• Something wrong with this record ?

A novel liquid chromatography/mass spectrometry method for determination of neurotransmitters in brain tissue: Application to human tauopathies

A. Forgacsova, J. Galba, RM. Garruto, P. Majerova, S. Katina, A. Kovac,

. 2018 ; 1073 (-) : 154-162. [pub] 20171209

Language English Country Netherlands

Document type Journal Article

Neurotransmitters, small molecules widely distributed in the central nervous system are essential in transmitting electrical signals across neurons via chemical communication. Dysregulation of these chemical signaling molecules is linked to numerous neurological diseases including tauopathies. In this study, a precise and reliable liquid chromatography method was established with tandem mass spectrometry detection for the simultaneous determination of aspartic acid, asparagine, glutamic acid, glutamine, γ-aminobutyric acid, N-acetyl-l-aspartic acid, pyroglutamic acid, acetylcholine and choline in human brain tissue. The method was successfully applied to the analysis of human brain tissues from three different tauopathies; corticobasal degeneration, progressive supranuclear palsy and parkinsonism-dementia complex of Guam. Neurotransmitters were analyzed on ultra-high performance chromatography (UHPLC) using an ethylene bridged hybrid amide column coupled with tandem mass spectrometry (MS/MS). Identification and quantification of neurotransmitters was carried out by ESI+ mass spectrometry detection. We optimized sample preparation to achieve simple and fast extraction of all nine analytes. Our method exhibited an excellent linearity for all analytes (all coefficients of determination >0.99), with inter-day and intra-day precision yielding relative standard deviations 3.2%-11.2% and an accuracy was in range of 92.6%-104.3%. The present study, using the above method, is the first to demonstrate significant alterations of brain neurotransmitters caused by pathological processes in the brain tissues of patient with three different tauopathies.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18010230
003      
CZ-PrNML
005      
20180420101150.0
007      
ta
008      
180404s2018 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jchromb.2017.12.015 $2 doi
035    __
$a (PubMed)29275172
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Forgacsova, Andrea $u Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy of Comenius University, Odbojarov 10, 832 32, Bratislava, Slovak Republic. Electronic address: andrej.kovac@savba.sk.
245    12
$a A novel liquid chromatography/mass spectrometry method for determination of neurotransmitters in brain tissue: Application to human tauopathies / $c A. Forgacsova, J. Galba, RM. Garruto, P. Majerova, S. Katina, A. Kovac,
520    9_
$a Neurotransmitters, small molecules widely distributed in the central nervous system are essential in transmitting electrical signals across neurons via chemical communication. Dysregulation of these chemical signaling molecules is linked to numerous neurological diseases including tauopathies. In this study, a precise and reliable liquid chromatography method was established with tandem mass spectrometry detection for the simultaneous determination of aspartic acid, asparagine, glutamic acid, glutamine, γ-aminobutyric acid, N-acetyl-l-aspartic acid, pyroglutamic acid, acetylcholine and choline in human brain tissue. The method was successfully applied to the analysis of human brain tissues from three different tauopathies; corticobasal degeneration, progressive supranuclear palsy and parkinsonism-dementia complex of Guam. Neurotransmitters were analyzed on ultra-high performance chromatography (UHPLC) using an ethylene bridged hybrid amide column coupled with tandem mass spectrometry (MS/MS). Identification and quantification of neurotransmitters was carried out by ESI+ mass spectrometry detection. We optimized sample preparation to achieve simple and fast extraction of all nine analytes. Our method exhibited an excellent linearity for all analytes (all coefficients of determination >0.99), with inter-day and intra-day precision yielding relative standard deviations 3.2%-11.2% and an accuracy was in range of 92.6%-104.3%. The present study, using the above method, is the first to demonstrate significant alterations of brain neurotransmitters caused by pathological processes in the brain tissues of patient with three different tauopathies.
650    _2
$a mozek - chemie $x fyziologie $7 D001923
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a lidé $7 D006801
650    _2
$a limita detekce $7 D057230
650    _2
$a lineární modely $7 D016014
650    _2
$a hmotnostní spektrometrie $x metody $7 D013058
650    _2
$a neurotransmiterové látky $x analýza $x metabolismus $7 D018377
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a tauopatie $x metabolismus $7 D024801
655    _2
$a časopisecké články $7 D016428
700    1_
$a Galba, Jaroslav $u Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy of Comenius University, Odbojarov 10, 832 32, Bratislava, Slovak Republic; AXON Neuroscience R&D Services SE, Dvorakovo nabrezie 10, 811 02, Bratislava, Slovak Republic.
700    1_
$a Garruto, Ralph M $u Graduate Program in Biomedical Anthropology, Departments of Anthropology and Biological Sciences, Binghamton University, Binghamton, NY, USA; Institute of Mathematics and Statistics, Faculty of Science, Masaryk University, Kotlářská 267/2, 611 37, Brno, Czech Republic.
700    1_
$a Majerova, Petra $u Institute of Neuroimmunology, Slovak Academy of Sciences, Dubravska cesta 9, 84510, Bratislava, Slovak Republic; AXON Neuroscience R&D Services SE, Dvorakovo nabrezie 10, 811 02, Bratislava, Slovak Republic.
700    1_
$a Katina, Stanislav $u Institute of Mathematics and Statistics, Faculty of Science, Masaryk University, Kotlářská 267/2, 611 37, Brno, Czech Republic.
700    1_
$a Kovac, Andrej $u Institute of Neuroimmunology, Slovak Academy of Sciences, Dubravska cesta 9, 84510, Bratislava, Slovak Republic; Department of Pharmacology and Toxicology, The University of Veterinary Medicine and Pharmacy, Komenskeho 73, 04181, Kosice, Slovak Republic; AXON Neuroscience R&D Services SE, Dvorakovo nabrezie 10, 811 02, Bratislava, Slovak Republic.
773    0_
$w MED00006642 $t Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $x 1873-376X $g Roč. 1073, č. - (2018), s. 154-162
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29275172 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180404 $b ABA008
991    __
$a 20180420101252 $b ABA008
999    __
$a ok $b bmc $g 1287715 $s 1007042
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 1073 $c - $d 154-162 $e 20171209 $i 1873-376X $m Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $n J Chromatogr B Analyt Technol Biomed Life Sci $x MED00006642
LZP    __
$a Pubmed-20180404

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...