení $7 D064091
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Wittlingerová, Zdeňka $u Czech University of Life Sciences Prague, Prague, Czech Republic (Faculty of Environmental Sciences, Department of Applied Ecology).
- 700 1_
- $a Zimová, Magdaléna $u Czech University of Life Sciences Prague, Prague, Czech Republic (Faculty of Environmental Sciences, Department of Applied Ecology).
- 700 1_
- $a Janovský, Zdeněk $u Charles University in Prague, Prague, Czech Republic (Faculty of Science, Department of Botany).
- 773 0_
- $w MED00003320 $t Medycyna pracy $x 0465-5893 $g Roč. 68, č. 1 (2017), s. 1-9
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28244999 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170720 $b ABA008
- 991 __
- $a 20170908104938 $b ABA008
- 999 __
- $a ok $b bmc $g 1238929 $s 984161
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 68 $c 1 $d 1-9 $e 20170228 $i 0465-5893 $m Medycyna pracy $n Med Pr $x MED00003320
- LZP __
- $a Pubmed-20170720