• Something wrong with this record ?

Determination of major phenolic compounds in apples: Part I-Optimization of high-performance liquid chromatography separation with diode array detection

H. Sklenářová, A. Bílková, M. Pechová, P. Chocholouš,

. 2018 ; 41 (15) : 3042-3050. [pub] 20180625

Language English Country Germany

Document type Journal Article

The separation of seven phenolic compounds including gallic acid, chlorogenic acid, epicatechin, quercitrin, rutin, phloridzin, and phloretin present in apple peel and pulp and differing in elution properties has been optimized using high-performance liquid chromatography with diode array detection. Several stationary phases were tested to achieve the efficient separation of phenolic compounds in fruit extracts and C18 was found to be the most efficient. Core-shell and fully porous C18 packings were assessed with respect to the complex composition of the fruit extracts. The developed high-performance liquid chromatography method comprised gradient elution in which mobile phase A was water at pH 2.8 adjusted with acetic acid and B was acetonitrile. The gradient shape was the following: 0 min 95% A/5% B, 2.5 min 85% A/15% B, 12 min 50% A/50% B, 15 min 95% A/5% B. The flow rate was 1 mL/min, injection volume 10 μL, and UV detection at 255, 280, 320, and 365 nm was applied. Our method was validated for both C18 core-shell and fully porous packings. The resolution 6.2-14.8, symmetry 0.99-1.34, peak capacity 18-60, peak area repeatability 0.45-1.00% relative standard deviation, calibration range 0.125-5 mg/mL (0.25-10 mg/mL for chlorogenic acid and rutin), correlation coefficients of calibration curve 0.9976-0.9997, and accuracy evaluated as recovery 95.56-107.54% were determined for the core-shell column.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19000667
003      
CZ-PrNML
005      
20190108130604.0
007      
ta
008      
190107s2018 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/jssc.201800302 $2 doi
035    __
$a (PubMed)29878559
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Sklenářová, Hana $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic.
245    10
$a Determination of major phenolic compounds in apples: Part I-Optimization of high-performance liquid chromatography separation with diode array detection / $c H. Sklenářová, A. Bílková, M. Pechová, P. Chocholouš,
520    9_
$a The separation of seven phenolic compounds including gallic acid, chlorogenic acid, epicatechin, quercitrin, rutin, phloridzin, and phloretin present in apple peel and pulp and differing in elution properties has been optimized using high-performance liquid chromatography with diode array detection. Several stationary phases were tested to achieve the efficient separation of phenolic compounds in fruit extracts and C18 was found to be the most efficient. Core-shell and fully porous C18 packings were assessed with respect to the complex composition of the fruit extracts. The developed high-performance liquid chromatography method comprised gradient elution in which mobile phase A was water at pH 2.8 adjusted with acetic acid and B was acetonitrile. The gradient shape was the following: 0 min 95% A/5% B, 2.5 min 85% A/15% B, 12 min 50% A/50% B, 15 min 95% A/5% B. The flow rate was 1 mL/min, injection volume 10 μL, and UV detection at 255, 280, 320, and 365 nm was applied. Our method was validated for both C18 core-shell and fully porous packings. The resolution 6.2-14.8, symmetry 0.99-1.34, peak capacity 18-60, peak area repeatability 0.45-1.00% relative standard deviation, calibration range 0.125-5 mg/mL (0.25-10 mg/mL for chlorogenic acid and rutin), correlation coefficients of calibration curve 0.9976-0.9997, and accuracy evaluated as recovery 95.56-107.54% were determined for the core-shell column.
650    _2
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    _2
$a Malus $x chemie $7 D027845
650    _2
$a fenoly $x analýza $7 D010636
655    _2
$a časopisecké články $7 D016428
700    1_
$a Bílková, Aneta $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic. Research and Breeding Institute of Pomology Holovousy Ltd., Hořice, Czech Republic.
700    1_
$a Pechová, Martina $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic.
700    1_
$a Chocholouš, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Hradec Králové, Czech Republic.
773    0_
$w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 41, č. 15 (2018), s. 3042-3050
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29878559 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190107 $b ABA008
991    __
$a 20190108130805 $b ABA008
999    __
$a ok $b bmc $g 1364702 $s 1038790
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 41 $c 15 $d 3042-3050 $e 20180625 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
LZP    __
$a Pubmed-20190107

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...