• Something wrong with this record ?

A comparison of quality parameters of fresh feline ejaculates collected by three different collection techniques

K. Jelinkova, R. Vitasek, R. Novotny, A. Bartoskova,

. 2018 ; 53 (5) : 1068-1074. [pub] 20180521

Language English Country Germany

Document type Comparative Study, Journal Article

The aim of our study was to compare the quality parameters of fresh feline ejaculates collected by three different techniques-urethral catheterization after medetomidine administration (CT), electroejaculation (EE) and epididymal slicing after orchiectomy (EP). A total of 34 adult male cats (Felis catus) were included in the study. In all male cats, the sperm collection was performed under general anaesthesia by three collection methods in the following order: urethral catheterization, electroejaculation and epididymal slicing. The sperm parameters evaluated were as follows: volume, motility, viability, sperm concentration, total sperm count and morphological examination. The highest quality semen parameters were achieved using EE. The comparison of results of the evaluated sperm quality parameters from EE and EP showed significant differences only in one case-the percentage of head abnormalities and lower percentage of head abnormalities were achieved using EE compared to EP: 8.5% (3.0%-21.0%) versus 10.0% (4.0%-22.0%). Semen collected by CT rendered the lowest quality samples when compared to sperm samples collected by EE and EP, especially with respect to the motility and total sperm count which were significantly lower (p < 0.001). Our study showed that sperm samples collected by EE and EP result in better quality of feline ejaculates compared to collection by CT from sperm samples collected from the same male cats. These results demonstrate the necessity of further research of urethral catheterization as a novel technique of semen collection in male cats.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19000720
003      
CZ-PrNML
005      
20190115123129.0
007      
ta
008      
190107s2018 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1111/rda.13205 $2 doi
035    __
$a (PubMed)29782062
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Jelinkova, Klara $u Department of Reproduction, Small Animal Clinic, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic.
245    12
$a A comparison of quality parameters of fresh feline ejaculates collected by three different collection techniques / $c K. Jelinkova, R. Vitasek, R. Novotny, A. Bartoskova,
520    9_
$a The aim of our study was to compare the quality parameters of fresh feline ejaculates collected by three different techniques-urethral catheterization after medetomidine administration (CT), electroejaculation (EE) and epididymal slicing after orchiectomy (EP). A total of 34 adult male cats (Felis catus) were included in the study. In all male cats, the sperm collection was performed under general anaesthesia by three collection methods in the following order: urethral catheterization, electroejaculation and epididymal slicing. The sperm parameters evaluated were as follows: volume, motility, viability, sperm concentration, total sperm count and morphological examination. The highest quality semen parameters were achieved using EE. The comparison of results of the evaluated sperm quality parameters from EE and EP showed significant differences only in one case-the percentage of head abnormalities and lower percentage of head abnormalities were achieved using EE compared to EP: 8.5% (3.0%-21.0%) versus 10.0% (4.0%-22.0%). Semen collected by CT rendered the lowest quality samples when compared to sperm samples collected by EE and EP, especially with respect to the motility and total sperm count which were significantly lower (p < 0.001). Our study showed that sperm samples collected by EE and EP result in better quality of feline ejaculates compared to collection by CT from sperm samples collected from the same male cats. These results demonstrate the necessity of further research of urethral catheterization as a novel technique of semen collection in male cats.
650    _2
$a zvířata $7 D000818
650    _2
$a kočky $7 D002415
650    _2
$a kryoprezervace $x veterinární $7 D015925
650    12
$a ejakulace $7 D004542
650    12
$a elektrická stimulace $7 D004558
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a medetomidin $x farmakologie $7 D020926
650    _2
$a orchiektomie $x veterinární $7 D009919
650    _2
$a analýza spermatu $x veterinární $7 D055101
650    _2
$a uchování spermatu $x veterinární $7 D012662
650    _2
$a odběr biologického vzorku $x veterinární $7 D013048
650    _2
$a katetrizace močového měchýře $x veterinární $7 D014546
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Vitasek, Roman $u Department of Reproduction, Small Animal Clinic, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic.
700    1_
$a Novotny, Robert $u Department of Reproduction, Ruminant and Swine Clinic, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic.
700    1_
$a Bartoskova, Alena $u Institute of Life-Long Education, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic.
773    0_
$w MED00007347 $t Reproduction in domestic animals Zuchthygiene $x 1439-0531 $g Roč. 53, č. 5 (2018), s. 1068-1074
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29782062 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190107 $b ABA008
991    __
$a 20190115123339 $b ABA008
999    __
$a ok $b bmc $g 1364739 $s 1038843
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 53 $c 5 $d 1068-1074 $e 20180521 $i 1439-0531 $m Reproduction in domestic animals $n Reprod Domest Anim $x MED00007347
LZP    __
$a Pubmed-20190107

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...