• Je něco špatně v tomto záznamu ?

Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography

I. Lhotská, A. Holznerová, P. Solich, D. Šatínský,

. 2017 ; 40 (23) : 4599-4609. [pub] 20171102

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18024594

Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18024594
003      
CZ-PrNML
005      
20180710095123.0
007      
ta
008      
180709s2017 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/jssc.201700940 $2 doi
035    __
$a (PubMed)28986945
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Lhotská, Ivona $u The Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského, Czech Republic.
245    10
$a Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography / $c I. Lhotská, A. Holznerová, P. Solich, D. Šatínský,
520    9_
$a Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail.
650    _2
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    12
$a molekulový imprinting $7 D054802
650    _2
$a patulin $x izolace a purifikace $7 D010365
650    _2
$a polymery $7 D011108
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    12
$a extrakce na pevné fázi $7 D052616
655    _2
$a časopisecké články $7 D016428
700    1_
$a Holznerová, Anežka $u The Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského, Czech Republic.
700    1_
$a Solich, Petr $u The Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského, Czech Republic.
700    1_
$a Šatínský, Dalibor $u The Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského, Czech Republic.
773    0_
$w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 40, č. 23 (2017), s. 4599-4609
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28986945 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180709 $b ABA008
991    __
$a 20180710095412 $b ABA008
999    __
$a ok $b bmc $g 1316725 $s 1021515
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 40 $c 23 $d 4599-4609 $e 20171102 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
LZP    __
$a Pubmed-20180709

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...