Experimental analysis of the lumbar spine kinematics
Lubos Tomsovsky, Petr Kubovy, Martin Otahal
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem
- MeSH
- bederní obratle anatomie a histologie fyziologie MeSH
- biologické modely MeSH
- bolesti zad * etiologie patofyziologie MeSH
- kinetika MeSH
- lidé MeSH
- lumbalgie MeSH
- rotace MeSH
- točivý moment MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
Pain-provoking disorders of the lumbar spine affect most of adult population and nearly everyone suffers from some of them during their lifetime. A common symptom of diseases, injuries or inevitable changes in the area of lumbar spine is known as the Low Back Pain (LBP). A chronic form of the LBP, called the Low Back Pain syndrome, is mostly caused by degenerative changes of intervertebral discs of the lowest intervertebral joints. The work was focused on in vitro analysis of the porcine lumbar spine kinematics. Two last neighbouring intervertebral joints without active tissue, L4/5 and L5/6, were used. The total number of fifteen cadaveric samples of porcine lumbar spine was involved. A unique loading mechanism was designed and constructed for the purposes of this study. Samples were loaded by flexion/extension movement within the physiological range of motion of ± 5°, in a quasi-static mode. The recording and analysing of the lumbar spine kinematics was realized by the motion capture camera system (Qualisys AB, Göteborg, Sweden). The results showed that the so-called instantaneous axis of rotation (IAR), or the corresponding instantaneous centre of rotation (ICR), was an adequate objective parameter for the assessment of the lumbar spine kinematics. Its position was comparable across all samples and situated very close to the spinal canal. For the purposes of this work, an altered artificial disc of a ball-and-socket type (ProSpon, Ltd., Kladno, Czech Republic) was used to study the kinematics of two neighbouring joints after the disc replacement in the area of a caudally situated one. The results of this comparative analysis showed a significant influence of the artificial disc on the kinematics of both, caudally situated joint, where the disc was implanted, and the adjacent one.
Charles University Prague Faculty of Physical Education and Sport Prague Czech Republic
Czech Technical University Prague Faculty of Biomedical Engineering Kladno Czech Republic
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17028389
- 003
- CZ-PrNML
- 005
- 20171020145604.0
- 007
- ta
- 008
- 170927s2017 xr a f 000 0|eng||
- 009
- AR
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Tomšovský, Luboš. $7 xx0230776 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
- 245 10
- $a Experimental analysis of the lumbar spine kinematics / $c Lubos Tomsovsky, Petr Kubovy, Martin Otahal
- 504 __
- $a Literatura
- 520 9_
- $a Pain-provoking disorders of the lumbar spine affect most of adult population and nearly everyone suffers from some of them during their lifetime. A common symptom of diseases, injuries or inevitable changes in the area of lumbar spine is known as the Low Back Pain (LBP). A chronic form of the LBP, called the Low Back Pain syndrome, is mostly caused by degenerative changes of intervertebral discs of the lowest intervertebral joints. The work was focused on in vitro analysis of the porcine lumbar spine kinematics. Two last neighbouring intervertebral joints without active tissue, L4/5 and L5/6, were used. The total number of fifteen cadaveric samples of porcine lumbar spine was involved. A unique loading mechanism was designed and constructed for the purposes of this study. Samples were loaded by flexion/extension movement within the physiological range of motion of ± 5°, in a quasi-static mode. The recording and analysing of the lumbar spine kinematics was realized by the motion capture camera system (Qualisys AB, Göteborg, Sweden). The results showed that the so-called instantaneous axis of rotation (IAR), or the corresponding instantaneous centre of rotation (ICR), was an adequate objective parameter for the assessment of the lumbar spine kinematics. Its position was comparable across all samples and situated very close to the spinal canal. For the purposes of this work, an altered artificial disc of a ball-and-socket type (ProSpon, Ltd., Kladno, Czech Republic) was used to study the kinematics of two neighbouring joints after the disc replacement in the area of a caudally situated one. The results of this comparative analysis showed a significant influence of the artificial disc on the kinematics of both, caudally situated joint, where the disc was implanted, and the adjacent one.
- 650 12
- $a bolesti zad $x etiologie $x patofyziologie $7 D001416
- 650 _2
- $a bederní obratle $x anatomie a histologie $x fyziologie $7 D008159
- 650 _2
- $a rotace $7 D012399
- 650 _2
- $a točivý moment $7 D019415
- 650 _2
- $a kinetika $7 D007700
- 650 _2
- $a biologické modely $7 D008954
- 650 _2
- $a lumbalgie $7 D017116
- 650 _2
- $a lidé $7 D006801
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Kubový, Petr $7 xx0105133 $u Charles University in Prague, Faculty of Physical Education and Sport, Prague, Czech Republic
- 700 1_
- $a Otáhal, Martin $7 _AN047414 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
- 773 0_
- $t Lékař a technika $x 0301-5491 $g Roč. 47, č. 2 (2017), s. 49-55 $w MED00011033
- 856 41
- $u https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/4417/4277 $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y 4 $z 0
- 990 __
- $a 20170927055442 $b ABA008
- 991 __
- $a 20171020145638 $b ABA008
- 999 __
- $a ok $b bmc $g 1249660 $s 989391
- BAS __
- $a 3
- BMC __
- $a 2017 $b 47 $c 2 $d 49-55 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
- LZP __
- $c NLK125 $d 20171020 $a NLK 2017-43/vt