• Je něco špatně v tomto záznamu ?

MONTE CARLO SIMULATION OF THE BREMSSTRAHLUNG RADIATION FOR THE MEASUREMENT OF AN INTERNAL CONTAMINATION WITH PURE-BETA EMITTERS IN VIVO

K. Fantínová, P. Fojtík, I. Malátová,

. 2016 ; 170 (1-4) : 354-8. [pub] 20151005

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc17024224

Rapid measurement techniques are required for a large-scale emergency monitoring of people. In vivo measurement of the bremsstrahlung radiation produced by incorporated pure-beta emitters can offer a rapid technique for the determination of such radionuclides in the human body. This work presents a method for the calibration of spectrometers, based on the use of UPh-02T (so-called IGOR) phantom and specific (90)Sr/(90)Y sources, which can account for recent as well as previous contaminations. The process of the whole- and partial-body counter calibration in combination with application of a Monte Carlo code offers readily extension also to other pure-beta emitters and various exposure scenarios.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17024224
003      
CZ-PrNML
005      
20170720123700.0
007      
ta
008      
170720s2016 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/ncv427 $2 doi
035    __
$a (PubMed)26443547
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Fantínová, K $u SÚRO (National Radiation Protection Institute), Bartoškova 28, Prague 140 00, Czech Republic karin.fantinova@suro.cz.
245    10
$a MONTE CARLO SIMULATION OF THE BREMSSTRAHLUNG RADIATION FOR THE MEASUREMENT OF AN INTERNAL CONTAMINATION WITH PURE-BETA EMITTERS IN VIVO / $c K. Fantínová, P. Fojtík, I. Malátová,
520    9_
$a Rapid measurement techniques are required for a large-scale emergency monitoring of people. In vivo measurement of the bremsstrahlung radiation produced by incorporated pure-beta emitters can offer a rapid technique for the determination of such radionuclides in the human body. This work presents a method for the calibration of spectrometers, based on the use of UPh-02T (so-called IGOR) phantom and specific (90)Sr/(90)Y sources, which can account for recent as well as previous contaminations. The process of the whole- and partial-body counter calibration in combination with application of a Monte Carlo code offers readily extension also to other pure-beta emitters and various exposure scenarios.
650    _2
$a beta částice $7 D001610
650    _2
$a kalibrace $7 D002138
650    _2
$a elektromagnetické záření $7 D060733
650    _2
$a lidé $7 D006801
650    _2
$a metoda Monte Carlo $7 D009010
650    _2
$a fantomy radiodiagnostické $7 D019047
650    _2
$a dávka záření $7 D011829
650    _2
$a monitorování radiace $x přístrojové vybavení $x metody $7 D011834
650    _2
$a radiační ochrana $x přístrojové vybavení $x metody $7 D011835
650    _2
$a radionuklidy $7 D011868
650    _2
$a radioizotopy stroncia $x analýza $7 D013326
650    _2
$a celotělové počítání $x přístrojové vybavení $x metody $7 D014915
650    _2
$a radioizotopy ytria $x analýza $7 D015021
655    _2
$a časopisecké články $7 D016428
700    1_
$a Fojtík, P $u SÚRO (National Radiation Protection Institute), Bartoškova 28, Prague 140 00, Czech Republic.
700    1_
$a Malátová, I $u SÚRO (National Radiation Protection Institute), Bartoškova 28, Prague 140 00, Czech Republic.
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 170, č. 1-4 (2016), s. 354-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26443547 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170720 $b ABA008
991    __
$a 20170720124153 $b ABA008
999    __
$a ok $b bmc $g 1239905 $s 985137
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 170 $c 1-4 $d 354-8 $e 20151005 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20170720

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...