Experimental analysis of the lumbar spine kinematics

Lubos Tomsovsky, Petr Kubovy, Martin Otahal

. 2017 ; 47 (2) : 49-55.

Jazyk angličtina Země Česko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc17028389

Pain-provoking disorders of the lumbar spine affect most of adult population and nearly everyone suffers from some of them during their lifetime. A common symptom of diseases, injuries or inevitable changes in the area of lumbar spine is known as the Low Back Pain (LBP). A chronic form of the LBP, called the Low Back Pain syndrome, is mostly caused by degenerative changes of intervertebral discs of the lowest intervertebral joints. The work was focused on in vitro analysis of the porcine lumbar spine kinematics. Two last neighbouring intervertebral joints without active tissue, L4/5 and L5/6, were used. The total number of fifteen cadaveric samples of porcine lumbar spine was involved. A unique loading mechanism was designed and constructed for the purposes of this study. Samples were loaded by flexion/extension movement within the physiological range of motion of ± 5°, in a quasi-static mode. The recording and analysing of the lumbar spine kinematics was realized by the motion capture camera system (Qualisys AB, Göteborg, Sweden). The results showed that the so-called instantaneous axis of rotation (IAR), or the corresponding instantaneous centre of rotation (ICR), was an adequate objective parameter for the assessment of the lumbar spine kinematics. Its position was comparable across all samples and situated very close to the spinal canal. For the purposes of this work, an altered artificial disc of a ball-and-socket type (ProSpon, Ltd., Kladno, Czech Republic) was used to study the kinematics of two neighbouring joints after the disc replacement in the area of a caudally situated one. The results of this comparative analysis showed a significant influence of the artificial disc on the kinematics of both, caudally situated joint, where the disc was implanted, and the adjacent one.

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc17028389
003      
CZ-PrNML
005      
20171020145604.0
007      
ta
008      
170927s2017 xr a f 000 0|eng||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Tomšovský, Luboš. $7 xx0230776 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
245    10
$a Experimental analysis of the lumbar spine kinematics / $c Lubos Tomsovsky, Petr Kubovy, Martin Otahal
504    __
$a Literatura
520    9_
$a Pain-provoking disorders of the lumbar spine affect most of adult population and nearly everyone suffers from some of them during their lifetime. A common symptom of diseases, injuries or inevitable changes in the area of lumbar spine is known as the Low Back Pain (LBP). A chronic form of the LBP, called the Low Back Pain syndrome, is mostly caused by degenerative changes of intervertebral discs of the lowest intervertebral joints. The work was focused on in vitro analysis of the porcine lumbar spine kinematics. Two last neighbouring intervertebral joints without active tissue, L4/5 and L5/6, were used. The total number of fifteen cadaveric samples of porcine lumbar spine was involved. A unique loading mechanism was designed and constructed for the purposes of this study. Samples were loaded by flexion/extension movement within the physiological range of motion of ± 5°, in a quasi-static mode. The recording and analysing of the lumbar spine kinematics was realized by the motion capture camera system (Qualisys AB, Göteborg, Sweden). The results showed that the so-called instantaneous axis of rotation (IAR), or the corresponding instantaneous centre of rotation (ICR), was an adequate objective parameter for the assessment of the lumbar spine kinematics. Its position was comparable across all samples and situated very close to the spinal canal. For the purposes of this work, an altered artificial disc of a ball-and-socket type (ProSpon, Ltd., Kladno, Czech Republic) was used to study the kinematics of two neighbouring joints after the disc replacement in the area of a caudally situated one. The results of this comparative analysis showed a significant influence of the artificial disc on the kinematics of both, caudally situated joint, where the disc was implanted, and the adjacent one.
650    12
$a bolesti zad $x etiologie $x patofyziologie $7 D001416
650    _2
$a bederní obratle $x anatomie a histologie $x fyziologie $7 D008159
650    _2
$a rotace $7 D012399
650    _2
$a točivý moment $7 D019415
650    _2
$a kinetika $7 D007700
650    _2
$a biologické modely $7 D008954
650    _2
$a lumbalgie $7 D017116
650    _2
$a lidé $7 D006801
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Kubový, Petr $7 xx0105133 $u Charles University in Prague, Faculty of Physical Education and Sport, Prague, Czech Republic
700    1_
$a Otáhal, Martin $7 _AN047414 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 47, č. 2 (2017), s. 49-55 $w MED00011033
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/4417/4277 $y plný text volně přístupný
910    __
$a ABA008 $b B 1367 $c 1071 b $y 4 $z 0
990    __
$a 20170927055442 $b ABA008
991    __
$a 20171020145638 $b ABA008
999    __
$a ok $b bmc $g 1249660 $s 989391
BAS    __
$a 3
BMC    __
$a 2017 $b 47 $c 2 $d 49-55 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$c NLK125 $d 20171020 $a NLK 2017-43/vt

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...