-
Je něco špatně v tomto záznamu ?
Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography
I. Lhotská, A. Holznerová, P. Solich, D. Šatínský,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články
PubMed
28986945
DOI
10.1002/jssc.201700940
Knihovny.cz E-zdroje
- MeSH
- extrakce na pevné fázi * MeSH
- molekulový imprinting * MeSH
- patulin izolace a purifikace MeSH
- polymery MeSH
- reprodukovatelnost výsledků MeSH
- vysokoúčinná kapalinová chromatografie MeSH
- Publikační typ
- časopisecké články MeSH
Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18024594
- 003
- CZ-PrNML
- 005
- 20180710095123.0
- 007
- ta
- 008
- 180709s2017 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/jssc.201700940 $2 doi
- 035 __
- $a (PubMed)28986945
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Lhotská, Ivona $u The Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského, Czech Republic.
- 245 10
- $a Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography / $c I. Lhotská, A. Holznerová, P. Solich, D. Šatínský,
- 520 9_
- $a Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail.
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $7 D002851
- 650 12
- $a molekulový imprinting $7 D054802
- 650 _2
- $a patulin $x izolace a purifikace $7 D010365
- 650 _2
- $a polymery $7 D011108
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 12
- $a extrakce na pevné fázi $7 D052616
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Holznerová, Anežka $u The Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského, Czech Republic.
- 700 1_
- $a Solich, Petr $u The Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského, Czech Republic.
- 700 1_
- $a Šatínský, Dalibor $u The Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského, Czech Republic.
- 773 0_
- $w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 40, č. 23 (2017), s. 4599-4609
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28986945 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180709 $b ABA008
- 991 __
- $a 20180710095412 $b ABA008
- 999 __
- $a ok $b bmc $g 1316725 $s 1021515
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 40 $c 23 $d 4599-4609 $e 20171102 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
- LZP __
- $a Pubmed-20180709