Something wrong with this record ?
A novel liquid chromatography/mass spectrometry method for determination of neurotransmitters in brain tissue: Application to human tauopathies
A. Forgacsova, J. Galba, RM. Garruto, P. Majerova, S. Katina, A. Kovac,
Language English Country Netherlands
Document type Journal Article
- MeSH
- Chromatography, Liquid methods MeSH
- Mass Spectrometry methods MeSH
- Humans MeSH
- Limit of Detection MeSH
- Linear Models MeSH
- Brain Chemistry physiology MeSH
- Neurotransmitter Agents analysis metabolism MeSH
- Reproducibility of Results MeSH
- Tauopathies metabolism MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
Neurotransmitters, small molecules widely distributed in the central nervous system are essential in transmitting electrical signals across neurons via chemical communication. Dysregulation of these chemical signaling molecules is linked to numerous neurological diseases including tauopathies. In this study, a precise and reliable liquid chromatography method was established with tandem mass spectrometry detection for the simultaneous determination of aspartic acid, asparagine, glutamic acid, glutamine, γ-aminobutyric acid, N-acetyl-l-aspartic acid, pyroglutamic acid, acetylcholine and choline in human brain tissue. The method was successfully applied to the analysis of human brain tissues from three different tauopathies; corticobasal degeneration, progressive supranuclear palsy and parkinsonism-dementia complex of Guam. Neurotransmitters were analyzed on ultra-high performance chromatography (UHPLC) using an ethylene bridged hybrid amide column coupled with tandem mass spectrometry (MS/MS). Identification and quantification of neurotransmitters was carried out by ESI+ mass spectrometry detection. We optimized sample preparation to achieve simple and fast extraction of all nine analytes. Our method exhibited an excellent linearity for all analytes (all coefficients of determination >0.99), with inter-day and intra-day precision yielding relative standard deviations 3.2%-11.2% and an accuracy was in range of 92.6%-104.3%. The present study, using the above method, is the first to demonstrate significant alterations of brain neurotransmitters caused by pathological processes in the brain tissues of patient with three different tauopathies.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18010230
- 003
- CZ-PrNML
- 005
- 20180420101150.0
- 007
- ta
- 008
- 180404s2018 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jchromb.2017.12.015 $2 doi
- 035 __
- $a (PubMed)29275172
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Forgacsova, Andrea $u Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy of Comenius University, Odbojarov 10, 832 32, Bratislava, Slovak Republic. Electronic address: andrej.kovac@savba.sk.
- 245 12
- $a A novel liquid chromatography/mass spectrometry method for determination of neurotransmitters in brain tissue: Application to human tauopathies / $c A. Forgacsova, J. Galba, RM. Garruto, P. Majerova, S. Katina, A. Kovac,
- 520 9_
- $a Neurotransmitters, small molecules widely distributed in the central nervous system are essential in transmitting electrical signals across neurons via chemical communication. Dysregulation of these chemical signaling molecules is linked to numerous neurological diseases including tauopathies. In this study, a precise and reliable liquid chromatography method was established with tandem mass spectrometry detection for the simultaneous determination of aspartic acid, asparagine, glutamic acid, glutamine, γ-aminobutyric acid, N-acetyl-l-aspartic acid, pyroglutamic acid, acetylcholine and choline in human brain tissue. The method was successfully applied to the analysis of human brain tissues from three different tauopathies; corticobasal degeneration, progressive supranuclear palsy and parkinsonism-dementia complex of Guam. Neurotransmitters were analyzed on ultra-high performance chromatography (UHPLC) using an ethylene bridged hybrid amide column coupled with tandem mass spectrometry (MS/MS). Identification and quantification of neurotransmitters was carried out by ESI+ mass spectrometry detection. We optimized sample preparation to achieve simple and fast extraction of all nine analytes. Our method exhibited an excellent linearity for all analytes (all coefficients of determination >0.99), with inter-day and intra-day precision yielding relative standard deviations 3.2%-11.2% and an accuracy was in range of 92.6%-104.3%. The present study, using the above method, is the first to demonstrate significant alterations of brain neurotransmitters caused by pathological processes in the brain tissues of patient with three different tauopathies.
- 650 _2
- $a mozek - chemie $x fyziologie $7 D001923
- 650 _2
- $a chromatografie kapalinová $x metody $7 D002853
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a lineární modely $7 D016014
- 650 _2
- $a hmotnostní spektrometrie $x metody $7 D013058
- 650 _2
- $a neurotransmiterové látky $x analýza $x metabolismus $7 D018377
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a tauopatie $x metabolismus $7 D024801
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Galba, Jaroslav $u Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy of Comenius University, Odbojarov 10, 832 32, Bratislava, Slovak Republic; AXON Neuroscience R&D Services SE, Dvorakovo nabrezie 10, 811 02, Bratislava, Slovak Republic.
- 700 1_
- $a Garruto, Ralph M $u Graduate Program in Biomedical Anthropology, Departments of Anthropology and Biological Sciences, Binghamton University, Binghamton, NY, USA; Institute of Mathematics and Statistics, Faculty of Science, Masaryk University, Kotlářská 267/2, 611 37, Brno, Czech Republic.
- 700 1_
- $a Majerova, Petra $u Institute of Neuroimmunology, Slovak Academy of Sciences, Dubravska cesta 9, 84510, Bratislava, Slovak Republic; AXON Neuroscience R&D Services SE, Dvorakovo nabrezie 10, 811 02, Bratislava, Slovak Republic.
- 700 1_
- $a Katina, Stanislav $u Institute of Mathematics and Statistics, Faculty of Science, Masaryk University, Kotlářská 267/2, 611 37, Brno, Czech Republic.
- 700 1_
- $a Kovac, Andrej $u Institute of Neuroimmunology, Slovak Academy of Sciences, Dubravska cesta 9, 84510, Bratislava, Slovak Republic; Department of Pharmacology and Toxicology, The University of Veterinary Medicine and Pharmacy, Komenskeho 73, 04181, Kosice, Slovak Republic; AXON Neuroscience R&D Services SE, Dvorakovo nabrezie 10, 811 02, Bratislava, Slovak Republic.
- 773 0_
- $w MED00006642 $t Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $x 1873-376X $g Roč. 1073, č. - (2018), s. 154-162
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29275172 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180404 $b ABA008
- 991 __
- $a 20180420101252 $b ABA008
- 999 __
- $a ok $b bmc $g 1287715 $s 1007042
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 1073 $c - $d 154-162 $e 20171209 $i 1873-376X $m Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $n J Chromatogr B Analyt Technol Biomed Life Sci $x MED00006642
- LZP __
- $a Pubmed-20180404