The variability of automated QRS duration measurement
V. Vancura, D. Wichterle, I. Ulc, J. Šmíd, M. Brabec, M. Zárybnická, R. Rokyta,
Language English Country Great Britain
Document type Comparative Study, Evaluation Study, Journal Article
NLK
Free Medical Journals
from 1999 to 1 year ago
PubMed Central
from 2008
Open Access Digital Library
from 1999-01-01
Medline Complete (EBSCOhost)
from 1999-01-01
Oxford Journals Open Access Collection
from 1999-01-01
- MeSH
- Algorithms * MeSH
- Equipment Failure Analysis MeSH
- Equipment Design MeSH
- Diagnosis, Computer-Assisted instrumentation methods MeSH
- Electrocardiography instrumentation methods MeSH
- Humans MeSH
- Reproducibility of Results MeSH
- Pattern Recognition, Automated methods MeSH
- Aged MeSH
- Sensitivity and Specificity MeSH
- Check Tag
- Humans MeSH
- Aged MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Comparative Study MeSH
Aims: Previous studies have demonstrated substantial variability in manual assessment of QRS complex duration (QRSd). Disagreements in QRSd measurements were also found in several automated algorithms tested on digitized electrocardiogram (ECG) recordings. The aim of our study was to investigate the variability of automated QRSd measurements performed by two commercially available electrocardiographs. Methods and Results: Two GE MAC 5000 (GE-1 and GE-2) electrocardiographs and two Mortara ELI 350 (Mortara-1 and Mortara-2) electrocardiographs were used in the study. Participants for the study were recruited from patients hospitalized in the department of cardiology of a university hospital. Participants underwent up to four recording sessions within a single day with a different electrocardiograph at each session when two to four immediately successive ECG recordings were undertaken. In 76 patients, 683 ECGs were recorded; the mean QRSd was 109.0 ± 26.1 ms. The QRSd difference ≥10 ms between the first and second intra-session ECG was found in 7, 3, 20, and 14% of ECG pairs for GE-1, GE-2, Mortara-1, and Mortara-2, respectively. No inter-session difference in QRSd was found within both manufacturers. In individual patients, Mortara calculated the mean QRSd to be longer by 7.3 ms (95% CI: 6.2-8.5 ms, P < 0.0001) with a 2.1-times (95% CI: 1.9-2.4) greater standard deviation of the mean QRSd (7.1 vs. 3.3 ms, P < 0.001). Conclusion: Electrocardiographs from two manufacturers measured QRSd values with a systematic difference and a significantly different level of precision. This may have important clinical implications in selection of suitable candidates for cardiac resynchronization therapy.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18010660
- 003
- CZ-PrNML
- 005
- 20180418140400.0
- 007
- ta
- 008
- 180404s2017 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/europace/euw015 $2 doi
- 035 __
- $a (PubMed)28431054
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Vancura, Vlastimil $u Cardiology Department, Complex Cardiovascular Centre, University Hospital and Faculty of Medicine Pilsen, Charles University Prague, Alej Svobody 80, 304 60 Pilsen, Czech Republic. Department of Cardiology, Institute of Clinical and Experimental Medicine, Vídeňská 1958/9, 140 21 Praha 4, Czech Republic.
- 245 14
- $a The variability of automated QRS duration measurement / $c V. Vancura, D. Wichterle, I. Ulc, J. Šmíd, M. Brabec, M. Zárybnická, R. Rokyta,
- 520 9_
- $a Aims: Previous studies have demonstrated substantial variability in manual assessment of QRS complex duration (QRSd). Disagreements in QRSd measurements were also found in several automated algorithms tested on digitized electrocardiogram (ECG) recordings. The aim of our study was to investigate the variability of automated QRSd measurements performed by two commercially available electrocardiographs. Methods and Results: Two GE MAC 5000 (GE-1 and GE-2) electrocardiographs and two Mortara ELI 350 (Mortara-1 and Mortara-2) electrocardiographs were used in the study. Participants for the study were recruited from patients hospitalized in the department of cardiology of a university hospital. Participants underwent up to four recording sessions within a single day with a different electrocardiograph at each session when two to four immediately successive ECG recordings were undertaken. In 76 patients, 683 ECGs were recorded; the mean QRSd was 109.0 ± 26.1 ms. The QRSd difference ≥10 ms between the first and second intra-session ECG was found in 7, 3, 20, and 14% of ECG pairs for GE-1, GE-2, Mortara-1, and Mortara-2, respectively. No inter-session difference in QRSd was found within both manufacturers. In individual patients, Mortara calculated the mean QRSd to be longer by 7.3 ms (95% CI: 6.2-8.5 ms, P < 0.0001) with a 2.1-times (95% CI: 1.9-2.4) greater standard deviation of the mean QRSd (7.1 vs. 3.3 ms, P < 0.001). Conclusion: Electrocardiographs from two manufacturers measured QRSd values with a systematic difference and a significantly different level of precision. This may have important clinical implications in selection of suitable candidates for cardiac resynchronization therapy.
- 650 _2
- $a senioři $7 D000368
- 650 12
- $a algoritmy $7 D000465
- 650 _2
- $a diagnóza počítačová $x přístrojové vybavení $x metody $7 D003936
- 650 _2
- $a elektrokardiografie $x přístrojové vybavení $x metody $7 D004562
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a analýza selhání vybavení $7 D019544
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a rozpoznávání automatizované $x metody $7 D010363
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a senzitivita a specificita $7 D012680
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Wichterle, Dan $u Department of Cardiology, Institute of Clinical and Experimental Medicine, Vídeňská 1958/9, 140 21 Praha 4, Czech Republic. Department of Cardiology and Angiology, First Faculty of Medicine, Charles University, U Nemocnice 2, 128 08 Praha 2, Czech Republic.
- 700 1_
- $a Ulc, Ivan $u Cardiology Department, Complex Cardiovascular Centre, University Hospital and Faculty of Medicine Pilsen, Charles University Prague, Alej Svobody 80, 304 60 Pilsen, Czech Republic.
- 700 1_
- $a Šmíd, Jirí $u Cardiology Department, Complex Cardiovascular Centre, University Hospital and Faculty of Medicine Pilsen, Charles University Prague, Alej Svobody 80, 304 60 Pilsen, Czech Republic.
- 700 1_
- $a Brabec, Marek $u Department of Nonlinear Modeling, Institute of Computer Science, Academy of Sciences of the Czech Republic, Pod vodárenskou věží 2, 182 07 Praha 8, Czech Republic. Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University in Prague, Jugoslávských partyzánů 1580/3, 160 00 Praha 6, Czech Republic.
- 700 1_
- $a Zárybnická, Marta $u Department of Cardiac Surgery, Complex Cardiovascular Centre, University Hospital and Faculty of Medicine Pilsen, Charles University Prague, Alej Svobody 80, 304 60 Pilsen, Czech Republic.
- 700 1_
- $a Rokyta, Richard $u Cardiology Department, Complex Cardiovascular Centre, University Hospital and Faculty of Medicine Pilsen, Charles University Prague, Alej Svobody 80, 304 60 Pilsen, Czech Republic.
- 773 0_
- $w MED00149837 $t Europace $x 1532-2092 $g Roč. 19, č. 4 (2017), s. 636-643
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28431054 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180404 $b ABA008
- 991 __
- $a 20180418140500 $b ABA008
- 999 __
- $a ok $b bmc $g 1288145 $s 1007472
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 19 $c 4 $d 636-643 $i 1532-2092 $m Europace $n Europace $x MED00149837
- LZP __
- $a Pubmed-20180404