Something wrong with this record ?
Uncorrected near visual acuity after monofocal intraocular lens implantation
Ján Lešták, Šárka Pitrová, Martin Fůs, Markéta Žáková
Language English Country Czech Republic
Document type Evaluation Study
- Keywords
- nekorigovaný pooperační vizus do blízka, UNVA, monofokální IOL, pseudo-akomodace,
- MeSH
- Axial Length, Eye MeSH
- Cataract Extraction * MeSH
- Lens Implantation, Intraocular * statistics & numerical data MeSH
- Data Interpretation, Statistical MeSH
- Middle Aged MeSH
- Humans MeSH
- Anterior Chamber MeSH
- Cornea physiology MeSH
- Corneal Topography MeSH
- Aged MeSH
- Statistics as Topic MeSH
- Age Factors MeSH
- Visual Acuity * physiology MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Aged MeSH
- Publication type
- Evaluation Study MeSH
Aim of the study was to evaluate retrospectively selected parameters, which influence the postoperative near visual acuity in a group of pseudophakic eyes of patients with Uncorrected Distance Visual Acuity (UDVA) and according to acquired results establish those, which mostly influenced good Uncorrected Near Visual Acuity (UNVA) after the implantation of monofocal IntraOcular Lens (IOL). Altogether, 122 pseudophakic eyes of 65patients were followed up, out of them in 57 patients both eyes were operated on. The frequency of visual acuity for three groups of operated eyes categorized according to the crucial parameter – eye’s axial length (short, average, long) was evaluated. In each of groups, the average parameters (age, axial length, keratometry, and depth of the anterior chamber) were established, as well as relative frequency of postoperative uncorrected near visual acuity on conventionally used reading tables. The near visual acuity assessment for each eye separately was preformed in its horizontal position using the Zeiss table. The study did not confirm positive correlation of postoperative near visual acuity on the age of the patient, depth of the anterior chamber, nor the implanted IOL type. It was confirmed the presumption of optimal near visual acuity for eyes with axial length shorter than 23.5 mm, and in the process, between both parameters slightly negative correlation was found. On the other hand, middle positive correlation between uncorrected near visual acuity and central corneal power (in dioptres) in eyes with the axial length 22.5 – 23.5 mm was found. The study confirmed, that higher values of the central corneal power (in dioptres) and the high borderline value of the axial length up to 23.5 mm are the condition for optimal postoperative uncorrected near visual acuity after the implantation of monofocal intraocular lens.
Faculty of Biomedical Engineering Czech Technical University Prague
Jan Lešták Clinic Faculty of Biomedical Engineering Czech Technical University Prague
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18031822
- 003
- CZ-PrNML
- 005
- 20181008101643.0
- 007
- cr|cn|
- 008
- 180925s2017 xr cd fs 000 0|eng||
- 009
- AR
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Lešták, Ján, $d 1955- $7 xx0057880 $u Jan Lešták Clinic, Faculty of Biomedical Engineering, Czech Technical University in Prague; Faculty of Biomedical Engineering, Czech Technical University in Prague
- 245 10
- $a Uncorrected near visual acuity after monofocal intraocular lens implantation / $c Ján Lešták, Šárka Pitrová, Martin Fůs, Markéta Žáková
- 520 3_
- $a Aim of the study was to evaluate retrospectively selected parameters, which influence the postoperative near visual acuity in a group of pseudophakic eyes of patients with Uncorrected Distance Visual Acuity (UDVA) and according to acquired results establish those, which mostly influenced good Uncorrected Near Visual Acuity (UNVA) after the implantation of monofocal IntraOcular Lens (IOL). Altogether, 122 pseudophakic eyes of 65patients were followed up, out of them in 57 patients both eyes were operated on. The frequency of visual acuity for three groups of operated eyes categorized according to the crucial parameter – eye’s axial length (short, average, long) was evaluated. In each of groups, the average parameters (age, axial length, keratometry, and depth of the anterior chamber) were established, as well as relative frequency of postoperative uncorrected near visual acuity on conventionally used reading tables. The near visual acuity assessment for each eye separately was preformed in its horizontal position using the Zeiss table. The study did not confirm positive correlation of postoperative near visual acuity on the age of the patient, depth of the anterior chamber, nor the implanted IOL type. It was confirmed the presumption of optimal near visual acuity for eyes with axial length shorter than 23.5 mm, and in the process, between both parameters slightly negative correlation was found. On the other hand, middle positive correlation between uncorrected near visual acuity and central corneal power (in dioptres) in eyes with the axial length 22.5 – 23.5 mm was found. The study confirmed, that higher values of the central corneal power (in dioptres) and the high borderline value of the axial length up to 23.5 mm are the condition for optimal postoperative uncorrected near visual acuity after the implantation of monofocal intraocular lens.
- 650 12
- $a zraková ostrost $x fyziologie $7 D014792
- 650 12
- $a extrakce katarakty $7 D002387
- 650 _2
- $a rohovková topografie $7 D019781
- 650 _2
- $a axiální délka oka $7 D058452
- 650 _2
- $a rohovka $x fyziologie $7 D003315
- 650 _2
- $a věkové faktory $7 D000367
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a přední komora oční $7 D000867
- 650 _2
- $a statistika jako téma $7 D013223
- 650 _2
- $a interpretace statistických dat $7 D003627
- 650 12
- $a implantace nitrooční čočky $x statistika a číselné údaje $7 D019654
- 653 00
- $a nekorigovaný pooperační vizus do blízka
- 653 00
- $a UNVA
- 653 00
- $a monofokální IOL
- 653 00
- $a pseudo-akomodace
- 655 _2
- $a hodnotící studie $7 D023362
- 700 1_
- $a Pitrová, Šárka, $d 1947- $7 mzk2006348964 $u Jan Lešták Clinic, Faculty of Biomedical Engineering, Czech Technical University in Prague
- 700 1_
- $a Fůs, Martin $7 xx0227865 $u Jan Lešták Clinic, Faculty of Biomedical Engineering, Czech Technical University in Prague
- 700 1_
- $a Žáková, Markéta $7 xx0227727 $u Faculty of Biomedical Engineering, Czech Technical University in Prague
- 773 0_
- $t Czech and Slovak Ophthalmology $g Roč. 73, č. 4 (2017), s. 125-131 $w MED00194413
- 856 41
- $u http://www.cs-ophthalmology.cz/en/journal/2017/4/1 $y plný text volně přístupný
- 910 __
- $a ABA008 $b online $y 4 $z 0
- 990 __
- $a 20180925093659 $b ABA008
- 991 __
- $a 20181008102130 $b ABA008
- 999 __
- $a ok $b bmc $g 1336395 $s 1028812
- BAS __
- $a 3 $a 4
- BMC __
- $a 2017 $b 73 $c 4 $d 125-131 $m Czech and Slovak Ophthalmology $x MED00194413
- LZP __
- $a NLK 2018-13/pk