In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring

J. Seidlerová, J. Gelžinský, M. Mateřánková, J. Ceral, P. König, J. Filipovský,

. 2018 ; 27 (5) : 256-261. [pub] 20180322

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu srovnávací studie, časopisecké články, multicentrická studie, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc19012766

AIMS: Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. MATERIAL AND METHODS: Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. RESULTS: Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). CONCLUSIONS: Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19012766
003      
CZ-PrNML
005      
20200110075353.0
007      
ta
008      
190405s2018 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1080/08037051.2018.1454258 $2 doi
035    __
$a (PubMed)29566565
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Seidlerová, Jitka $u a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Hradec Králové , Czech Republic. b Biomedical Centre, Faculty of Medicine in Pilsen , Charles University , Hradec Králové , Czech Republic.
245    10
$a In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring / $c J. Seidlerová, J. Gelžinský, M. Mateřánková, J. Ceral, P. König, J. Filipovský,
520    9_
$a AIMS: Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. MATERIAL AND METHODS: Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. RESULTS: Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). CONCLUSIONS: Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a měření krevního tlaku $x metody $7 D001795
650    _2
$a ambulantní monitorování krevního tlaku $x metody $7 D018660
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a hypertenze $7 D006973
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a syndrom bílého pláště $x diagnóza $x patofyziologie $7 D059466
651    _2
$a Československo $7 D003604
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a multicentrická studie $7 D016448
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Gelžinský, Julius $u a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Hradec Králové , Czech Republic.
700    1_
$a Mateřánková, Markéta $u a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Hradec Králové , Czech Republic.
700    1_
$a Ceral, Jiří $u c Department of Cardiology , Faculty hospital Hradec Králové , Hradec Králové , Czech Republic.
700    1_
$a König, Petr $7 xx0243659 $u Internal Department II, Faculty of Medicine in Pilsen , Charles University , Hradec Králové , Czech Republic.
700    1_
$a Filipovský, Jan $u a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Hradec Králové , Czech Republic. b Biomedical Centre, Faculty of Medicine in Pilsen , Charles University , Hradec Králové , Czech Republic.
773    0_
$w MED00000810 $t Blood pressure $x 1651-1999 $g Roč. 27, č. 5 (2018), s. 256-261
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29566565 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190405 $b ABA008
991    __
$a 20200110075723 $b ABA008
999    __
$a ok $b bmc $g 1392076 $s 1051071
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 27 $c 5 $d 256-261 $e 20180322 $i 1651-1999 $m Blood pressure $n Blood Press $x MED00000810
LZP    __
$a Pubmed-20190405

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...