-
Something wrong with this record ?
Gait analysis before and after cycle training using a 3D pedal system [Analýza chůze před a po tréninku na bicyklu vybaveném 3D Pedalsystémem]
T. Zippelius, K. Sander, F. Layher, J. Töpfer, G. Matziolis
Language English Country Czech Republic
Document type Journal Article
PubMed
30257760
Knihovny.cz E-resources
- MeSH
- Gait Analysis methods MeSH
- Biomechanical Phenomena MeSH
- Exercise physiology MeSH
- Computer-Aided Design MeSH
- Adult MeSH
- Knee Joint physiopathology MeSH
- Humans MeSH
- Pilot Projects MeSH
- Plyometric Exercise methods MeSH
- Prospective Studies MeSH
- Range of Motion, Articular MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
PURPOSE OF THE STUDY In this pilot study, gait analysis was performed before and after training with a 3D pedal system (BIUS1), in order to clarify whether these differences are detectable by gait analysis after a short period of training. MATERIAL AND METHODS Two female and three male subjects were included in a prospective case-control pilot study. The patient and training characteristics were determined. Objective measurement data of the gait were obtained by using a three-dimensional motion analysis system with six infrared cameras and three force plates before and after training with the 3D pedal system. RESULTS The mean age was 36.7 ± 8.7 years and the subjects had a BMI of 21.8 ± 2.4 kg/m 2 . The training time per year was an average of 36.0 ± 11.2 days, with a training workload of 511.4 ± 36.7 km. For time-distance parameters, improvements for the left and right side were obtained for cadence and cycle time after training. In total, there was a reduction in hip abduction angle, and an increase in hip inward rotation, knee outward rotation, and range of the frontal knee angle. CONCLUSIONS Changes in parameters in the gait analysis after a short training interval demonstrate that a 3D pedal system is suitable to produce changes in the gait pattern detectable by gait analysis. Training effects on the supposedly weaker left side can be explained after a brief application of the BIUS1 system. Key words:cycle training, 3D pedal system, gait analysis.
Analýza chůze před a po tréninku na bicyklu vybaveném 3D Pedalsystémem
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19002871
- 003
- CZ-PrNML
- 005
- 20200121144206.0
- 007
- ta
- 008
- 190116s2018 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $2 doi $a 10.55095/achot2018/049
- 035 __
- $a (PubMed)30257760
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Zippelius, T. $u Orthopaedic Department, Jena University Hospital, Campus Eisenberg, Eisenberg, Germany
- 245 10
- $a Gait analysis before and after cycle training using a 3D pedal system / $c T. Zippelius, K. Sander, F. Layher, J. Töpfer, G. Matziolis
- 246 31
- $a Analýza chůze před a po tréninku na bicyklu vybaveném 3D Pedalsystémem
- 520 9_
- $a PURPOSE OF THE STUDY In this pilot study, gait analysis was performed before and after training with a 3D pedal system (BIUS1), in order to clarify whether these differences are detectable by gait analysis after a short period of training. MATERIAL AND METHODS Two female and three male subjects were included in a prospective case-control pilot study. The patient and training characteristics were determined. Objective measurement data of the gait were obtained by using a three-dimensional motion analysis system with six infrared cameras and three force plates before and after training with the 3D pedal system. RESULTS The mean age was 36.7 ± 8.7 years and the subjects had a BMI of 21.8 ± 2.4 kg/m 2 . The training time per year was an average of 36.0 ± 11.2 days, with a training workload of 511.4 ± 36.7 km. For time-distance parameters, improvements for the left and right side were obtained for cadence and cycle time after training. In total, there was a reduction in hip abduction angle, and an increase in hip inward rotation, knee outward rotation, and range of the frontal knee angle. CONCLUSIONS Changes in parameters in the gait analysis after a short training interval demonstrate that a 3D pedal system is suitable to produce changes in the gait pattern detectable by gait analysis. Training effects on the supposedly weaker left side can be explained after a brief application of the BIUS1 system. Key words:cycle training, 3D pedal system, gait analysis.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a design s pomocí počítače $7 D017076
- 650 _2
- $a cvičení $x fyziologie $7 D015444
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a analýza chůze $x metody $7 D000077107
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a kolenní kloub $x patofyziologie $7 D007719
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a pilotní projekty $7 D010865
- 650 _2
- $a plyometrická cvičení $x metody $7 D059385
- 650 _2
- $a prospektivní studie $7 D011446
- 650 _2
- $a rozsah kloubních pohybů $7 D016059
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Sander, K. $u Orthopaedic Department, Jena University Hospital, Campus Eisenberg, Eisenberg, Germany
- 700 1_
- $a Layher, F. $u Orthopaedic Department, Jena University Hospital, Campus Eisenberg, Eisenberg, Germany
- 700 1_
- $a Töpfer, J. $u BioConform GmbH, Jena, Germany
- 700 1_
- $a Matziolis, G. $u Orthopaedic Department, Jena University Hospital, Campus Eisenberg, Eisenberg, Germany
- 773 0_
- $w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 85, č. 4 (2018), s. 281-284
- 910 __
- $a ABA008 $b A 8 $c 507 $y 4 $z 0
- 990 __
- $a 20190116 $b ABA008
- 991 __
- $a 20200121144543 $b ABA008
- 999 __
- $a ok $b bmc $g 1373941 $s 1041029
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 85 $c 4 $d 281-284 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
- LZP __
- $b NLK118 $a Pubmed-20190116